摘要

隨着互補式金屬半導體積體電路製程的進步,功能日益複雜的積體電路(Integrated Circuits, ICs)得以廣泛應用於微電子產品中。在多樣的使用環境下,基於可控環境的元件層級靜電放電 (Component-Level ESD) 保護,已經無法確保積體電路在實際應用中的可靠度。因此針對終端用戶的系統層級靜電放電(System-Level ESD)以及電性快速脈衝(Electrical Fast Transient)防護在半導體積體電路的可靠度設計中越來越受到重視。在相應的靜電放電規範(IEC 61000-4-2 and IEC 61000-4-4)定義的測試條件下,由靜電放電電壓引起的快速暫態雜訊會隨機耦合到微電子產品的電源、接地、輸入/輸出腳位上,從而引發產品不正常工作,甚至損毀。針對系統層級靜電放電的防護,傳統的解決方法是在微電子產品的印刷電路板上增加抑制暫態雜訊的離散元件,如暫態突波抑制器(Transient Voltage Suppressor)及板上雜訊濾波網絡(Board-level Noise Filter Network)等。然而板級的解決方案會大幅增加微電子產品的製造成本。因此,整合於積體電路內部的晶片上解決方案,更加符合業界實際需求。
整合於積體電路內部的暫態偵測電路結合韌體或軟體設定的晶片上解決方案,已經被證明能夠有效提升微電子產品在系統層級靜電放電以及電性快速脈衝測試下的防護能力。本论文首先提出一個新的晶片上暫態偵測電路設計方案。此暫態偵測电路採用無電容設計,經由0.18-μm CMOS製程技術實現。通過相關模擬及實際量測,新提出的晶片上暫態偵測電路能夠成功偵測系統層級靜電放電以及電性快速脈衝所引起的電源擾動,並送出轉態之邏輯訊號供系統執行回復。當系統回復執行完畢,配合重置訊號,此偵測電路可被重置爲初始態,以實現下一次的暫態雜訊干擾的偵測。
其次,提出一個在0.18-μm CMOS製程技術下,所實現的具自我重置功能的暫態偵測電路。此電路結合電容電阻延遲效應,利用反饋迴路的設計,以實現暫態偵測電路的偵測及自我重置功能。此暫態偵測電路在系統層級靜電放電或電性快速脈衝發生時,可成功偵測並記錄由靜電放電引起的發生在電源線上的暫態干擾,並送出系統所需的回復指針。在系統回復執行完畢後,此暫態偵測電路無需重置訊號即可實現自我重置至初始狀態,以偵測下一次暫態雜訊干擾,從而避免因重置訊號被暫態雜訊干擾而造成的系統故障。
With the progress of CMOS semiconductor process, the increasingly complex integrated circuits (ICs) can be widely used in microelectronic products. In the variety of end users’ environments, the ICs are unable to guarantee its reliability, even that has passed Component-Level ESD test. Therefore, the protection of system-level ESD and EFT tests, which simulate ESD events in an end user’s environment, becomes a significant issue in the reliability design of CMOS ICs. Under the system-level electrical-transient disturbance tests, which specified in IEC 61000-4-2 and IEC 61000-4-4, the ESD-induced fast electrical transient can be randomly coupled to the power, ground and I/O pins to result in a hardware damage or system malfunction. In traditional solutions, extra discrete components are added on PCB to suppress the transient disturbance, such as TVS or board-level noise filter network. However, the board-level solution is not cost efficient to microelectronic products. Therefore, an on-chip solution is highly desired by industry.
It has been proven that an on-chip transient detection circuit with hardware/firmware co-design can effectively enhance the immunity of CMOS ICs against the system-level ESD and EFT tests. In the thesis, firstly, a new on-chip transient detection circuit has been proposed and fabricated in a 0.18-μm CMOS process. It has been confirmed that with this capacitor-less on-chip transient detection circuit, the occurrence of electrical transient coupled to power lines due to system-level ESD or EFT event can be successfully detected and memorized. The memorized state can be further used as firmware index to execute the system recovery procedure. When system recovery ends, the proposed transient detection circuit can be reset to initial state with reset signal for next electrical transient detection.
Secondly, a novel on-chip self-reset transient detection circuit has been proposed. This circuit has been designed and fabricated in a 0.18-μm CMOS process. With different feedback, this CR-based transient detection circuit can realize the detection and self-reset function. The system-level ESD and EFT test results have confirmed that the proposed on-chip self-reset detection circuit can successfully store the occurrence of electrical transient disturbance on power lines and release the stored state after a time constant automatically. In system application, the hardware/firmware co-designed with this self-reset transient detection circuit can avoid the system upset caused by the mistriggering of reset signal.