LCD背光膜組製程之脫脂廢水處理碳足跡研究
Carbon Footprint Study of Liquid Crystal Display Backlight Module by Degreasing Wastewater Treatment
摘要
隨著氣候變遷、地球暖化危機議題發酵,溫室氣體成為國際間炙手可熱的議題,許多科學研究報告顯示出,大氣中的二氧化碳濃度正逐漸上升當中,節能減碳之議題已是不可逃避;近年來各國相繼提出碳排放之計算,藉由碳排放的計算,分析出排放量最大的產業別以進行減少排放作業,期許可獲得最大效益。
本研究藉由『產品與服務碳足跡(Carbon Footprint)計算指引』分析,將個案公司脫脂廢水處理所產生之總碳排放量,依能資源、化學品及消耗品等單元區分,尋找碳排放量最大之單元並著手改善。其中化學品單元為最大排放,再以靈敏度分析實驗探討,分別模擬降低化學品碳排放係數或模擬降低化學品使用量,總排放量是否可降低且降低多少。由模擬假設降低化學品碳排放係數或降低化學品使用量均可達到總碳排放量降低之成效。
在本研究中藉由選用低化學品碳排放係數之化學品,總碳排放由原先的
1.25 kgCO2e/m3下降為1.16 kgCO2e/m3,總碳排放量約減少7.2%。但更換低碳排放係數之化學品造成運作成本增加,業界基於成本考量下此方法暫緩推行。而藉由加藥分析得知pH sensor擺放點位置會影響化學品重複添加追藥之情形。著手改善pH sensor擺放點後,化學品使用量下降且總碳排放量由原先的1.25 kgCO2e/m3下降為1.15 kgCO2e/m3,總碳排放量約減少10%。除此費用也減少3,428元/年。此方法可同時達到減少碳排放量與費用降低之雙效益。
本研究藉由『產品與服務碳足跡(Carbon Footprint)計算指引』分析,將個案公司脫脂廢水處理所產生之總碳排放量,依能資源、化學品及消耗品等單元區分,尋找碳排放量最大之單元並著手改善。其中化學品單元為最大排放,再以靈敏度分析實驗探討,分別模擬降低化學品碳排放係數或模擬降低化學品使用量,總排放量是否可降低且降低多少。由模擬假設降低化學品碳排放係數或降低化學品使用量均可達到總碳排放量降低之成效。
在本研究中藉由選用低化學品碳排放係數之化學品,總碳排放由原先的
1.25 kgCO2e/m3下降為1.16 kgCO2e/m3,總碳排放量約減少7.2%。但更換低碳排放係數之化學品造成運作成本增加,業界基於成本考量下此方法暫緩推行。而藉由加藥分析得知pH sensor擺放點位置會影響化學品重複添加追藥之情形。著手改善pH sensor擺放點後,化學品使用量下降且總碳排放量由原先的1.25 kgCO2e/m3下降為1.15 kgCO2e/m3,總碳排放量約減少10%。除此費用也減少3,428元/年。此方法可同時達到減少碳排放量與費用降低之雙效益。
With the crisis issues of climate change and global warming, greenhouse gases become an international issues. More and more scientific researches show that carbon dioxide concentration in the atmosphere is increasing year by year. Thus of reducing carbon dioxide is currently a global urgent issue.
In recent years, many countries have proposed ways to calculate the quantity of carbon emissions.
From the results of the calculation of carbon emissions, it can be pointed out which industries have the largest emissions to carbon dioxide production, and the actions can be then taken to get the maximum effectiveness of carbon emission reduction.
In this research, “Carbon Footprint Computation Guidelines” is used for the case study. The study of total carbon emissions from the degreasing wastewater treatment of the case company was based on energy resources, chemicals and consumables. The purpose is trying to find the chemical unit with the highest carbon emissions and to reduce its emissions. The results show that the chemical unit has the largest emission. Using sensitivity analysis for experiments simulations of reducing the carbon emission coefficient of chemicals and the use of chemicals separately, are carried out to determine whether the total emissions can be reduced.
From the simulations, chemicals of low carbon emission factors were chosen. Total carbon emissions decreased about 7.2% from the original 1.25kg CO2e/m3 to 1.16kg CO2e/m3. However, the replacement of chemicals with low carbon emission factors has led to an increase in operating costs. The company studied has suspended the implementation of this method based on cost considerations. Dosing analysis shows that the pH sensor placement position can affect the repeated addition of drugs to the chemical. After improving the pH sensor placement point, the consumed quantity of chemicals decreased and the total carbon emissions decreased from the original 1.25kg CO2e/m3 to 1.15kg CO2e/m3, and the total carbon emissions decreased by about 10%. In addition, the cost is also reduced by 3,428 dollar/ year. As a result, both the reduction of carbon emissions and the cost reduction can be achieved.
In recent years, many countries have proposed ways to calculate the quantity of carbon emissions.
From the results of the calculation of carbon emissions, it can be pointed out which industries have the largest emissions to carbon dioxide production, and the actions can be then taken to get the maximum effectiveness of carbon emission reduction.
In this research, “Carbon Footprint Computation Guidelines” is used for the case study. The study of total carbon emissions from the degreasing wastewater treatment of the case company was based on energy resources, chemicals and consumables. The purpose is trying to find the chemical unit with the highest carbon emissions and to reduce its emissions. The results show that the chemical unit has the largest emission. Using sensitivity analysis for experiments simulations of reducing the carbon emission coefficient of chemicals and the use of chemicals separately, are carried out to determine whether the total emissions can be reduced.
From the simulations, chemicals of low carbon emission factors were chosen. Total carbon emissions decreased about 7.2% from the original 1.25kg CO2e/m3 to 1.16kg CO2e/m3. However, the replacement of chemicals with low carbon emission factors has led to an increase in operating costs. The company studied has suspended the implementation of this method based on cost considerations. Dosing analysis shows that the pH sensor placement position can affect the repeated addition of drugs to the chemical. After improving the pH sensor placement point, the consumed quantity of chemicals decreased and the total carbon emissions decreased from the original 1.25kg CO2e/m3 to 1.15kg CO2e/m3, and the total carbon emissions decreased by about 10%. In addition, the cost is also reduced by 3,428 dollar/ year. As a result, both the reduction of carbon emissions and the cost reduction can be achieved.