X形肋條應用於梯形內冷卻流道之熱傳可視化研究
Heat transfer visualization inside trapezoidal internal cooling channel with X-shaped ribs
摘要
肋條為常應用於內流道的結構,用以提升內流道的熱傳效果。本實驗使用截面為直角梯形之雙面加熱的垂直流道,在加熱面上放置正V形、完整X形,以及前短後長指向上游的X形與前長後短指向下游的X形兩種改良型X形肋條,肋條高度對流道水力直徑比為0.128,肋條間距對肋條高度比為10或20,以乾燥空氣作為冷卻流體,雷諾數控制為10000~40000,並使用紅外線熱像儀來探討在梯形流道內,各種不同形狀之肋條在單排肋條對齊排列以及多排肋條交錯排列下對熱傳的影響。實驗結果顯示,在梯形流道中,靠近上底處的截面積較小,使局部流體流速加速,導致接近上底處的熱傳較好,而在斜面下緣,因接近下底處,由於銳角區兩側的邊界層重疊,導致局部流體流速變慢,壓力上升,使流體難以流入,致使該區域之熱傳明顯比接近上底處差。在單排肋條時,完整X形肋條能在肋條中段靠近兩側壁面處及肋條後方形成比其他形狀肋條更大的高熱傳區,故熱傳效果最佳,效果比V形肋條高11~15%。在交錯排列下,P/e=20之完整X形肋條的熱傳效果足以與P/e=10之V形肋條媲美,但因其造成的壓力損失過大,故其熱性能較差。結論而言,在單排與多排肋條排列中,縱使完整X形肋條具有最大高熱傳區域,相較摩擦係數最大的完整X形肋條,改良型X形肋條具有較低的摩擦係數,且維持了一定的熱傳效果。
To enhance heat transfer performance, rib has been widely applied to channel wall. In our research, vertical cooling channel with cross section of right angle trapezoid has been considered. Heater and rib were applied to the right angle wall and inclined wall with rib height-to-hydraulic diameter as 0.128. Ribs with V-shaped, full X-shaped and modified X-shaped which pointing upstream and downstream had been investigated. Dry air was applied as the cooling fluid, and the Reynolds numbers were from 10000~40000. Infrared camera (IR camera) has been used to capture the temperature distribution of different rib types, including single rib and staggered arrangement with two rib spacing (P/e=10 and 20). Result shows, at right angle wall of the trapezoid channel, zones near the shorter side with smaller cross section area, fluid has been squeezed and speeded up, causing higher heat transfer. At the bottom edge of the inclined wall, the flow was blocked by the sharp angle of the corner, resulting in lower heat transfer comparing to upper edge of the inclined wall. For the case of single rib, full X type has the larger high heat transfer region located at middle part of the rib and downstream area. Its Nusselt number ratio is 11~15% higher than V-shaped rib. For staggered arrangement, full X with P/e=20 has comparable heat transfer comparing to V rib with P/e=10. However, the friction factor of X rib is a drawback because higher friction factor causes lower thermal performance. In conclusion, in single rib and staggered arrangement, despite full X rib has larger and higher heat transfer region, modified X ribs decrease the friction factor and successfully maintain acceptable thermal performance.