摘要

本研究探討一種新型複合式散熱系統,此種新型複合式散熱系統結合了電暈風效應及靜電致動器原理,在運作時會施加高電壓於片狀電極,使片狀電極在運作過程中產生電暈風,同時利用靜電感應使片狀電極產生類壓電風扇之振動行為,結合兩種散熱系統之特性藉此達到熱傳增強效果。本研究亦針對放電電極之幾何設計,在電暈風散熱系統下測試平式電極與尖式電極之散熱效果,其中尖式電極之設計參數包含尖點夾角、尖點數目及尖點距離,且利用最佳設計之電極進行複合式電暈風散熱實驗,測試其散熱增強效果。本研究之加熱片輸入功率固定為15 W、感應板向後偏移固定為30 mm,實驗參數包含電極間距10~20 mm、輸入電壓4~18 kV、高壓電阻7.5~30 GΩ、感應板間距2~3.5 mm。在電暈風散熱系統實驗結果發現,當尖式電極之尖點夾角越小,或是尖點數目越多,熱傳效果越好,其中尖點夾角15˚、尖點數目3之尖式電極在電極間距10 mm、電暈電壓10 kV時,熱傳係數為31.77 W/m2-K,較平式電極增加10.94 %。在複合式電暈風散熱系統實驗結果發現,在低電暈電壓下,複合式電暈風系統之散熱效果大於電暈風系統,其散熱效果隨著電壓上升而減弱。平式電極與尖點夾角15˚、尖點數目3之尖式電極在電極間距10 mm時,複合式電暈風系統之熱傳係數相比於電暈風系統最大提升分別為10.52 %、6.46 %。
This study discusses a new type of cooling system which combines the effects of corona discharging and electrode vibration. A high voltage was applied to a thin copper plate which will generate the corona discharge effect as an emitting electrode. The emitting electrons vibrated as the blades of a piezoelectric fan due to the electrostatic force. The aim of this study is to combine the phenomena mentioned above to achieve an improved hybrid cooling system.
In this study, two emitting electrodes were tested with the corona effect, which are a flat electrode and a tip electrode. Besides, the tip angle, amount and the distance between tips of the tip electrode were also investigated to find the optimal design of a tip electrode. With the optimal design of the emitting electrodes, the hybrid cooling system was compared with an EHD cooling system. Parameters tested in this study include the inter-electrode gap (10~20 mm), the corona voltage (4~18 kV), the high-voltage resistance (7.5~30 GΩ), and the induction plate gap (2~3.5 mm). The induction plate offset distance is fixed at 30 mm and the input power is fixed at 15 W.
In the electrode design test, the heat transfer effectiveness was increased with smaller electrode tip angle. The electrode which has more tips also increased the heat transfer effectiveness. The electrode with 15˚and 3 tips had the maximum heat transfer coefficient with 10 mm inter-electrode gap and 10 kV corona voltage. The heat transfer coefficient was 31.77 W/m2-K, which was 10.94% higher than the flat electrode. The experimental results of the hybrid cooling system show that under low corona voltage condition, the heat transfer effectiveness of the hybrid cooling system is greater than the EHD cooling system. With the corona voltage rising, the heat transfer effectiveness was weaken. When the inter-electrode gap equals to 10 mm, the heat transfer coefficient ratio of the flat electrode and the electrode with 15˚and 3 tips are 10.52% and 6.46%.

所屬典藏

機械工程學系
顯示完整詮釋資料 統計資料

引用此條目

秦斈函 (2019). 複合式電暈風散熱系統之電極設計與熱傳分析. https://thesis.lib.nycu.edu.tw/handle/20.500.14371/73282

BibTeX RIS

引用文字依 APA 第 7 版格式自動產生,使用前請再核對。

分享

永久網址:https://thesis.lib.nycu.edu.tw/handle/20.500.14371/73282