木質顆粒固定床燃燒爐之流場模擬
Numerical Investigation of Combustion Flow Fields Inside a Wood Pellet Fixed-bed Furnace
摘要
近年由於環保意高漲,工業減碳漸漸被人們重視。生質燃料因具有碳中和之特性,為有效降低二氧化碳排放量兼具環境友善的潔淨能源。本研究將對中鋼公司之爐石熱風供應系統之其中一個木質顆粒固定床燃燒爐進行燃燒流場的研究。此燃燒爐包含一次風、送料風、二次風、三次風等風口。本研究採用商業套裝軟體ANSYS/FLUENT,首先以UDFs建立暫態的固定床模組,並從此模組中獲得裂解氣體之詳細資訊,以此進行穩態的燃燒場以及不同總空燃比以及爐內外空燃比的參數的分析。研究結果顯示,從固定床模組所計算之裂解氣體之熱值與實驗所測得之熱值誤差值為4.4%。參數分析結果顯示,總空燃比1.22時火焰長度為2.65m,爐內空燃比1.35時CO排放率最為0.0133(CO-kg/wood-kg)。實驗數據比對的部分,在爐內缺氧燃燒之情形下,模擬所得之爐內溫度較實驗值高,其原因可能為可燃氣體之反應率在缺氧情況下可能被高估。
In this research it is focused on employing the numerical simulation tool to wood pellet Fixed-bed Furnace. The ANSYS / FLUENT software is adopted to investigate the physical adsorption and flow field details. First, establish a transient fixed bed module with UDFs, and obtain detailed information on the volatile from fixed bed, then analyze the steady state combustion field and the parameter changes. The results show that the calorific value of the pyrolysis gas calculated from the fixed bed module and the experimentally measured calorific value are 4.4%. The parameter analysis results show that the flame length is 2.65m when the total air-fuel ratio is 1.22, and the CO emission rate is 0.0133 (CO-kg/wood-kg) when the air-fuel ratio is 1.35. However, the performance of zeolite is much lower than the expected value.