CsPbBr3量子點不同物相對光電探測器靈敏度影響的比較
Comparison of the effect of CsPbBr3 quantum dots with different phases on photodetector sensitivity
摘要
在技術不斷演進的快速發展環境中,受到人工智慧迅猛進展的推動,智慧生活已牢牢確立為當代的標準。自動駕駛和可穿戴健康設備等應用依賴光作為監控的信號源,導致對光感測器的需求急劇增加。然而,傳統的光感測器在製造過程中通常會產生顯著的污染,這是一個值得關注的問題。因此,本研究選擇專注於鈣鈦礦光感測器。鈣鈦礦光感測器的優勢在於其相對較低的製造過程中污染,相比傳統光感測器,使其成為一個有前景的選擇,特別是在應對現代技術應用中不斷升級的光感測需求方面。這項研究旨在比較鈣鈦礦光感測器中兩種不同相的光電性能,重點是鈣鈦礦結構如何影響電特性。采用熱注入法合成了CsPbBr3量子點(QD)的立方相,而採用另一種方法合成了單斜相。通過UV-Vis、光致發光(PL)、X射線衍射(XRD)和X射線光電子能譜(XPS)分析來驗證成功合成了CsPbBr3 QD。隨後,使用掃描電子顯微鏡(SEM)和原子力顯微鏡(AFM)檢查表面。下一階段涉及確定每層膜的厚度並製作測量設備。為了分析設備的電性能,我們使用B1500儀器,評估暗電流、光電流、響應度(R)、檢測度(D*)、光敏度(P)、開關比和上升/下降時間等參數。最初,我們觀察到在3000轉/分的條件下旋轉的鈣鈦礦層在電性能方面優於1000轉/分的層。此外,單斜相鈣鈦礦在電性能方面優於立方相,這一優勢歸因於其有效地覆蓋了氧化鋅量子點層,促進了電子傳遞。相反,立方相鈣鈦礦觀察到的較短的上升/下降時間是由於電子-空穴對的容易結合,這表現為其較高的發射和較低的外部量子效率(EQE)。
In the rapidly evolving landscape of technological advancements, driven by the rapid evolution of artificial intelligence, smart living has firmly established itself as the contemporary norm. Applications like autonomous driving and wearable health devices rely on light as a signal source for monitoring, leading to a surging demand for light sensors. However, conventional light sensors often generate significant contamination during their manufacturing processes, posing a noteworthy concern. Therefore, this study has chosen to focus on perovskite light sensors. The advantage of perovskite light sensors lies in their relatively lower pollution footprint in the manufacturing process compared to traditional counterparts. This makes perovskite light sensors a promising choice, particularly in addressing the escalating demand for light sensing in modern technological applications.
This research aims to compare the electrical performance of two different phases of perovskites within a perovskite photodetector, with a focus on how the perovskite structure influences electrical characteristics. The cubic phase of CsPbBr3 quantum dots (QDs) was synthesized using the hot-injection method, while the monoclinic phase was produced using an alternative approach. Verification of successful CsPbBr3 QDs synthesis was achieved through UV-Vis, photoluminescence (PL), X-ray diffraction (XRD), and X-ray photoelectron spectroscopy (XPS) analyses. Subsequently, the surfaces were examined using scanning electron microscopy (SEM) and atomic force microscopy (AFM).
The next phase involved confirming the thickness of each film and fabricating the devices for measurement. To analyze the electrical properties of the devices, we employed the B1500 instrument, assessing parameters such as dark current, photocurrent, responsivity (R), detectivity (D*), photosensitivity (P), on-off ratio, and rise/decay time. Initially, we observed that the perovskite layer spun at 3000 rpm exhibited superior electrical characteristics compared to the layer spun at 1000 rpm. Furthermore, it became apparent that the monoclinic phase perovskites outperformed the cubic phase in terms of electrical performance. The improved performance of the monoclinic phase is attributed to its ability to effectively cover the ZnO QDs layer, facilitating electron transport. Conversely, the shorter rise/decay time observed in the cubic phase perovskites is due to the ease of electron-hole pair recombination, as evidenced by its higher emission and lower external quantum efficiency (EQE).
This research aims to compare the electrical performance of two different phases of perovskites within a perovskite photodetector, with a focus on how the perovskite structure influences electrical characteristics. The cubic phase of CsPbBr3 quantum dots (QDs) was synthesized using the hot-injection method, while the monoclinic phase was produced using an alternative approach. Verification of successful CsPbBr3 QDs synthesis was achieved through UV-Vis, photoluminescence (PL), X-ray diffraction (XRD), and X-ray photoelectron spectroscopy (XPS) analyses. Subsequently, the surfaces were examined using scanning electron microscopy (SEM) and atomic force microscopy (AFM).
The next phase involved confirming the thickness of each film and fabricating the devices for measurement. To analyze the electrical properties of the devices, we employed the B1500 instrument, assessing parameters such as dark current, photocurrent, responsivity (R), detectivity (D*), photosensitivity (P), on-off ratio, and rise/decay time. Initially, we observed that the perovskite layer spun at 3000 rpm exhibited superior electrical characteristics compared to the layer spun at 1000 rpm. Furthermore, it became apparent that the monoclinic phase perovskites outperformed the cubic phase in terms of electrical performance. The improved performance of the monoclinic phase is attributed to its ability to effectively cover the ZnO QDs layer, facilitating electron transport. Conversely, the shorter rise/decay time observed in the cubic phase perovskites is due to the ease of electron-hole pair recombination, as evidenced by its higher emission and lower external quantum efficiency (EQE).