以逆設計法提升風機去渦流導葉性能
Improving the Performance of Fan Deswirl Vanes by Inverse Design Method
摘要
風機屬將機械能轉化為流體之壓力與動能的加壓裝置,而加壓後之高速氣流具渦漩特性(swirling flow),造成出口處有高比例之切線速度壓(動壓)處於浪費,因此可於葉輪出口下游處增設去渦流導葉(deswirl vane)裝置,達到提升壓力與改善流場穩定性之效益。傳統去渦流導葉設計上,因無法確定風機內流場狀況,多採線形繪製與模擬方式進行設計與優化,需耗費大量繁複分析與修改程序,設計時間冗長,屬正向設計法(direct design method)。本研究係導入壓縮機之逆向設計(inverse design method)方法,建置去渦流導葉改善風機導葉與回流系統之性能,逆向設計法其特點於設計葉形來至預設流場之流線,可明確掌控流場之速度分佈與葉片負載,較以往正向設計法更符合於實際流體流動狀態,具較佳的設計結果,更可大幅節省設計時間。
本研究嘗試以混流式風機與雙級離心式高壓風機為載具,係採逆向設計法建構風機之二維與三維去渦流導葉幾何技術,透過實際開發程序得驗證可行性(規格擬定→設計→模擬→製造→驗證→成效評估),以提升風機性能與效率為標的。混流式風機結果顯示,切線速度與流動分離區域大小成正比,有、無導葉流場模擬之全效率減損降幅比率高達83%( 42.3%→7.15%)。另提出殼輪比(RC/R2)設計概念,配合逆向設計法建構,混流式風機實測效率值達76% (B導葉),若殼輪比(Rc/R2)比值大於1.46去渦流導葉(C導葉)可完全回收切線速度,其模擬效率更可提升至81%;雙級離心式高壓風機方面,流體入流角(α2)為具影響回流系統的性能參數,建議高壓風機入流角(α2)為15度且壓力係數(Cθ2/U2)為0.46時有最佳效率,去渦流導葉之葉片數建議為12片,葉片數亦會影響上游的流場分佈,故回流系統設計時應考量整體匹配性,雙級離心式高壓風機實機測試效率值達74.9%。
透過相關研究分析與開發程序驗證,逆向設計法可清楚呈現相關參數改變對葉片負載之影響,茲為判別設計優劣之準則依據,故較傳統正向設計方式更具改善流場穩定性與時效性。透過混流式風機與雙級離心式高壓風機兩款產品經模擬與測試證實達到足夠準確性,其能效分別超越現行國際大廠同款規格約10%(Greenheck67%)與4%(Flakt-Woods 70.5%),藉此相關研究結論與建議,提供對流場相關設計參數有足夠之瞭解與掌握性,茲為開發高效流體機械設計之參卓,協助風機性能提升。
本研究嘗試以混流式風機與雙級離心式高壓風機為載具,係採逆向設計法建構風機之二維與三維去渦流導葉幾何技術,透過實際開發程序得驗證可行性(規格擬定→設計→模擬→製造→驗證→成效評估),以提升風機性能與效率為標的。混流式風機結果顯示,切線速度與流動分離區域大小成正比,有、無導葉流場模擬之全效率減損降幅比率高達83%( 42.3%→7.15%)。另提出殼輪比(RC/R2)設計概念,配合逆向設計法建構,混流式風機實測效率值達76% (B導葉),若殼輪比(Rc/R2)比值大於1.46去渦流導葉(C導葉)可完全回收切線速度,其模擬效率更可提升至81%;雙級離心式高壓風機方面,流體入流角(α2)為具影響回流系統的性能參數,建議高壓風機入流角(α2)為15度且壓力係數(Cθ2/U2)為0.46時有最佳效率,去渦流導葉之葉片數建議為12片,葉片數亦會影響上游的流場分佈,故回流系統設計時應考量整體匹配性,雙級離心式高壓風機實機測試效率值達74.9%。
透過相關研究分析與開發程序驗證,逆向設計法可清楚呈現相關參數改變對葉片負載之影響,茲為判別設計優劣之準則依據,故較傳統正向設計方式更具改善流場穩定性與時效性。透過混流式風機與雙級離心式高壓風機兩款產品經模擬與測試證實達到足夠準確性,其能效分別超越現行國際大廠同款規格約10%(Greenheck67%)與4%(Flakt-Woods 70.5%),藉此相關研究結論與建議,提供對流場相關設計參數有足夠之瞭解與掌握性,茲為開發高效流體機械設計之參卓,協助風機性能提升。
Fan, a mechanism for fluid compressing, is capable to transfer the mechanical energy to the static pressure and kinetic energy of fluid. However, the pressurized fluid with high velocity may cause swirling flow, which leads to the loss of tangential kinetic energy and low compressing efficiency. Therefore, the deswirl vane, a device that equipped at the outlet of the fan, has been proposed to improve the stability of the flow field to further enhance the compressing efficiency. Traditionally, it is hard to design the deswirl vane properly due to the uncertainty of the flow field inside the fan. Thus simulation is usually performed during designing and optimizing, which needs complicating analysis and massive modifications. This methodology is named as the direct design method. In this research, an inverse designing method is performed to design deswirl vanes to improve the reflow system. With the determined flow velocity distribution and vane loading, the vane geometry can be designed inversely. The inversely designed deswirl vane fits more properly to the real flow field and save more labor than direct design method.
This research consider the mix-flow fan and two-stage high-pressure centrifugal fan as design and application targets with the adopted inverse design method. The whole developing process (including specification setting, design, simulation, prototyping, verification, performance evaluation) is performed to verify the feasibility of enhancing the efficiency and performance of fans. The testing result of mix-flow fan shows that the tangential velocity is positively proportional to the area of flow separation. The total efficiency decrement caused by the developed deswirl vane is found to be 83%. With the proposed design concept of shell-vane diameter ratio (RC/R2), the measured efficiency of mix-flow fan is found to be 76% (with deswirl vane B). Once the RC/R2 exceeds 1.46, the deswirl vane C is found to completely recycle the tangential velocity, as a result, the efficiency further reaches 81% in simulation. For the two-stage high-pressure centrifugal fan, the fluid inlet angle (α2) is recommended to be 15 degrees with pressuring coefficient (Cθ2/U2) 0.46 to output optimized efficiency. Considering the matching of reflow system, the number of deswirl vane is recommended to be 12.The measured efficiency of the developed two-stage high-pressure centrifugal fan is found to reach 74.9%.
Through the analysis and practical development, the reverse design method is verified to be a powerful and labor-saving tool compared to direct design method. The two developed fans, mixed-flow and two-statge high-pressure fans, are found to own 10% and 4% efficiency-lead compared to international fans,Greenheck(67%)and Flakt-Woods(70.5%),respectively.Therefore, the successfully developed method and practically performed research work provide a designing guide for the development of deswirl vanes for high-performance fans.
This research consider the mix-flow fan and two-stage high-pressure centrifugal fan as design and application targets with the adopted inverse design method. The whole developing process (including specification setting, design, simulation, prototyping, verification, performance evaluation) is performed to verify the feasibility of enhancing the efficiency and performance of fans. The testing result of mix-flow fan shows that the tangential velocity is positively proportional to the area of flow separation. The total efficiency decrement caused by the developed deswirl vane is found to be 83%. With the proposed design concept of shell-vane diameter ratio (RC/R2), the measured efficiency of mix-flow fan is found to be 76% (with deswirl vane B). Once the RC/R2 exceeds 1.46, the deswirl vane C is found to completely recycle the tangential velocity, as a result, the efficiency further reaches 81% in simulation. For the two-stage high-pressure centrifugal fan, the fluid inlet angle (α2) is recommended to be 15 degrees with pressuring coefficient (Cθ2/U2) 0.46 to output optimized efficiency. Considering the matching of reflow system, the number of deswirl vane is recommended to be 12.The measured efficiency of the developed two-stage high-pressure centrifugal fan is found to reach 74.9%.
Through the analysis and practical development, the reverse design method is verified to be a powerful and labor-saving tool compared to direct design method. The two developed fans, mixed-flow and two-statge high-pressure fans, are found to own 10% and 4% efficiency-lead compared to international fans,Greenheck(67%)and Flakt-Woods(70.5%),respectively.Therefore, the successfully developed method and practically performed research work provide a designing guide for the development of deswirl vanes for high-performance fans.