選擇性修飾奈米金屬鈀於矽奈米帶之氫氣感測研究
A Study of Selective Decoration of Pd Nanoparticles on Silicon Nanobelt Devices as Hydrogen Gas Sensors
摘要
本研究利用焦耳熱以及電漿輔助原子沉積技術(Plasma-Enhanced Atomic Layer Deposition, PEALD)選擇性沉積鈀奈米顆粒於雙接面(n+/n-/n+)多晶矽奈米帶(Polysilicon Nanobelt, PNB)元件的n-區域上並做為氫氣感測器使用。研究也成功利用以定功率的方式,將元件溫度控制在電漿輔助原子沉積成長鈀(Pd)的溫度範圍內,再藉由控制電漿輔助原子層沉積系統之循環(cycle)次數,來調整奈米帶上鈀奈米顆粒的大小。研究結果發現300 沉積循環成長的鈀奈米顆粒之表面粗糙
度適當(約1.77 奈米),在室溫對氫氣之靈敏度(1.2%)也最高。由此推測300 沉積循環成長的鈀奈米顆粒在n-區域上擁有最大之表面積分佈。另外,研究也藉由對奈米帶施加電壓,使奈米帶元件工作在自熱(Self-heating)狀態;提升工作溫度使300 沉積循環成長的鈀奈米顆粒擁有更大的氫氣解離能力,提生感測效率。研究發現當元件施加10 V(358 K)時,擁有最大之靈敏度(2.5%),且能偵測氫氣的極限可達100 ppm。研究最後利用氧電漿和氫電漿清理鈀奈米顆粒表面的碳汙染,使受到環境汙染之元件靈敏度從1.9%回到2.3%。
度適當(約1.77 奈米),在室溫對氫氣之靈敏度(1.2%)也最高。由此推測300 沉積循環成長的鈀奈米顆粒在n-區域上擁有最大之表面積分佈。另外,研究也藉由對奈米帶施加電壓,使奈米帶元件工作在自熱(Self-heating)狀態;提升工作溫度使300 沉積循環成長的鈀奈米顆粒擁有更大的氫氣解離能力,提生感測效率。研究發現當元件施加10 V(358 K)時,擁有最大之靈敏度(2.5%),且能偵測氫氣的極限可達100 ppm。研究最後利用氧電漿和氫電漿清理鈀奈米顆粒表面的碳汙染,使受到環境汙染之元件靈敏度從1.9%回到2.3%。
This study employed localized Joule heating and Plasma-Enhanced Atomic Layer Deposition (PEALD) to deposit palladium nanoparticles selectively on the n- region
of a double-junction (n+/n-/n+) polysilicon nanobelt (PNB) device. The selective Pd-decorated nanodevices were then characterized as hydrogen sensors. To control the
device surface temperature within Pd depositon window during PEALD process, a constant power technique was introduced. The particle size of Pd nanoparticle was
control by adjusting the deposition cycle number of the plasma-assisted atomic layer deposition. It is found that the surface roughness of the 300-cycle deposited Pd was
around 1.77 nm and exhibited a sensitivity of 1.2% at room temperature. We suspected that the 300-cycle deposited Pd possess an adequate particle size and a largest surface coverage on n- region. In addition, device was functioned under self-heating during H2 sensing by applying a voltage 10 V (358 K) on the nanobelt device. Device with 300-cycle deposited Pd presented a maximum sensitivity (2.5%), and this device can detect 100 ppm of H2.Finally,carbonaceous device via environmental contamination was cleaned by a combination of oxygen plasma and hydrogen plasma treatment. A return of sensitivity from 1.9% to 2.3% was observed after the plasma treatments.
of a double-junction (n+/n-/n+) polysilicon nanobelt (PNB) device. The selective Pd-decorated nanodevices were then characterized as hydrogen sensors. To control the
device surface temperature within Pd depositon window during PEALD process, a constant power technique was introduced. The particle size of Pd nanoparticle was
control by adjusting the deposition cycle number of the plasma-assisted atomic layer deposition. It is found that the surface roughness of the 300-cycle deposited Pd was
around 1.77 nm and exhibited a sensitivity of 1.2% at room temperature. We suspected that the 300-cycle deposited Pd possess an adequate particle size and a largest surface coverage on n- region. In addition, device was functioned under self-heating during H2 sensing by applying a voltage 10 V (358 K) on the nanobelt device. Device with 300-cycle deposited Pd presented a maximum sensitivity (2.5%), and this device can detect 100 ppm of H2.Finally,carbonaceous device via environmental contamination was cleaned by a combination of oxygen plasma and hydrogen plasma treatment. A return of sensitivity from 1.9% to 2.3% was observed after the plasma treatments.