波向量編碼微小化雙光子螢光顯微鏡
顯示簡易詮釋資料 統計資料| 欄位 | 內容 | 語言 |
|---|---|---|
dc.contributor.advisor |
詹明哲 | |
dc.contributor.advisor |
Chan, Ming-Che | |
dc.contributor.author |
蔡柏霖 | |
dc.contributor.author |
Tsai, Bo-Lin | |
dc.contributor.college |
光電學院 | |
dc.contributor.committee |
曾盛豪 | |
dc.contributor.committee |
林碩泰 | |
dc.contributor.committee |
卓冠宇 | |
dc.contributor.committee |
Tseng, Sheng-Hao | |
dc.contributor.committee |
Lin, Shou-Tai | |
dc.contributor.committee |
Zhuo, Guan-Yu | |
dc.contributor.department |
照明與能源光電研究所 | |
dc.contributor.studentid |
0358102 | |
dc.date.NCLavailable |
2021/11/17 | |
dc.date.USTavailable |
2021/11/17 | |
dc.date.issued |
2016 | |
dc.date.issuedROC |
105 | |
dc.date.schoolyear |
105 | |
dc.description.abstract |
非線性顯微術,是一具三維高解析度的虛擬切片技術,並被廣泛運用在生物、化學以及醫學的研究上。近年來,因為醫療及工業上的需求,發展小型、可攜式、光纖化的非線性顯微鏡是一重要的研究課題。當前存在的微小光纖化非線性顯微鏡研究可分為兩大類,包括遠測掃描式(Distal Scanning)以及近側掃描(Proximal Scanning)機制兩種。目前所需探討的問題為如何有效利用光纖傳遞飛秒雷射和收集樣品的非線性訊號,及如何封裝微小型的的內視鏡探頭,而現存的遠側和近側兩類掃描機制尚且無法完全解決上述根本問題。在本論文中,我們首先提出了一種新穎的波向量編碼雷射掃描內視鏡。此內視鏡是藉由方型光纖傳遞光的波向量函數(其中雷射脈衝經由1公尺的光纖僅展寬1.28倍寬度),並利用LabVIEW程式進行影像索引編碼,最後以1030 nm 飛秒雷射和螢光小球做為光源及樣品端來展示出雙光子螢光內視鏡。 | |
dc.description.abstract |
Nonlinear laser scanning microscopy is a powerful virtual-biopsy tool for performing 3D structural and functional imaging of biological tissues. In recent years, to develop fiber-optic endo-microscopy is an important issue. Current fiber-optic nonlinear laser scanning endo-microscopy can be divided into two categories. One is proximal scanning mechanism by fiber-optic bundles and the other is distal scanning mechanism by packing a miniaturized scanner such as MEMS mirrors and PZT actuators, into the end of the nonlinear endoscope. However, there are three entanglement technical challenges include single-mode beam delivery of femtosecond excitation pulses, efficient collection of nonlinear signals from specimens, and a high-quality beam scanning mechanism within an ultra-compact package. There three challenges cannot be solved with both categories. In this work, we developed a novel design of nonlinear fiber-optic endoscope, a wave-vector-encoded nonlinear laser scanning endo-microscopy. In the endoscope, the wave-vectors of the scanned beams were delivered by a rectangular-shape fiber. Moreover, the pulse broadening ratio in a 1 meter long rectangular-shape fiber was as small as 1.28, which means the two-photon excitation efficiencies can be recovered by the fiber. By the position sensitive detection and a home-made LabVIEW programs, the wave-vectors after the fiber is recovered. Then by the recovered wave-vectors, the two-photon fluorescence microscopy images of fluorescence beads were performed to demonstrate the concept of wave- vector-encoded endoscope. | |
dc.description.abstractopendate |
||
dc.description.degree |
碩士 | |
dc.description.tableofcontents |
摘要.......................................IABSTRACT...................................II誌謝.......................................IV目錄.......................................V表目錄.....................................VIII圖目錄.....................................IX符號說明...................................XIII一、 緒論..................................11.1 前言...................................11.2 研究動機...............................21.3 論文大綱...............................4二、實驗原理與元件.........................52.1 非線性光學.............................52.2雙光子螢光顯微鏡........................62.2.1雙光子螢光顯微鏡之優勢................92.3方形光導纖維............................112.3.1波向量編碼掃描機制....................132.3.2脈衝展寬效應..........................142.4自相關干涉儀(Autocorrelator)............162.5 PSD(Position sensitive detector).......182.5.1 PSD工作原理..........................182.5.2 PSD點位解析度........................202.5.3 位置感測誤差.........................232.5.4 二維PSD..............................242.6光電倍增管..............................27三、實驗架構與流程.........................323.1 鎖模雷射光源...........................323.2 實驗樣品...............................333.3光路架構................................343.4電路架構................................363.5 LabVIEW程式............................373.5.1 LabVIEW編碼流程......................393.5.2 LabVIEW影像擷取流程..................40四、實驗結果與討論.........................424.1 脈衝寬度及頻譜量測.....................424.2 PSD量測雷射光束移動軌跡................454.3螢光微球雙光子影像......................504.4實驗結果討論............................55五、結論與未來展望.........................57參考文獻...................................59 | |
dc.identifier.citation |
[1] R. Hooke, Micrographia: or some physiological descriptions of minute bodies made by magnifying glasses, with observations and inquiries thereupon, Courier Dover Publications, London, 113 (1665).[2] C. Dobell, Antony van Leeuwenhoek and his “Little Animals”; being some account of the father of protozoology and bacteriology and his multifarious discoveries in these disciplines, Harcourt Brace and Company, New York, 37–41 (1932).[3] W. Denk, J. H. Strickler, and W. W. Webb, “Two-photon laser scanning fluorescence microscopy,” Science 248, 73-76 (1990).[4] C. B. Huang, X. J. Peng, Z. Y. Lin, J. L. Fan, A. X. Ren, and D .X. Sun, “A highly selective and sensitive two-photon chemosensor for silver ion derived from 3,9-dithia-6-azaundecane,”Sensors and Actuators B 133,113-117 (2008).[5] B. A. Flusberg, E. D. Cocker, W. Piyawattanametha, J. C. Jung, E. L. M. Cheung and M. J. Schnitzer, “Fiber-optic fluorescence imaging,” Nature Methods 2, 941-950 (2005).[6] W. Piyawattanametha, R. P. J. Barretto, T. H. Ko, B. A. Flusberg, E. D. Cocker, H. Ra, D. Lee, O. Solgaard, and M. J. Schnitzer, “Fast-scanning two-photon fluorescence imaging based on a microelectromechanical systems two- dimensional scanning mirror,” Optics Letters 31, 2018-2020 (2006).[7] T. M. Liu, M. -C. Chan, I. H. Chen, S. H. Chia, and C. K. Sun, “Miniaturized multiphoton microscope with a 24Hz frame-rate,” Optics Express 16, 10501-10506 (2008).[8] L. Liu, E. K. Wang, X. Y. Zhang, W. X. . Liang, X. D. Li, and H. K. Xie, “MEMS-based 3D confocal scanning microendoscope using MEMS scanners for both lateral and axial scan ,” Sensors and Actuators A: Physical 215, 89-95 (2014).[9] L. Liu, E. Wang, X. Zhang, W. Liang, X. Liang, X. Li, and H. Xie, “MEMS-based 3D confocal scanning microscope using MEMS scanners for both lateral axial scan,” Sensors and Actuators A 215, 89-95 (2014).[10] N. Zhang, T. H. Tsai, O. O. Ahsen, K. Liang, H. C. Lee, P. Xue, X. D. Li, and J. G. Fujimoto, “Compact piezoelectric transducer fiber scanning probe for optical coherence tomography ,” Optics Letters 39, 186-188 (2014).[11] Y. Chen, Y. Zang, W. Liang, and X. Li, “Gold nanocages as contrast agents for two-photon luminescence endomicroscopy imaging,” Nanomedicine: Nanotechnology, Biology, and Medicine 8, 1267-1270 (2012).[12] G. J. Tearney, M. E. Brezinski, B. E. Bouma, S. A. Boppart, C. Pitris, J. F. Southern, and J. G. Fujimoto, “In vivo endoscopic optical biopsy with optical coherence tomography,” Science 276, 2037-2039 (1997).[13] B. A. Flusberg, E. D Cocker, W. Piyawattanametha, J. C Jung, E. L M Cheung and M. J Schnitzer, “Fiber-optic fluorescence imaging,” Nature Methods 2, 941-950 (2005).[14] M. C. Chan, S. W. Chu, C. H. Tseng, Y. C. Wen, Y. H. Chen, G. D. Su, and C. K. Sun, “Cr: Forsterite-laser-based fiber-optic nonlinear endoscope with higher efficiencies,” Microscopy Research and Techniques 71, 559-563 (2008).[15] A. V. Oppenheim, A. S. Willsky, and S. Hamid, Signals and Systems, Prentice Hall, New Jersey, (1996).[16] P. A. Franken, A. E Hill, C. W. peter, and G. Weinreich, “Generation of optical harmonics,” Physical Review Letter 7,118-119 (1961).[17] S. Sakadić, U. Demirbas, T. R. Mempel, A. Moore, S. Ruvinskaya, D. A. Boas, A. Sennaroglu, F. X. Kartner, and J. G. Fujimoto, “Multi-photon microscopy with a low-cost and highly efficient Cr: LiCAF laser,” Optics Express 25, 20848-20863 (2008).[18] M. G. Mayer, “Elementary processes with two quantum transitions,” Annalen der Physik 401, 273-294 (1931).[19] W. Kaiser, and C. G. B. Garrett, “Two-photon excitation in CaF2: Eu2+,” Physical Review Letter 7, 229–232 (1961).[20] K. Thomsen, R. Meier, H. Stepp, and R. Sroka, “Development of a confocal and two-photon endomicroscope – preliminary results of qualitative evaluation,” Medical Laser Application 25, 166-172 (2010).[21] P. T. C. So, C. Y. Dong, B. R. Masters, and K. M. Berland, “Two-photon excitation fluorescence microscopy,” Annual Review of Biomedical Engineering 2, 399-429 (2000).[22] R. K. P. Benninger and D. W. Piston, “Two-photon excitation microscopy for the study of living cells and tissues,” Current Protocols in Cell Biology 4, 1-24 (2013).[23] J. M. Squirrell, D. L. Wokosin, J. G. White, and B. D. Bavister, “Long-term two-photon fluorescence imaging of mammalian embryos without compromising viability,” Nature Biotechnology 17, 763-767 (1999).[24] B. R. Masters, P. T. So, E. Gratton, “Multiphoton excitation fluorescence microscopy and spectroscopy of in vivo human skin,” Biophysical Journal 72, 2405-2412 (1997).[25] K. C. Kao, G. A. Hockham, “Dielectric fibre surface waveguide for optical frequencies,” IEE Proceedings 113, 1151-1158 (1966).[26] S. P. Tai, M. C. Chan, T. H. Tsai, S. H. Guo, L. J. Chen, and C. K. Sun, “Two-photon fluorescence microscope with a hollow-core photonic crystal fiber,” Optics Express 12, 6122 (2004).[27] G. Chang, L. J. Chen, and F. X. Kärtner, “Highly efficient Cherenkov radiation in photonic crystal fibers for broadband visible wavelength generation,” Optics Letter 35, 2361 (2010).[28] J. Takayanagi, T. Sugiura, M. Yoshida, and N. Nishizawa, “1.0-1.7- µm wavelength-tunable ultrashort-pulse generation using femtosecond Yb-doped fiber laser and photonic crystal fiber,” IEEE Photonics Technology Letters 18, 2284 (2006).[29] J. P. Gordon, “Theory of the soliton self-frequency shift,” Optics Letter 11, 662–664 (1986).[30] C. Zeng, F. Li, X. D. Xu, “Characterisitics of optoelectronic position sensitive detector and its application,” Optical Instruments 24, 4-5 (2002).[31] 徐照夫,光感測器及使用方法,初版,全華科技圖書,pp189-191,1911。[32] 鄭明哲,光電裝置應用技術,初版,文笙書局,pp86-94,1991。[33] T. H. Huang, H. Lo, C. Lo, M. C. Wu, W. S. Lour, “Static and dynamic properties of a GaAs p-i-n position-sensitive detector (PSD),” Sensors and actuators A: Physical 249, 256-262 (2016). | |
dc.identifier.uri |
https://hdl.handle.net/20.500.14371/64708 | |
dc.language.iso |
中文 | |
dc.relation.alma |
990055616180206772 | |
dc.relation.page |
62 | |
dc.subject.keyword |
雙光子螢光 | |
dc.subject.keyword |
內視鏡 | |
dc.subject.keyword |
位敏感測器 | |
dc.subject.keyword |
方形光纖 | |
dc.subject.keyword |
Two-photon fluorescence | |
dc.subject.keyword |
Endoscopy | |
dc.subject.keyword |
Position sensitive detector | |
dc.subject.keyword |
Ractangular-shape fiber | |
dc.title |
波向量編碼微小化雙光子螢光顯微鏡 | zh-TW |
dc.title |
Two-photon fluorescence endoscopy by wave-vector encoding | en |
dc.type |
Thesis | zh-TW |
檔案
- 01.pdf (2.98 MB, Adobe PDF)
所屬典藏: 照明與能源光電研究所