下顎長跨距缺損治療普遍使用自體骨移植手術搭配重建骨釘骨板系統進行手術。根據文獻指出種族與下顎骨外型上具差異性,因此下顎缺損重建治療仍普遍使用傳統制式重建骨板針對不同患者下顎外型進行調整,預彎折骨板適配性效果仍然有限,且反覆彎折容易在彎折處產生金屬疲勞現象而產生破壞,並增加手術時間、提高手術感染風險。
本研究透過臺北榮民總醫院人體試驗委員會(IRB),該計畫編號為215-02-005BC,篩選代表性下顎骨進行研究,藉由電腦模擬分析模擬自體骨移植手術於下顎頦端缺損並分別針對傳統重建骨板及三種新型制式重建骨板(第一~三代),分別為第一代新型制式重建骨板,該設計為不連續之倒U型外型設計,可使移植骨固定於下顎齒槽部位;第二代新型制式重建骨板,該設計保留倒U型外型設計,並於頦隆凸處增加橫桿加強強度;第三代新型制式重建骨板,該設計為殘骨之固定螺孔交錯排列,並增加中段補骨不同高度之移植骨選擇性等四種不同外型設計之骨板固定狀態下進行負載模擬分析。處此之外,開發預製化彎折技術,該技術整合醫學影像重組技術、逆向工程技術、電腦輔助設計和快速成形技術等製作模具,並藉由沖壓機台及模具透過沖壓彎折使新型制式重建骨板沖壓成形為具下顎外型曲率之預成形骨板,接著透過體外實驗之ASTM F382與ASTM F543分別驗證新型制式重建骨板與新式固鎖式骨釘之靜態力學強度,並將沖壓朔型後之預成形骨板進行疲勞負載驗證其疲勞強度。
由分析結果顯示,傳統重建骨板、第一代新型制式重建骨板、第二代新型制式重建骨板、第三代新型制式重建骨板之最大應力分別為546 MPa、116 MPa、21 MPa、197 MPa。ASTM F382骨板力學測試結果顯示,傳統重建骨板之彎曲勁度、結構勁度與彎曲強度分別為744.75 N/mm、1305878.76 N-mm2、5280 N-mm;第三代新型制式重建骨板之彎曲勁度、結構勁度與彎曲強度分別為1911.97 N/mm、2186019.04 N-mm2、7396.67 N-mm。疲勞負載測試結果顯示,傳統重建
骨板與預成形骨板皆通過二十萬次循環負載。整體而言,第三代新型制式重建骨板之設計改變既有傳統重建骨板之補骨移植位置僅能施打於頦隆凸,造成術後齒槽高低不齊而影響人工牙根植入困難之問題;且相較於傳統重建骨釘骨板系統,新型制式重建骨釘骨板系統有較好力學表現,其所搭配之預成形技術能大幅度減少彎折時間,除此之外,相較於手動彎折,預成形技術能達到更好的適配性且骨板依舊能維持足夠的穩定性,確保半年內之疲勞負載下仍維持其力學強度。
The free flap surgery is considered as the gold standard method for reconstruction of the mandibular defect. However, shapes of the mandible contour are different from ethnicity. Therefore, traditional reconstruction plate most be bent to fix the shapes of the mandible contour,but it’s hard to be in contact with the bone to maintain stability. In the literature, MatrixMANDIBLE Preformed Reconstruction Plates seem to be a useful standard device in a scope of indications for load-bearing osteosynthesis of mandibular defect, additionally facilitating a transoral approach for application,but that it’s has limited effects for plate adaptation . In the literature, when this stress repeated many times, the strength of the material may be drastically reduced and ultimately cause failure.

This study used combined CAD/CAE techniques to establish FE models of the mandibular symphysis defect with bone graft treatment, fixed with three new and one traditional reconstruction plates were generated using computed-tomography image stacking and computer-aided design technique. New reconstruction plates were designed including the first type which can fix bone graft in alveolar process to avoid injury of nervous and rooted tooth, and the second type which can fix bone graft similar to the first type but strength the base portion in the bone plate to improve the biomechanical performance, and the other was the third type which can fix bone graft similar to the second type. In addition, the third type can be used in different altitude of alveoli dentales. The new reconstruction plates were stamped by punch with mold which were established by CAD techniques and image processing technique. Stress values and corresponding concentration regions of traditional, the first, the second, and the third reconstruction plates in different bone healing stages after surgery under receiving occlusal force were noted by performing non-linear FE analyses. After manufacturing the new reconstruction plates we conducted functional tests to confirm the efficacy and safety of the proposed the new reconstruction plates. Three functional system tests were conducted, screw test (ASTM F543), bone plate test (ASTM F382), fatigue test.
Simulated results demonstrated that the maximum stress of traditional, RU, ERU and the new reconstruction plate were 546, 116, 21 and 197 MPa. ASTM F382 test results demonstrated that bending stiffness, bending structural stiffness and bending strength of traditional reconstruction plate were 744.75 N/mm、1305878.76 N-mm2、5280 N-mm;bending stiffness, bending structural stiffness and bending strength of the new reconstruction plates were 1911.97 N/mm、2186019.04 N-mm2、7396.67 N-mm. Fatigue test results demonstrated that both traditional reconstruction plate and the new reconstruction plate were achieved the request of 200000 tests cyclic.In conclusion, New reconstruction plate with preformed techniques can fix bone graft in alveolar process to avoid of injury of nervous and rooted tooth and enhanced structural stability can restore occlusal function in mandibular symphysis defect.