血漿於體外超音波照射下凝血時間之影響

Effect of in vitro Plasma Clotting Time by Ultrasound

檔案

全文未公開。

日期

2018

類型

語言

中文

摘要

目前已知超音波與組織之間交互作用下可以誘導的生物效應極為廣泛,且誘發之各種治療模式效果因而被應用於生物醫學各個不同治療領域上。然而治療超音波領域中,最重要又極為複雜的一環即是聲學止血的應用,雖然目前已有許多研究指出超音波能誘導止血的效果,不過由於其牽涉止血與凝血級聯反應複雜之過程,以及超音波與血液及血管交互作用所涉及的凝血之物理細節尚未清楚瞭解,故本研究欲探討超音波的生物效應對凝血因子會產生何種生理影響,是否會被超音波刺激活化進而引發一連串之凝血反應,或是受其影響而抑制凝血途徑。
本研究以新鮮冷凍血漿 (FFP) 為測試凝血的樣本,並選用部份活化凝血活酶時間 (APTT) 作為測試凝血因子功能之試驗,以探究治療超音波照射下是否會對血液凝血時間造成變化及影響,此外,加上對於各種聲學參數與血液間的相對關係並不瞭解,因此實驗選用不同的超音波參數,如頻率 (1 MHz、3.2 MHz )、工作週期 (Continuous、50% duty cycle )、強度 (0.5 W/cm²、1 W/cm²、2 W/cm²) 與三種照射時間 (30 sec.、1 min.、2 min.),一共有36組參數的組合,觀察每一組聲學參數下之 APTT 值有無顯著不同。
實驗結果發現 FFP 於 30 秒與 1 分鐘照射下,大部分聲學參數組呈現顯著的凝血時間縮短,因此推斷實驗所使用的聲學參數組會對內源性凝血途徑造成加速凝血反應,而 2 分鐘照射下則沒有顯著的變化,造成此結果的機制則需更進一步實驗探討。
It was known that the interaction of ultrasound with tissue can result in the bioeffects is extremely wide that enable to be applied to the treatment of a wide range of clinical fields in biomedicine. However, acoustic hemostasis is one of the extremely complex applications in the ultrasound therapy. Although many studies have demonstrated that ultrasound can induce hemostasis, it involves complex processes of coagulation cascade and mechanisms of ultrasound-blood interaction are not clearly understood. Therefore, the purpose of this study was to investigate the physiological effect of coagulation factors induced by ultrasound exposure and observe whether coagulation factors would be activated to trigger a series of coagulation reactions or be inhibited the coagulation pathway by ultrasound stimulation.
In this study, we used fresh frozen plasma (FFP) for coagulation test sample and exposed to ultrasound, immediately thereafter, the activated partial thromboplastin time (APTT) was performed in order to explore the effect of ultrasound on clotting time. In addition, due to the lack of understanding of the relative relationship between various acoustic parameters and blood, we selected different combinations of ultrasound parameters such as frequency (1 MHz, 3.2 MHz), duty cycle (Continuous, 50% duty cycle), intensity (0.5 W/cm², 1 W/cm², 2 W/cm²) and three exposure times (30 sec., 1 min., 2 min.), a total of 36 acoustic parameters were to determine the APTT value under each acoustic parameters.
The experimental results showed that APTT under most of the acoustic parameters significantly decreased at 30 sec. and 1 min. exposure, therefore, it was concluded that the acoustic parameters used in the experiment might induce activation of intrinsic coagulation pathway to accelerate coagulation reactions. However, there was no significant change at 2 min. ultrasound exposure, and the mechanism for this result needs further investigation.