水錶黃銅鑄件金相組織對脫鋅腐蝕潛勢與積垢生成影響之研究
Effect of metallographic structure of yellow brass in the meter on its dezincification potential and scaling
摘要
國內常使用之水錶黃銅鑄件是最容易發生脫鋅腐蝕的α + β雙相黃銅,在配水系統中可能會有脫鋅腐蝕並引起積垢生成的問題,導致水費超收及引起飲水衛生疑慮。黃銅鑄件中的元素組成、鑄造方式會影響其金相組織,進而影響水錶黃銅鑄件的脫鋅腐蝕潛勢及積垢生成。本研究主要探討不同廠牌水錶黃銅鑄件其金相組織上的差異對脫鋅腐蝕潛勢及積垢生成的影響。分析坤慶、源泰、銓準及儀鎮四家廠牌水錶金屬元素組成、金相組織中的晶粒尺寸及相分布,並同時進行脫鋅腐蝕深度實驗及計算脫鋅因子,以評估各廠牌水錶黃銅鑄件脫鋅腐蝕潛勢。再與北部自來水用戶積垢水錶之積垢生成情況進行比較,以探討不同金相組織的水錶黃銅鑄件對積垢生成的影響。
研究結果顯示,四家廠牌水錶在合金組成相似,在金相組織卻有顯著的差異。在晶粒尺寸上,坤慶水錶不論是α相或β相皆顯著高於另三家水錶;在相分布上則是以源泰水錶的黃銅β相有較多的佔比。脫鋅腐蝕潛勢評估部分,坤慶水錶的脫鋅腐蝕深度(1127 ± 42.3 μm)和脫鋅因子(1.65 ± 0.01)為最高,儀鎮水錶腐蝕深度為699 ± 55.4 μm,脫鋅因子為0.73 ± 0.11;源泰(234 ± 38.3 μm、0.38 ± 0.01)及銓準水錶(301 ± 84.8 μm、0.30 ± 0.01)則相對較低。瑞芳地區現地用戶水錶的觀察結果發現坤慶水錶的積垢生成最為嚴重,僅次為源泰及銓準水錶,而儀鎮水錶最輕微。顯示無論是脫鋅腐蝕潛勢(脫鋅腐蝕深度與脫鋅因子)抑或是積垢生成嚴重程度,皆以晶粒尺寸最大的坤慶水錶為最高。綜上所述,表示在水錶的金相組織中,晶粒尺寸對水錶脫鋅腐蝕潛勢及積垢生成有較大的關聯性。
研究結果顯示,四家廠牌水錶在合金組成相似,在金相組織卻有顯著的差異。在晶粒尺寸上,坤慶水錶不論是α相或β相皆顯著高於另三家水錶;在相分布上則是以源泰水錶的黃銅β相有較多的佔比。脫鋅腐蝕潛勢評估部分,坤慶水錶的脫鋅腐蝕深度(1127 ± 42.3 μm)和脫鋅因子(1.65 ± 0.01)為最高,儀鎮水錶腐蝕深度為699 ± 55.4 μm,脫鋅因子為0.73 ± 0.11;源泰(234 ± 38.3 μm、0.38 ± 0.01)及銓準水錶(301 ± 84.8 μm、0.30 ± 0.01)則相對較低。瑞芳地區現地用戶水錶的觀察結果發現坤慶水錶的積垢生成最為嚴重,僅次為源泰及銓準水錶,而儀鎮水錶最輕微。顯示無論是脫鋅腐蝕潛勢(脫鋅腐蝕深度與脫鋅因子)抑或是積垢生成嚴重程度,皆以晶粒尺寸最大的坤慶水錶為最高。綜上所述,表示在水錶的金相組織中,晶粒尺寸對水錶脫鋅腐蝕潛勢及積垢生成有較大的關聯性。
In Taiwan, yellow brass in the meter is α + β duplex brass, which is susceptible to dezincification. The dezincification and the subsequent scaling of brass water meter frequently occur in the drinking water distribution system. The scaling of water meters could result in higher water bill and drinking water safety concerns. There are multiple factors that might influence the metallographic structure, including element composition and casting method, resulting in different dezincification potentials (DPs) and scaling. This study aims to investigate the effect of different metallographic structure on DP and scaling. Four brands of water meters including Kuen-Chin, Yuan-Teai, Chuan-Chan, and Yi-Tzen were chosen. They were analyzed based on their element compositions, depths of dezincification (DD) and dezincification factor (DF). In addition, grain size and phase distribution of metallographic structure from four brands on the meters were also observed to evaluate respective DP. Finally, the results were compared with those scaling meters from northern household to investigate the effect of metallographic structure on scaling.
The results showed that the alloy composition for each brand of meter is very similar while Kuen-Chin and Yuan-Teai revealed the largest grain size and the highest proportion of β phase regarding to the metallographic structure of the meter, respectively. The DP including DD and DF from high to low was as follows: Kuen-Chin (DD: 1127 ± 42.3 μm, DF: 1.65 ± 0.01), Yi-Tzen (DD: 699 ± 55.4 μm, DF: 0.73 ± 0.11), Yuan-Teai (DD; 234 ± 38.3 μm, DF: 0.38 ± 0.01) and Chuan-Chan (DD: 301 ± 84.8 μm, DF: 0.30 ± 0.01). The household water meters in Ruifang showed that Kuen-Chin with the largest grain size presented the highest DP and the most severe scaling. To conclude, the grain size of yellow brass in the water meter is the crucial parameter that could influence the DP and scaling.
The results showed that the alloy composition for each brand of meter is very similar while Kuen-Chin and Yuan-Teai revealed the largest grain size and the highest proportion of β phase regarding to the metallographic structure of the meter, respectively. The DP including DD and DF from high to low was as follows: Kuen-Chin (DD: 1127 ± 42.3 μm, DF: 1.65 ± 0.01), Yi-Tzen (DD: 699 ± 55.4 μm, DF: 0.73 ± 0.11), Yuan-Teai (DD; 234 ± 38.3 μm, DF: 0.38 ± 0.01) and Chuan-Chan (DD: 301 ± 84.8 μm, DF: 0.30 ± 0.01). The household water meters in Ruifang showed that Kuen-Chin with the largest grain size presented the highest DP and the most severe scaling. To conclude, the grain size of yellow brass in the water meter is the crucial parameter that could influence the DP and scaling.