探討曲折角度與流速對微流混合之影響
Experimental Study on the Effect of Zigzag Angle and Flowrate for Microfluidic Mixing
摘要
微流混合是生醫晶片上重要技術之一,好的混合可以強化晶片上化學反應及量測的穩定性,近十年的文獻中提出了各式微混合理論與構想,其中被動式鋸齒形通道混合因容易應用以及結構簡單,為本研究重心。本研究將以實驗為基礎,從實際的結果來探討鋸齒形通道的曲折角度與流速對被動式微流混合的影響。實驗前先在Autodesk CFD環境模擬從0度到75度六種不同角度之曲折通道於不同流速下的混合效果,模擬結果顯示,除了0度曲折通道中混合程度會隨著流速增加而變差外,其他所有角度下混合程度皆隨著流速增加先變差再變好。實驗則分為兩個部分,第一個部分先以微奈米技術製作與模擬尺寸相同的六種微流曲折通道,作為測試不同流速下的實驗平台。測試流速範圍跨越三個級數,從0.001 ml/min至1.0 ml/min(0.308<Re<308)。實驗結果顯示,混合的趨勢與模擬結果類似。例如75度通道在40 mm的混合長度後,在實驗中依流速低到高其混合程度從92%降至29%再升高至90%。第二部分探討壁面親水性對混合的影響,實驗中利用電漿以及鐵氟龍塗層改變通道管壁的親/疏水性,結果顯示兩種改質都對混合有幫助,尤其以疏水通道幫助更為明顯,混合程度最高增加24%。本研究結論如下,當混合環境雷諾數小於30時,曲折角度的設計與混合程度沒有顯著的關係,越長的通道即能達到越好的混合效果;當雷諾數大於30時,角度的變化就顯得非常關鍵,角度越大混合越好。此外,管壁改質實驗結果指出,在通道表面親水與疏水處理後均能提高混合程度,其中疏水處理效果較為顯著。
Microfluidic mixing is an important technique in biomedical applications. Good mixing can enhance the chemical reaction and the stability of the measurement on the chip. In the last decade, various micro-scale mixing theories and ideas have been proposed. The passive approach with a zigzag channel is one of the most popular methods because it is easy to apply and is simple in structure. This work aims to reveal the performance of microfluidic mixing with different zigzag angles through experiments. Before the experiments, the mixing of the zigzag channels from 0 to 75 degrees is simulated at different flowrates in a commercial software of computational fluid dynamics. The simulation results show that the channels of all angles, except the one with zigzag angle of 0 degree, demonstrate a consistent tendency, that the mixing performance is first reduced and later improved with the increase of flowrates. Experimental investigations include two parts. In the first part, six different channels with different zigzag angles were testing with the same sets of flowrates. The span of the flowrates is from 0.001 ml/min to 1.0 ml/min (0.308<Re<308). The results show that the tendency is similar to the simulations results. For example, the mixing performance is initially 92% at 0.001 ml/min and is gradually reduced to 29% when the flowrate is up to 0.1 ml/min. When the flowrate is greater than 0.1 ml/min, the mixing performance increases with the flowrate until 90%. In the second part, experiments of different boundary conditions are investigated for possible influence to the mixing performance. The surface hydrophilicity of microfluidic channel is modified with plasma treatment and Teflon coating for hydrophilic and hydrophobic channels, respectively. The results show that both the methods can improve mixing performance, especially the hydrophobic channel for 24% improvement in mixing. According to the experimental results, we found that the mixing performance is independent of the zigzag angle in low-speed regime where the Reynolds number is less than 30. When Reynolds number is more than 30, a greater zigzag angle would effectively improves the mixing. In addition, the experimental results of wall modification indicate that the mixing can be enhanced with either hydrophilic or hydrophobic treatment.