環保署測站細懸浮微粒(PM2.5)自動與手動儀器比對之研究
Comparison between automatic and manual instruments of fine particulate matter(PM2.5) at the Environmental Protection Administration stations
摘要
本研究資料蒐集自環保署空氣品質監測網 2013~2017年全國
細懸浮微粒(PM2.5)之監測數據、自動與手動測站比對關係式及其校正之判定係數R2值,研究中針對細懸浮微粒(PM2.5)自動與手動測站之判定係數R2值與測站距離進行檢定。透過Z檢定分析方法,檢定各測站判定係數R2值與測站距離之顯著性,並以 t 檢定交叉比對樣本平均數是否達到顯著水準。若要使自動與手動判定係數R2≧0.90,則自動與手動測站最短的距離為9.0公里以內;而若要使自動與手動判定係數R2≧0.80,則最短的測站距離為27.8公里以內,該檢定距離符合環保署原先設定之R2>0.80且25公里,但實際運作時有四個測站(臺西、埔里、麥寮、關山)是超過27.8公里的,有部分測站之判定係數R2值偏低(埔里站R2平均等於0.73)。研究發現,部分測站如恆春、彰化、新營等判定係數R2值正逐年遞減中,其中以恆春站逐年下降情形最為顯著(2017年R2為0.63)。環保署截至2019年4月底止已更新五個測站為符合FEM規範的新儀器,其中林園站新儀器PM2.5之平均值較舊儀器平均值高。林園站、崙背站新儀器之判定係數R2優於舊儀器,其餘測站新舊儀器測值沒有明顯差異。
細懸浮微粒(PM2.5)之監測數據、自動與手動測站比對關係式及其校正之判定係數R2值,研究中針對細懸浮微粒(PM2.5)自動與手動測站之判定係數R2值與測站距離進行檢定。透過Z檢定分析方法,檢定各測站判定係數R2值與測站距離之顯著性,並以 t 檢定交叉比對樣本平均數是否達到顯著水準。若要使自動與手動判定係數R2≧0.90,則自動與手動測站最短的距離為9.0公里以內;而若要使自動與手動判定係數R2≧0.80,則最短的測站距離為27.8公里以內,該檢定距離符合環保署原先設定之R2>0.80且25公里,但實際運作時有四個測站(臺西、埔里、麥寮、關山)是超過27.8公里的,有部分測站之判定係數R2值偏低(埔里站R2平均等於0.73)。研究發現,部分測站如恆春、彰化、新營等判定係數R2值正逐年遞減中,其中以恆春站逐年下降情形最為顯著(2017年R2為0.63)。環保署截至2019年4月底止已更新五個測站為符合FEM規範的新儀器,其中林園站新儀器PM2.5之平均值較舊儀器平均值高。林園站、崙背站新儀器之判定係數R2優於舊儀器,其餘測站新舊儀器測值沒有明顯差異。
In the study, the 2013 to 2017 fine particulate matter (PM2.5) data were collected from the Environmental Quality Monitoring Network of Taiwan Environmental Protection Administration (TEPA). The relationship of PM2.5 data obtained from automatic and manual instruments were compared and their R2 values were statistically evaluated. The Z-test analysis method was used to verify the significance of the R-squared value of each station and the distance of the station, and the t-test was used to determine whether the significant level was reached. The results showed that if the target was to obtain R2≧0.90 between the data of automatic and manual intruements, then the distance between the automatic and manual stations should be less than 9.0 km. And if the target was to obtain R2≧0.80, then the distance between the automatic and manual stations should be less than 27.8 km. This meets TEPA's original setting of R2>0.80 and distance within 25 km. However, in the actual operation, there are four stations (Taxi, Puli, Maibu, Guanshan) which distances are larger than 27.8km, and some stations have low R2 values (for example, the average R2 of Puli station is 0.73). This study found that the R2 values of some stations such as Hengchun, Changhua and Xinying are decreased year by year, among which the Hengchun station is the worst (R2 is 0.63 in 2017). The TEPA has replaced five stations with new instruments to comply with FEM specifications as of April 30, 2019. It reveals that only the average PM2.5 data of Linyuan station from new instrument are higher than that from the old one. Only the R2 of the new FEM automatic instrument vs. FRM of Linyuan Station and Lunbei Station are better than their R2 from old automatic instrument vs FRM.