應用熔射覆膜技術之摩阻型接合其螺栓排列於滑移行為之影響
Effect of Bolt Arrangement on Slip Behavior of Slip-Critical Connections with Thermal Sprayed Coating
摘要
本研究應用熔射覆膜技術於鋼板接合面以提升滑移係數,增加摩阻型螺栓接合強度,並探討螺栓排列對接合強度之影響。採用八顆高強度螺栓之摩阻型接合進行滑移實驗,探討螺栓在不同矩陣排列下對滑移係數、螺栓預拉力、連接板應變值及摩阻力的影響。試體採用150 𝜇m鋁鎂熔射覆膜於連接板接合面,八顆螺栓以四種排列組合配置(1×8、2×4、4×2、8×1)。實驗結果顯示,不同螺栓排列之滑移係數介於0.76至0.89,平均為0.85,高於規範規定噴砂後未塗裝之滑移係數0.5。各試體之八顆螺栓平均預拉力損失率介於12.9%至15.6%間,整體平均為14.1%,螺栓排列型式對其預拉力損失無明顯規則。接合於不同斷面之滑移量由接合中央向兩端遞增,於接合較長之多列單行排列型式下尤其明顯。達滑移載重時,連接板垂直於載重方向之斷面,應變值由摩阻型螺栓接合處中央向兩側遞減。連接板沿載重方向之各斷面應變值受到摩阻力分佈影響,每經過一列摩阻型螺栓,應變值明顯增加。隨載重上升,於螺栓排列較方正之試體,螺栓摩阻力皆穩定增加,螺栓排列為單列或單行之試體,螺栓摩阻力則相互消長。不同螺栓排列型式之滑移係數無顯著差異,皆可提升接合強度,但會造成接合斷面滑移量與螺栓提供摩阻力之差異。
In this study, thermal sprayed coating was applied to the faying surface of steel plates in order to increase the slip coefficient and enhance the slip resistance of the slip-critical joint. Moreover, this study aims to explore the effect of bolt arrangement on slip resistance. Slip tests of slip-critical connection using eight high-strength bolts were carried out to explore the effects of different bolt arrangement on the slip coefficient, bolt pretension, stress on the splice plate, and slip resistance. Splice plates of the specimens were thermal sprayed coated with 150 𝜇m aluminum-magnesium alloy. Eight bolts were arranged in four combinations of permutations (1x8, 2x4, 4x2, 8x1). The test results showed that the slip coefficients of different bolt arrangement ranged from 0.76 to 0.89, and the average slip coefficient was 0.85 that was much higher than the slip coefficient 0.5 of unpainted blast-cleaned steel surface that specified in the code. The average ratios of bolt pretension loss for the eight bolts in each specimen were between 12.9 and 15.6% with an average of 14.1%, indicating that the bolt pretension loss is no affected by the bolt layout. The slip at different connected section was incremented from the joint center to the both joint ends, especially in the multi-row single-column arrangement. When slip load occurred, the strain on splice plate of the section perpendicular to the load direction was reduced from the joint central to both ends. In load direction, the strain of each section on splice plate was affected by slip resistance distribution. The strain increased apparently on the section beyond each row of slip-critical bolts. As the load increased, the slip resistance of the specimens having much squarer bolt layout increased steadily, however the slip resistance of specimens having bolts in single row or column mutually grew and declined. Different bolt arrangement had no significant difference on the slip coefficient and all the specimens could enhance strength of connection. However, different bolt arrangement will result in different slip and slip resistance at different sections.