以慣性感測器開發一以日常生活動作基礎之個人化跌倒感測參數

Developing personalized fall detecting parameters based on activities of daily living using inertial sensors

檔案

全文未公開。

日期

2019

類型

語言

中文

摘要

跌倒為日常生活中常見之意外,特別好發於高齡族群,如何降低跌倒造成的傷害是重要的課題,一般常見慣性感測器(例如:加速規、陀螺儀)有著能夠及時反應、沒有空間限制等優點,可用於穿戴式動作偵測,而過去以慣性感測器做為跌倒偵測的研究中,多以年輕族群進行實驗,而非高齡族群。跌倒實驗主要以主動傾倒,而少有「真實」跌倒。跌倒演算法閾值多以群體固定閾值為設定,本研究受限於高齡者容易受傷,因此招募年輕族群穿著自製高齡模擬裝備,以負重、限制動作等方式降低其動作反應,以個人日常生活動作表現做為個人跌倒判斷閾值的設定,並且進行不預期跌倒實驗與日常生活動作實驗。
本研究以三軸加速規與陀螺儀的慣性感測器,招募10位健康的成年受測者(1.70±0.11m;66.8±16.4kg;24.6±2.2yrs)參與本實驗,實驗於居家空間進行日常生活動作(activities of daily living, ADLs),每位受測者著高齡模擬裝備進行十組日常生活動作實驗,並且隨機設置非預期性絆倒與滑倒。以固定閾值與個人化閾值兩種閾值方式進行分析,並以MyRio計算演算法計算所需時間,最合適之跌倒閾值選擇以領先時間(lead time)權重、靈敏度(sensitivity)、特異性(specificity)等參數進行,結果顯示,以個人數據之走路最小加速度平均值之0.85倍與彎腰最大角速度平均值之0.85倍為閾值置於胸前最為合適,其靈敏度為100%、特異性為94.8%、平均領先時間(mean lead time)為574毫秒,最小領先(minimum lead time)時間則為300毫秒。
實際應用該閾值與演算法在即時跌倒防護上的評估,以過去文獻與市售商品進行回顧傳輸時間、運算時間、啟動時間與防護時間進行最小領先時間評估,最少領先時間需求為230毫秒,本研究完成以走路加速度與彎腰角速度兩種動作進行個人化跌倒感測閾值設定,在結果顯示靈敏度為100%、特異性在考慮實際可能使用情形將站立到躺下的動作排除後上升至97.5%,最小領先時間為300毫秒,滿足即時跌倒防護所需要之領先時間230毫秒,確立可以使用在即時跌倒防護。
ABSTRACT

Falling is a common accident, especially in the elderly. How to reduce the damage caused by falls is an important issue. Inertial sensors (such as accelerometers and gyroscopes), having the advantages of real-time detection and small-sized, and usually used on motion detecting. Past researches that detect falls using inertial sensors usually recruited young subjects instead of elders as their experimental subjects. In addition, most of their fall experiments were asked subjects to perform falling instead of real fall. Therefore, in this study we recruited young subjects and reduced their movement response by wearing aging-suit because it’s too risky to recruit elder subject. We set the threshold based on of individual activities of daily living(ADLs) and do the unexpected fall experiments and ADLs experiment.
In this study, we used inertial sensors with tri-axial accelerometer and tri-axial gyroscope. We recruited 10 healthy young subjects (1.70±0.11m; 66.8±16.4kg; 24.6±2.2yrs). Each subject was asked to do activities of daily living for 10 trials in a home-like environment. We set obstacles and slippery surface randomly to induce unexpected trips and slips during the experiments. We set up personal thresholds and group thresholds to analyze data, and recorded the calculation time of the algorithm using MyRio The proper thresholds were calculated by weighting of lead time, sensitivity and specificity
The results show that the proper personal thresholds of acceleration is 0.85 time of average of minimum acceleration of walk data, thresholds of angular velocity is 0.85 time of average of maximum angular velocity of bend data on chest. The analysis results of the thresholds show that sensitivity was 100%, specificity was 94.8%, mean lead time was 574ms, minimum lead time was 300ms and calculation time was 1ms.
Considering the application scenarios, we excluded the movement of stand to lying, then specificity will rise to 97.5%. To evaluate the possibility of the algorithm using on instant fall protection, we review the commercial product and past studies to set up the minimum requirement of lead time. The minimum requirement of lead time was 230ms combined with calculation time, activation time and inflation time.
In this study, we develop personal fall detection threshold setting method base on individual actions of walking and bending, and the sensitivity and specificity of the results are higher than group thresholds. The minimum lead time is 300 milliseconds which is sufficient the requirement of lead time of instant fall protection.