獨立成份分析法應用於腦血管數位減贅攝影之研究
The Study of Cerebral Digital Subtraction Angiography by Using Independent Component Analysis
摘要
目的
數位減贅攝影 (digital subtraction angiography, DSA),因其良好的空間與時間解析度,在診斷腦血管疾病 (cerebrovascular disease) 上,被視為臨床黃金標準。現今醫院使用的分析軟體中,仍須手動圈選感興趣範圍 (region of interest, ROI) ,取得影像訊號隨時間之變化 (time density curve, TDC),耗費時間。另外,此技術會受到病患檢查過程中些許移動影響,使影像減贅後形成移動假影 (motion artifact),因而影響影像品質。本研究對減贅前DSA影像序列進行對位 (registration),校正其移動假影。並利用獨立成份分析法 (independent component analysis, ICA),進行DSA影像訊號分析,以全自動的方式取得具有臨床意義之血流動力學 (hemodynamics) 資訊。
材料與方法
實驗分析50位頸動脈狹窄 (carotid stenosis) 病患,經由頸動脈血管成形與支架置放術 (carotid angioplasty and stenting) 治療前後DSA影像。利用尺度不變特徵轉換流方法 (scale-invariant feature transform flow),校正移動假影。經假影校正後,透過ICA將DSA影像,分成三種相位影像,即動脈相、微血管相和靜脈相。再將三相位影像,經大津二值化方法 (Otsu’s method),成為血管遮罩影像,以測量TDC曲線及其特性參數。方均根差 (root-mean square deviation) 被用來比較移動假影校正結果,以及自動萃取TDC與手動圈選TDC間的差異。而自動萃取TDC特性參數和手動圈選ROI的結果進行相關性分析,並利用學生t檢驗,分析治療前後的參數改變,藉此驗證其臨床意義。
結果
在移動假影校正方面,透過校正前後影像比較,除了少數案例,因病患移動過大,導致不理想之校正結果外,可以發現大部分假影皆被消除。而自動分析與手動圈選之相關性比較上,證明兩者在訊號相同參數間,具有良好之相關性存在,驗證了自動定量的可信度。最後,透過學生t檢驗,發現多項TDC參數,包括顯影劑到達時間 (bolus arrival time),濃度達最高值時間 (time to peak),下降斜率 (wash-out slope),半高全寬 (full width at half maximum),與曲線下面積 (area under the curve),治療前後比較皆具有顯著差異。此結果與先前發表,手動圈選定量結果,相當吻合。
結論
DSA影像分析中,TDC參數的定量研究,已經有許多不同研究,證實其臨床意義與價值。而這些定量技術的驗證和發展,最終都希望能夠實際應用於臨床工作流程中,輔助醫師診斷治療相關疾病。然而,目前相關定量研究中,皆須透過人工方式進行,對於應用在手術中並不方便。因此,自動影像分析方法的探討,為必要發展趨勢。本研究期望建立可靠穩定之自動分析技術,增進臨床工作效率,與提升診斷及治療品質。
數位減贅攝影 (digital subtraction angiography, DSA),因其良好的空間與時間解析度,在診斷腦血管疾病 (cerebrovascular disease) 上,被視為臨床黃金標準。現今醫院使用的分析軟體中,仍須手動圈選感興趣範圍 (region of interest, ROI) ,取得影像訊號隨時間之變化 (time density curve, TDC),耗費時間。另外,此技術會受到病患檢查過程中些許移動影響,使影像減贅後形成移動假影 (motion artifact),因而影響影像品質。本研究對減贅前DSA影像序列進行對位 (registration),校正其移動假影。並利用獨立成份分析法 (independent component analysis, ICA),進行DSA影像訊號分析,以全自動的方式取得具有臨床意義之血流動力學 (hemodynamics) 資訊。
材料與方法
實驗分析50位頸動脈狹窄 (carotid stenosis) 病患,經由頸動脈血管成形與支架置放術 (carotid angioplasty and stenting) 治療前後DSA影像。利用尺度不變特徵轉換流方法 (scale-invariant feature transform flow),校正移動假影。經假影校正後,透過ICA將DSA影像,分成三種相位影像,即動脈相、微血管相和靜脈相。再將三相位影像,經大津二值化方法 (Otsu’s method),成為血管遮罩影像,以測量TDC曲線及其特性參數。方均根差 (root-mean square deviation) 被用來比較移動假影校正結果,以及自動萃取TDC與手動圈選TDC間的差異。而自動萃取TDC特性參數和手動圈選ROI的結果進行相關性分析,並利用學生t檢驗,分析治療前後的參數改變,藉此驗證其臨床意義。
結果
在移動假影校正方面,透過校正前後影像比較,除了少數案例,因病患移動過大,導致不理想之校正結果外,可以發現大部分假影皆被消除。而自動分析與手動圈選之相關性比較上,證明兩者在訊號相同參數間,具有良好之相關性存在,驗證了自動定量的可信度。最後,透過學生t檢驗,發現多項TDC參數,包括顯影劑到達時間 (bolus arrival time),濃度達最高值時間 (time to peak),下降斜率 (wash-out slope),半高全寬 (full width at half maximum),與曲線下面積 (area under the curve),治療前後比較皆具有顯著差異。此結果與先前發表,手動圈選定量結果,相當吻合。
結論
DSA影像分析中,TDC參數的定量研究,已經有許多不同研究,證實其臨床意義與價值。而這些定量技術的驗證和發展,最終都希望能夠實際應用於臨床工作流程中,輔助醫師診斷治療相關疾病。然而,目前相關定量研究中,皆須透過人工方式進行,對於應用在手術中並不方便。因此,自動影像分析方法的探討,為必要發展趨勢。本研究期望建立可靠穩定之自動分析技術,增進臨床工作效率,與提升診斷及治療品質。
Purpose: In clinical practice, DSA is always the gold standard for diagnosis of cerebrovascular disease. However, this technology often suffers from the motion artifact caused by the patients’ unpredictable motion during scan time. The clinical applications in quantitative DSA still need to be achieved manually. This research presents an automatic technique to analyze digital subtraction angiography (DSA) images. A registration process is applied to eliminate the motion artifact. The DSA sequences are analyzed automatically by using independent component analysis.
Material and Methods: DSA images of fifty patients with carotid stenosis who underwent carotid angioplasty and stent placement were collected for retrospective analysis. The scale-invariant feature transform flow algorithm was utilized as the motion correction approach. Three independent components that were arterial, capillary and venous phases were obtained through independent component analysis. Time density curves (TDC) were extracted from vessel masks of those phases generated by using the Otsu’s threshold method. Root-mean-square deviation between the DSA images before and after motion correction was used to test the efficacy of the result. Root-mean-square deviation and correlation coefficients between TDC gathered from the hand-operated selection of region of interests and the automatic ICA scheme were investigated to verify the credibility of the ICA method. Finally, Student’s paired t-test was applied to further study meaningful interpretation between pre- and post-treatment of TDC parameters which were derived from ICA method.
Results: In motion correction, though a few cases displayed not expected outcomes, the scale-invariant feature transform flow algorithm worked well in most cases. The result showed good correlation between same TDC parameters from manual selection and automatic ICA scheme. Finally, there were significant differences before and after treatments in most parameters including bolus arrival time, time to peak, washout slope, full width at half maximum, and area under the curve. This result demonstrated almost the same as the previous manual quantitative study.
Conclusions: There are lots of research regarding quantitation of TDC parameters intended to be implemented in clinical workflows to support clinicians in diagnosis and treatment planning. Nonetheless, related approaches still need to be done manually, which is inconvenient during operation. We developed a fully automatic quantitative system for clinical usage.
Material and Methods: DSA images of fifty patients with carotid stenosis who underwent carotid angioplasty and stent placement were collected for retrospective analysis. The scale-invariant feature transform flow algorithm was utilized as the motion correction approach. Three independent components that were arterial, capillary and venous phases were obtained through independent component analysis. Time density curves (TDC) were extracted from vessel masks of those phases generated by using the Otsu’s threshold method. Root-mean-square deviation between the DSA images before and after motion correction was used to test the efficacy of the result. Root-mean-square deviation and correlation coefficients between TDC gathered from the hand-operated selection of region of interests and the automatic ICA scheme were investigated to verify the credibility of the ICA method. Finally, Student’s paired t-test was applied to further study meaningful interpretation between pre- and post-treatment of TDC parameters which were derived from ICA method.
Results: In motion correction, though a few cases displayed not expected outcomes, the scale-invariant feature transform flow algorithm worked well in most cases. The result showed good correlation between same TDC parameters from manual selection and automatic ICA scheme. Finally, there were significant differences before and after treatments in most parameters including bolus arrival time, time to peak, washout slope, full width at half maximum, and area under the curve. This result demonstrated almost the same as the previous manual quantitative study.
Conclusions: There are lots of research regarding quantitation of TDC parameters intended to be implemented in clinical workflows to support clinicians in diagnosis and treatment planning. Nonetheless, related approaches still need to be done manually, which is inconvenient during operation. We developed a fully automatic quantitative system for clinical usage.