利用高介電背板提升常壓電漿輔助晶片接合效率
High-Permittivity Backplate for Enhancing the Efficiency of APPJ-Assisted Bonding on Microfluidic Chip
摘要
本研究提出利用高介電常數的背板增強電漿輔助接合微流體晶片的效率。晶片接合是微流體晶片製作中的重要步驟之一,在現有晶片接合中,電漿接合因具良好的接合強度和長期耐用性等優點,是常使用的晶片接合方法。因此本研究提出一個提高電漿接合晶片效率的方法,預計未來在進行大規模生產微流體晶片時,能夠有效地降低生產成本。本研究共分為兩部分,第一部份為探討不同介電背板對常壓電漿束外觀特徵和電性的影響,第二部分為探討不同介電背板對電漿親水性改質的影響,並進行電漿輔助微流體晶片接合,最後比較不同介電背板的電漿接合效率。本研究利用空氣、水和金屬作為介電背板,三種材料的相對介電常數量測值分別為1.97、866.80及無限大。第一部分實驗結果顯示,隨介電背板的相對介電常數增加,常壓電漿束的亮度以及晶片表面的電離波寬度會隨之提升,顯示電漿強度及處理範圍可透過背板介電常數調控。從電漿束的電性結果顯示,改變介電背板對常壓電漿束的功率無固定的趨勢變化,且變化幅度在10 %內。第二部分的結果顯示,在3.5 kV輸出電壓下,高介電背板有較佳的親水性改質效果,以空氣、水和金屬為介電背板處理的晶片表面接觸角分別為71.58 ˚、54.13 ˚和33.95 ˚。從電漿輔助晶片接合實驗的結果顯示金屬介電背板具有最大的電漿接合強度,接合強度值為235.67 kPa。電漿接合效率的結果顯示,金屬背板具有最佳的電漿晶片接合效率,接合效率值為3.22 kPa/J,相較空氣和水介電背板,接合效率分別提升 72.20 %和20.98 %。
This research proposes the use of high-permittivity backplates to enhance the efficiency of plasma-assisted bonding of microfluidic chips. Chip bonding is a crucial step in microfluidic chip fabrication. This study presents a method to improve the efficiency of plasma bonding for microfluidic chips, with the aim of effectively reducing production costs on a large scale. The research is divided into two parts. The first part explores the influence of different permittivity backplates on the appearance and electrical properties of plasma. The second part investigates the impact of different backplates on surface modification and bonding along with discussions on bonding efficiency. Three materials are used as backplates in the study, and they are air, water, and metal, with their relative dielectric constants being 1.97, 866.80, and infinity, respectively. The experimental results show that as the relative dielectric constant of the backplate increases, the brightness of the plasma and the width of ionization wave on the chip surface also increase, while the electrical properties exhibit no fixed trend with fluctuations within 10%. The results indicate that the plasma intensity and treatment range can be regulated by different backplate. In the second part, it is observed that the high-permittivity backplate has a better hydrophilicity modification. The average contact angles on the surfaces treated with air, water, and metal as the backplates are 71.58°, 54.13°, and 33.95°, respectively. The results from the chip bonding experiments indicate that the metal backplate has the highest plasma bonding strength, with a value of 235.67 kPa and the best bonding efficiency, with a value of 3.22 kPa/J, representing 72.20% and 20.98% increase compared to the air and water backplates, respectively.