神經內分泌腫瘤Ki67增殖指數自動分析程式開發
The Development of an Automated Analysis Program for Ki67 Proliferative Index of Neuroendocrine Tumors
摘要
數位影像分析方法在近年多有被提出以輔助神經內分泌腫瘤 Ki67 增殖指數的計算,期能解決傳統人為評估方法高主觀性以及對準確度與工作效率的兩難。然神經內分泌腫瘤病理影像中非腫瘤組織與細胞對數位影像分析的干擾甚深,演算法如若不能有效區別腫瘤與非腫瘤組織易高估 Ki67 增殖指數。本研究結合 synaptophysin-Ki67 雙重染色及數位影像分析方法,對 synaptophysin 抗原染色標定腫瘤組織以提供影像分析有力的特徵,基於影像處理與機器學習等技術開發分析程式自動檢測 Ki67 陽性與陰性腫瘤細胞以計算 Ki67 增殖指數,並設計實驗與傳統人為評估方法相比較。
以醫師藉電腦輔助的評估結果為黃金標準,程式分析與之相關係數為 0.99 (95% CI: 0.99-1.00),高於以目測法評估 Ki67 單染色 (0.60, 95% CI: 0.45-0.73) 及 synaptophysin-Ki67 雙重染色 (0.81, 95% CI: 0.72-0.87) 組織切片,及以目視計數法評估 synaptophysin-Ki67 雙重染色組織切片影像 (0.81, 95% CI: 0.72-0.87) 的結果。程式分析對 Ki67 陽性及陰性腫瘤細胞的檢測靈敏度分別為 0.9819 及 0.9552,僅 0.11% 的非腫瘤組織被誤判為腫瘤細胞。
以醫師藉電腦輔助的評估結果為黃金標準,程式分析與之相關係數為 0.99 (95% CI: 0.99-1.00),高於以目測法評估 Ki67 單染色 (0.60, 95% CI: 0.45-0.73) 及 synaptophysin-Ki67 雙重染色 (0.81, 95% CI: 0.72-0.87) 組織切片,及以目視計數法評估 synaptophysin-Ki67 雙重染色組織切片影像 (0.81, 95% CI: 0.72-0.87) 的結果。程式分析對 Ki67 陽性及陰性腫瘤細胞的檢測靈敏度分別為 0.9819 及 0.9552,僅 0.11% 的非腫瘤組織被誤判為腫瘤細胞。
Digital image analysis is repeatedly proposed for the assessment of Ki67 proliferative index of neuroendocrine tumors recently. It’s expected to overcome the dilemma of accuracy or efficiency encountered in several conventional methods. Unfortunately, distinguishing tumor from non-tumor is regarded as an obstacle to digital image analysis, which usually makes it over-estimation on Ki67 proliferative index. In this study, we described an automated analysis program in analyzing digital images of synaptophysin-Ki67 double stained slides. Staining synaptophysin highlights where tumor tissues are and makes it a strong feature for automated recognition. The automated analysis program we proposed is developed based on techniques of digital image processing and machine learning, and aimed to detect Ki67-positive and -negative tumor cells.
Taking the Ki67 scores made by the computer-aided assessment (CAA) with an experienced pathologist as the gold standard, the outcomes made by our program showed high agreement (ICC: 0.99, 95% CI: 0.99-1.00) with CAA. And it’s significantly higher than those assessed by eyeball estimation (EE) of Ki67-only stained slides (ICC: 0.60, 95% CI: 0.45-0.73), by EE of synaptophysin-Ki67 double stained slides (ICC: 0.81, 95% CI: 0.72-0.87), and by eye-counting of pre-captured synaptophysin-Ki67 double stained slides images (ICC: 0.81, 95% CI: 0.72-0.87). As for the accuracy of single-cell detection, the sensitivities of Ki67-positive and -negative tumor cells are 0.9819 and 0.9552, while only 0.11% of false alarm toward non-tumor tissue.
Taking the Ki67 scores made by the computer-aided assessment (CAA) with an experienced pathologist as the gold standard, the outcomes made by our program showed high agreement (ICC: 0.99, 95% CI: 0.99-1.00) with CAA. And it’s significantly higher than those assessed by eyeball estimation (EE) of Ki67-only stained slides (ICC: 0.60, 95% CI: 0.45-0.73), by EE of synaptophysin-Ki67 double stained slides (ICC: 0.81, 95% CI: 0.72-0.87), and by eye-counting of pre-captured synaptophysin-Ki67 double stained slides images (ICC: 0.81, 95% CI: 0.72-0.87). As for the accuracy of single-cell detection, the sensitivities of Ki67-positive and -negative tumor cells are 0.9819 and 0.9552, while only 0.11% of false alarm toward non-tumor tissue.