提升微粒式數位微流體免疫檢測晶片可靠度之研究

Reliability Improvement of a bead-based digital microfluidic immunochip

檔案

全文未公開。

日期

2019

類型

語言

中文

摘要

IVF (In Vitro Fertilization)技術是目前治療不孕症的主要方式,此方法能夠治療全世界約10%的不孕症患者,而目前胚胎的選擇多主要是依靠胚胎的型態來判斷胚胎發育成熟度。根據文獻指出,胚胎成長因子如IL-1β可能可以用來判定胚胎成長情形。因此,若能發展出量測胚胎成長因子濃度變化之技術,用此技術來輔佐胚胎選擇就能提升胚胎選擇效率。然而,傳統的生物因子免疫分析法樣本需求量過大,需多個胚胎培養液一起量測或經過多倍稀釋才能量測。
本實驗室所開發之少磁珠數與磁珠聚集之磁珠數數位微流體免疫檢測晶片,相較於傳統的免疫檢測方式具有低樣品體積、反應時間短及高偵測靈敏度等優點,可滿足單顆胚胎培養液 Human IL-1β 之檢測。然而數位微流體免疫晶片仍存在生物沾黏及介電崩潰等問題,導致進行免疫反應檢測時晶片損壞率高。
本研究旨在提升微粒式數位微流體免疫檢測晶片可靠度。結果顯示,相較於空氣環境晶片,石蠟油環境中進行免疫反應可降低生物沾黏情況,產生液滴之時間十分穩定,也改良之液體注入方法為液滴於晶片上下板側邊注入再由電濕潤力拉入晶片內,操作上十分簡單且提高了液滴注入晶片之成功率,接著設計之磁鐵控制機構可解決免疫反應過程需人為拿持磁鐵去聚集與混合磁珠時之不便。經過上述改良後晶片每次進行免應檢測之過程僅需40分鐘(液滴注入至量測結束),且晶片免疫檢測完成之成功率達95%,並建立 Human IL-1β 之檢量線,其偵測極限為1.22 pg/mL。
關鍵字:In Vitro Fertilization、胚胎成長因子、數位式微流體晶片、生物沾黏
In Vitro Fertilization (IVF) is the main treatment for infertility. This method can treat about 10% of infertility patients around the world. Currently, the selection of embryos only relies on the morphology features. According to the literature, Embryonic growth factor such as IL-1β in the embryonic culture medium can be used as a basis for judging embryonic development and predicting pregnancy rate. Therefore, by measuring the embryonic growth factor have opportunity to improve the efficiency of embryo selection. However, traditional immunoassay required sample volume was larger than the volume we can get from the culture medium of embryo.
Our laboratory has developed the bead-based digital microfluidic immunoassay with low sample requirement, low limit of detection and rapid immunoassay. In the previous work, this technique has successfully measured the embryonic growth factor IL-1β. However, manipulating protein droplets on digital microfluidic chip coated with hydrophobic layer may arise biofouling problem and result in chip damage.
This study aims to improve the reliability of bead-based digital microfluidic immunochip. The result shows that the immunoassay process in the paraffin oil environment can reduce the biofouling problem, and the droplets generation is very easy and stable. The improved liquid injection method is to inject droplets into the gap between top plate and bottom plate of the chip and then pulled into the chip by the electrowetting force. This method is very easy to operate and can increase the success rate of droplet injection into the chip. The magnetic operation mechanism is designed to assist the immunoassay reaction process and solve the inconvenience of the magnet manipulating by hands. With improvements mentioned above, the time of whole immunoassay reaction take only 40 minutes. The success rate of the immunoassay process can reach 95%. Finally the human IL-1β calibration curve is established and the limit of detection is 1.22 pg/mL.
Key Words: In Vitro Fertilization, Embryonic growth factor, Digital microfluidic, Biofouling

所屬典藏

機械工程學系
顯示完整詮釋資料 統計資料

引用此條目

許中宥 (2019). 提升微粒式數位微流體免疫檢測晶片可靠度之研究. https://thesis.lib.nycu.edu.tw/handle/20.500.14371/73290

BibTeX RIS

引用文字依 APA 第 7 版格式自動產生,使用前請再核對。

分享

永久網址:https://thesis.lib.nycu.edu.tw/handle/20.500.14371/73290