利用不同長度之光纖束減少內視鏡雷射照明光斑

Using varying length of fiber bundle to reduce the laser speckle of endoscope illumination source

檔案

日期

2019

類型

語言

中文

摘要

為了在維持足夠亮度的前提下縮小截面積,我們以高同調性的半導體雷射作為光源,但也伴隨著光斑產生的問題。高同調性光源在傳遞到屏幕或是受測物的過程中,由於物體表面的不光滑,會讓散射光有干涉的現象,而影響影像判讀。因此減少光斑以提升影像清晰度為本實驗目標。
本實驗室利用了特製光纖、蜂鳴器以及雷射除光斑器降低光斑。特製光纖是由數根不同長度之光纖所組成之光纖束,每根光纖長度差異為雷射光的同調長度之倍數。三種方法都是利用改變光傳遞的模態,進而達到降低雷射光源同調性,降低了光源同調性,也就降低了光斑的產生。再將各方法所得之影像進行信噪比及平坦度的分析。
結果顯示特製光纖的去光斑效果最好,可以得到最均勻的影像。相比於使用單根光纖時的高光斑對比度影像,此方法可以清楚看見受照物,但當我們將兩種光纖分別導入進內視鏡耳鏡時,影像中幾乎看不到光斑,基於此原因,我們猜想,由於耳鏡為每根光纖長度相同的光纖束,特製光纖束之所以能降低光斑對比度的主要原因應是空間上的分布的差異,多根光纖將一個點光源分散成多個點光源,而每個點光源都會產生光斑,在多重光斑的疊加下,光斑對比度則相對不明顯。
特製光纖,沒有蜂鳴器的噪音,使用上也比雷射除斑器方便。可應用於本實驗室所開發之超細內視鏡,將特製光纖應用於超細內視鏡不僅可提供足夠的光源,同時降低衍出光斑的問題。未來若能提升此特製光纖的堅固性,相信具有發展成為商品的潛能。
In order to not only reduce the section of endoscope but also maintain sufficient brightness. We utilize a high coherent semiconductor laser as the light source. But it also accompanies speckle generation. When the high coherent light source transmitts to the screen or the object, the surface of the object is not smooth, resulting in the scattered light to interfere, which affects the image quality. Therefore, reducing the speckle to enhance image clarity is the goal of the experiment.
We use customized fiber, buzzer, and laser speckle reducer to lower speckle contrast. The customized fiber is made by fiber bundle. Each fiber with different lengths. The difference of length is a multiple of the coherence length of the laser light. These three methods the change the mode of the light transmission, thereby reducing the coherent of the laser source. Due to reduce the coherent of the light source, reducing the generation of the speckle. And analysis the image obtained by each method by signal-to-noise ratio and flatness.
The result show that the customized fiber obtains the best speckle removal and the most uniform image. Compared to the high speckle contrast image from using single fiber. This method can observe the object clearly. But when we introduce the two fibers into the otoscope, it’s almost without speckle pattern in the image. Base on this reason, we speculate that the special fiber bundle can reduce the spot contrast should be the difference in spatial distribution instead of temporal delay. As the otoscope is the fiber bundle with same length of each fiber. Fibers split one source into multiple light source. Each light source may generate speckle pattern. According to the superposition of all speckle, the spot contrast is lower.
Customized fiber, without noise, and more convenient than laser speckle reducer. It can be applied to ultra-slim endoscope developed by us. The application not only provides sufficient brightness but also reduces the problem of speckle. It has the potential to develop into a commodity by improving the stability.

所屬典藏

生醫光電研究所
顯示完整詮釋資料 統計資料

引用此條目

易柏維 (2019). 利用不同長度之光纖束減少內視鏡雷射照明光斑. https://thesis.lib.nycu.edu.tw/handle/20.500.14371/72508

BibTeX RIS

引用文字依 APA 第 7 版格式自動產生,使用前請再核對。

分享

永久網址:https://thesis.lib.nycu.edu.tw/handle/20.500.14371/72508