第一期臨床試驗中,傳統3+3設計及修正毒性機率區間設計對最大耐受劑量的探討

The 3 +3 Design And Modified Toxicity Probability Interval Designs For The Maximum Tolerated Dose (MTD) In Phase I Clinical Trial

檔案

全文未公開。

日期

2018

類型

語言

中文

摘要

  在新藥的研發中,第一期臨床試驗的研究目的為訂定新藥之最大耐受劑量。廣為大家使用的方法是3+3設計,因為易懂且執行上相當簡單,可是,有找不到最準確的最大耐受劑量的可能性,通常是低估。
  而Yuan Ji等人在2010年發表modified toxicity probability interval method (mPTI,本研究翻譯為修正毒性機率區間設計),將3+3設計結合貝氏定理,能更精準地找到最大耐受劑量,在可承受的副作用下,找出藥物最佳的治療效果。但考量研究成本上,此方法有兩個問題,第一個是當起始劑量非毒性過強的情況下,收滿試驗人數才決定最大耐受劑量,相當耗費時間與金錢。另一個是當遇到毒性過強的初始劑量,要提前中止試驗,也需觀察多位受試者出現劑量限制毒性,才會下此判斷,但這已讓多位受試者承受過大的副作用影響。
  因此本研究,我們對修正毒性機率區間設計提出修正,保留3+3設計簡單易操作,在初始劑量過毒的情況下及時中止試驗的優點,以及修正毒性機率區間設計,找到較為準確的最大耐受劑量的優點。
  從模擬研究的結果中,可看出本研究的改進方法是在準確率與所需人數之間作取捨,如果要更高的準確率,則需更多的受試者參加試驗來判斷;而如果經費有限,希望降低所需人數或者縮短試驗時間,則犧牲掉些許的準確率。不過,當初始劑量過毒的情況下,能及時地中止試驗,降低可能造成受試者的傷害。
The widely used method is 3 + 3 design, because it is easy to understand and the implementation is quite simple. However, there is no possibility of finding the accurate maximum tolerated dose, since it is usually underestimated.
Yuan Ji et al. in 2010 published the modified toxicity probability interval design, mPTI, which combined with the 3+3 design and Bayes theorem, can more accurately find the maximum tolerated dose, under the premise of tolerable side effect shown by the subjects, the best therapeutic drug effect can be found.
However, considering the cost of the research, there are two major problems to this method. Firstly, in order to determine the maximum dose, the research involve requirements of collecting numbers of subjects, which is quite time-consuming and costly. Secondly, when the initial dose is too high, early determination of clinical trials is to be established. Randomized control trials stopped early for benefit will, on average, overestimate treatment effects, moreover, it causes harm to the trail participants.
We propose amendments to the modified toxicity probability interval method, which retains the advantages of 3+3 design had simple operation, and the discontinuation of the trial in the case of initial dose overdosed, and the advantages of the modified toxicity probability interval method had finding more correct the maximum tolerated dose.
From the results of the simulation study, it can be seen that the improvement of this study is to choose between the accuracy rate and the number of subjects, if you want a higher accuracy rate, you have to collect more subjects; If the funds are limited, want to reduce the number of subjects or shorten the time of trial, then sacrifice a little accuracy. Since the initial dose is overdosed level, the trial should be discontinued to reduce the harm that may cause to the subjects.
The recommendations from the simulation results were provided to the investigator, and after considering the accuracy of the maximum tolerated dose and the cost of the trail to select the optimal setting to find appropriate the most maximum tolerated dose. 

所屬典藏

公共衛生研究所
顯示完整詮釋資料 統計資料

引用此條目

温芳羽 (2018). 第一期臨床試驗中,傳統3+3設計及修正毒性機率區間設計對最大耐受劑量的探討. https://thesis.lib.nycu.edu.tw/handle/20.500.14371/69867