以單陣元超音波探頭輔助之雙模小動物腫瘤螢光斷層影像系統
Single-element Ultrasound Transducer Guided Fluorescence Diffusion Optical Tomography System for Small Animals Tumor Imaging
摘要
螢光擴散光學斷層(FDOT)為一非侵入式之小動物功能性影像,其以擴散光學斷層(DOT)為基礎,利用光子對不同物質擁有的吸收與散射係數特性,重建出二維切面的組織資訊;而比起傳統擴散光學斷層影像,螢光可提供正常組織與病變組織之間更好的對比度。
本研究提供一結合超音波訊號與螢光影像擷取之雙模平面式小動物造影平台。利用創新性的穿孔混合式單陣元超音波探頭(single-element disk transducer)對待測物進行光學與超聲波同軸掃描,同時得到FDOT重建所需之功能性影像(functional information)及結構性影像(prior information);上方以電子增益電荷耦合元件(Electron Multiplying Charge Coupled Device, EMCCD)搭配激發光(660nm)以及螢光(705nm)波段之雷射與濾波片,收取所需之光學訊號。帶入上述兩者資訊,可利用螢光擴散光學重建演算法工具(Near Infrared Fluorescence and Spectral Tomography, Nirfast) 進行運算,得到物體斷面影像。研究結果經仿體、肉塊及老鼠實驗驗證,由FDOT影像與切面資訊(line profile)可得知,加入超音波之prior information重建影像邊緣較銳利,軟組織及腫瘤輪廓也能同時得到良好結果。
本研究提供一結合超音波訊號與螢光影像擷取之雙模平面式小動物造影平台。利用創新性的穿孔混合式單陣元超音波探頭(single-element disk transducer)對待測物進行光學與超聲波同軸掃描,同時得到FDOT重建所需之功能性影像(functional information)及結構性影像(prior information);上方以電子增益電荷耦合元件(Electron Multiplying Charge Coupled Device, EMCCD)搭配激發光(660nm)以及螢光(705nm)波段之雷射與濾波片,收取所需之光學訊號。帶入上述兩者資訊,可利用螢光擴散光學重建演算法工具(Near Infrared Fluorescence and Spectral Tomography, Nirfast) 進行運算,得到物體斷面影像。研究結果經仿體、肉塊及老鼠實驗驗證,由FDOT影像與切面資訊(line profile)可得知,加入超音波之prior information重建影像邊緣較銳利,軟組織及腫瘤輪廓也能同時得到良好結果。
Fluorescence diffusion optical tomography(FDOT) is a non-invasive functional image of small animals. It based on diffusion optical tomography(DOT) algorithm and combined with fluorescent molecular characteristics in different tissues to reconstruct a 2D optical tomography. Compared with the traditional diffusion optical tomography, fluorescence provides better contrast between normal and diseased parts.
Our research developed a dual modality planar small animal imaging system including ultrasound signals and fluorescent images. An innovative hybrid single-element disk transducer with center perforation is used to do the ultrasound and optic coaxial scan, which can obtain both functional and structural information. On the top, there is an electron multiplying charge coupled device(EMCCD) to acquire optical signal of excitation and emission wavelength by specific filters(660nm&705nm). With the information above, we can reconstruct FDOT images by Nirfast.
Results verified by phantom, meat and mice. From line profile and tomographic images, they prove that ultrasound prior information improve the image qualities. It can not only sharpen the edges, but also reveals good resolution on soft tissues and tumor margin.
Our research developed a dual modality planar small animal imaging system including ultrasound signals and fluorescent images. An innovative hybrid single-element disk transducer with center perforation is used to do the ultrasound and optic coaxial scan, which can obtain both functional and structural information. On the top, there is an electron multiplying charge coupled device(EMCCD) to acquire optical signal of excitation and emission wavelength by specific filters(660nm&705nm). With the information above, we can reconstruct FDOT images by Nirfast.
Results verified by phantom, meat and mice. From line profile and tomographic images, they prove that ultrasound prior information improve the image qualities. It can not only sharpen the edges, but also reveals good resolution on soft tissues and tumor margin.