既有地下結構物對基地抽水洩降之影響

Effect of Existing Underground Structures on Dewatering Drawdown at Excavation Sites

檔案

日期

2023

類型

語言

中文

摘要

近年來,許多開挖基地發生了坍塌事件,並導致周圍地層出現下陷現象,同時也造成附近民宅和建築物受到損害。後續調查發現可能與地下水抽水作業相關。不僅如此基地周圍既有大樓或捷運站體等地下結構物可能會對抽水作業產生影響,這些結構物可能形成屏障效應,阻礙地下水的自由流動,進而導致地下水位洩降變得複雜且難以預測。過去相關的評估和研究再這方面相對較少,然而,隨著更多類似事件的發生對於地下工程的持續發展,需要深入研究這些問題,以確保未來的開挖工程能夠更加安全和穩定地進行。本研究藉由GMS MODFLOW內建的多節點井2 (MNW2)套件結合MODFLOW-NWT處理程序進行抽水模擬,透過改變抽水井設定,以及更改模型大部分土壤的導水度和調整開挖基地與地下結構物之間相對距離,探討不同條件下對基地內外水位洩降的影響。根據研究結果顯示,抽水方案對水位洩降影響有限,導水度較高的土層中會加強抽水方案的水位洩降影響,反之則減少。若導水度太小甚至導致所有的抽水方案水位洩降一致,抽水方案的影響幾乎消失。另一方面,當基地與地下結構物之間距離越遠,有地下結構物側水位洩降減少,無地下結構物側則在距離30公尺附近時有最大洩降速率。
In recent years, there have been several incidents of collapse at excavation sites caused by groundwater pumping operations. These incidents have the potential to result in subsidence in the surrounding soil layers and damage to nearby buildings. Additionally, the presence of pre-existing underground structures, such as high-rise buildings and MRT stations, in the vicinity of these sites may impact pumping activities. This can potentially create a barrier effect that hinders the free movement of groundwater. This phenomenon leads to complex and unpredictable patterns of groundwater level depletion. There has been relatively little assessment and research on this issue in the past, but with more similar incidents occurring, further study is needed to ensure the safety and stability of future excavation projects.
The purpose of this study is to investigate the effect of various conditions on drawdown, both within and outside the excavation side. The study employs the MNW2 package, which is integrated with the MODFLOW-NWT computational approach in GMS MODFLOW software, to simulate different pumping scenarios. It explores the effects of different pumping well configurations, changes in soil permeability, and adjustments to the relative distance between the excavation site and underground structures on groundwater level drawdown.The results of analysis reveal that the influence of groundwater level drawdown is permeability greater than pumping schemes. Higher permeability layers enhance the impact, while lower permeability layers reduce it. If the permeability is too low, the impact of pumping schemes almost disappears. On the other hand, the farther the distance between the excavation site and underground structures, the less drawdown occurs on the side of the structures. The maximum drawdown rate occurs at a distance of around 30 meters when there are no underground structures.

所屬典藏

土木工程學系
顯示完整詮釋資料 統計資料

引用此條目

邵大維 (2023). 既有地下結構物對基地抽水洩降之影響. https://thesis.lib.nycu.edu.tw/handle/20.500.14371/641

BibTeX RIS

引用文字依 APA 第 7 版格式自動產生,使用前請再核對。

分享

永久網址:https://thesis.lib.nycu.edu.tw/handle/20.500.14371/641