摘要

震盪式抽水試驗(oscillatory pumping test)為新近發展的抽水試驗,其抽水率隨時間變化,可表示為正弦函數,近年來常應用於水力斷層掃瞄。過去相關的研究涉及兩個假設:(1) 忽略地下水位的初始條件,水位隨時間的變化視為簡諧震盪(simple harmonic motion)。(2) 抽水井視為一個線沉(line sink),忽略井半徑與井蓄水(wellbore storage)效應。這兩個假設導致於試驗井附近的水位有顯著的誤差。有鑒於此,本研究發展一個新的數學模式,考慮地下水位的初始條件和井蓄水效應,來描述自由含水層中因震盪抽水引起的地下水位變動,應用Laplace Transform及finite integral transform求得模式的水力水頭(hydraulic head)解析解,分析水力參數的敏感度。研究結果顯示,縱使井的內徑極小,忽略井蓄水效應仍導致高估地下水位震盪的振幅。初始條件的影響隨時間減少,在一段抽水時間後,地下水位變化可視為簡諧震盪,新的解析解能量化該抽水時間。此外,我們提供一回歸方程式,定義影響半徑和震盪式抽水頻率的關係,能當作設置觀測井的依據。解析解的預測結果,與美國愛達荷州博伊西市水文地質研究區(Boise hydrogeophysical research site)的觀測水位,有良好的一致性。
An alternative method to the constant-head or constant-rate pumping test for aquifer characterization is oscillatory pumping for which the change of pumping rate can be a typical sinusoidal function of time. Existing models accounting for the test mostly neglect the wellbore storage effect and the effect of the initial condition of the aquifer flow system. This study develops a new model for describing the hydraulic head variation due to oscillatory pumping in an unconfined aquifer with considering the effects of the wellbore storage and initial condition. The model contains a typical flow equation in the cylindrical coordinate system with an initial condition regarding static groundwater level, inner boundary condition specified at the rim of the testing well for incorporating the wellbore storage effect, and linearized free surface equation representing the water table movement. The analytical solution of the model is derived by the methods of Laplace transform and finite integral transform. The solution exhibits that the head fluctuation tends to SHM after a certain period of testing time. The elapsed time to reach simple harmonic motion (SHM) is quantified. The validity of the assumption for an infinitesimal well radius without wellbore storage effect is investigated. The relation between the radius of influence and the frequency of pumping rate is also quantitatively provided. The sensitivity analysis is carried out for exploring the head response to the change in each of the hydraulic parameters. Head fluctuation predicted by the present solution shows good agreement with field data observed at the Boise hydrogeophysical research site in southwestern Idaho.

所屬典藏

環境工程研究所
顯示完整詮釋資料 統計資料

引用此條目

Tsai, Y.-H. (2018). Analysis of Groundwater Response to Oscillatory Pumping in Unconfined Aquifers: Consider the Effects of Initial Condition and Wellbore Storage. https://thesis.lib.nycu.edu.tw/handle/20.500.14371/67969

BibTeX RIS

引用文字依 APA 第 7 版格式自動產生,使用前請再核對。

分享

永久網址:https://thesis.lib.nycu.edu.tw/handle/20.500.14371/67969