蛋白質分子表面固定化分佈對於單晶矽奈米線生物感測晶片電性的影響
The influence of the surface spatial distribution of immobilized proteins on the electrical properties of single-crystal nanowire bioFET Chip
摘要
隨著科技的不斷進步,擁有超高靈敏、即時量測和免標記等優點的矽奈米線場效電晶體(SiNWFET) 被認為是一個非常具有發展性的生物傳感器(biosensor)。矽奈米線場效電晶體典型的運作原理是先將閘極氧化層表面固定化上一層自組裝單分子膜(SAM)來抓住生物探針像是核酸或是抗體,共同認知的偵測方式,是藉由直接量測奈米線上生物標的物結合後產生的電場變化。但是利用掃描式電子顯微鏡 (SEM) 觀察到生物探針固定化大部分是隨機分布出現在晶片表面上,少部分出現在奈米線上。不過目前在奈米現場效電晶體的研究中,正確的訊號可以重複出現並且成功的偵測到。因此,我們提出一個假設,即使生物標的物與探針的結合出現在奈米線周遭的表面,而不是出現在奈米線表面,也有可能可以偵測到訊號。在此研究中,我們利用互補式金屬氧化物(CMOS)兼容的製程技術來製作出單晶矽的奈米線場效電晶體,也就是矽在絕緣襯底上 (SOI) 元件,即利用高摻雜矽襯底用來做為背柵(back-gate)電極,通過電容耦合效應(capacitive coupling effect)來電調製奈米線電導,藉由結合矽奈米線場效電晶體進行抗體抗原結合的生物感測,與原子力顯微鏡(AFM)的表面形貌呈現功能,來了解生物標的物與探針在奈米線周遭表面結合對於電性感測造成的影響。我們所選擇的生物標的物與探針是B型肝炎病毒 (hepatitis B virus, HBV) X蛋白 (HBX)與其抗體。抗體抗原的專一性結合首先利用酶聯免疫吸附測定(ELISA)來確認,對於生物探針固定化的方法則是利用氧電漿(Oxygen plasma)、3-氨基丙基三乙氧基矽烷(APTES)和戊二醛(GA)的來提供可以互相連結的接上的官能基並接上抗體探針。然後在採用原子力顯微鏡對於化學及生物分子修飾的二氧化矽或是矽襯底的表面形貌進行分析。在此研究中,檢測到矽奈米線場效電晶體系統的偵測極限(LOD)是100 fg/mL。並通過原子力顯微鏡和電性號檢測交叉驗證,檢測在矽元件上抗體抗原的結合。這些證據不僅讓我們了解蛋白質分子固定化後的空間分布對奈米線場效電晶體的電學特性的影響,並且對於生物傳感器(bioFETs)的開發及生物電子學與生物傳感器領域發展至關重要。
During the development of detection technology, it is found that silicon nanowire field effect transistor (SiNWFET) possesses extraordinary characteristics, including ultra-high sensitivity, real-time detection and no need for labels, and is considered a promising biosensor. For a typical SiNWFET detection, the gate oxide surface will first be functionalized with a self-assembled monolayer (SAM) to immobilize biological probes such as DNA or antibodies. In the general consensus, the measurable signal is then produced when the binding of the analytes occurs directly on the nanowire. However, it was observed through scanning electrical microscopy (SEM) that most of the immobilization occurs on the device surface rather than on the nanowire and was randomly distributed. Nevertheless, throughout the many studies done on SiNWFETs, reproducible successful measuring results are obtainable. Therefore, the hypothesis of this study is that the probe-target binding on a surface with a close proximity to the nanowire might also contribute detecting signals. By combining the SiNWFET platform bio-sensing with surface topography obtained through atomic force microscopy (AFM), this research is aimed to understand the effect that probe-target binding near the nanowire surface has on the SiNWFET electrical property. We demonstrated CMOS-compatible process techniques for the fabrication of single-crystal SiNWFETs, so called silicon on insulator (SOI). Highly doped Si substrate served as the back-gate electrode for electrically modulating the nanowire conductance through the capacitive coupling effect. We introduced HBV X protein (HBx) and anti-HBx as our study model. For the immobilization process of our system, oxygen plasma, APTES and glutaraldehyde was used to provide different functional groups to connect antibody probes. AFM was then adopted to analyze the surface morphology of chemical/biological molecules-modified SiO2/Si substrate. The LOD of our SiNW bioFET system in this study is 100 fg/mL. With cross-authenticating SiNWFET bio-sensing with AFM surface morphology imaging, the antigen-antibody interaction on the buried oxide surface near nanowire is proved detectable. This evidence not only gives us a better understanding on the influence of the spatial distribution of the proteins on the electrical characteristics of SiNWFET and is also critical for developing bioFETs and the fields of bioelectronics and biosensors.
所屬典藏
生醫工程研究所引用此條目
Weng, Y.-Y. (2020). The influence of the surface spatial distribution of immobilized proteins on the electrical properties of single-crystal nanowire bioFET Chip. https://thesis.lib.nycu.edu.tw/handle/20.500.14371/74697
引用文字依 APA 第 7 版格式自動產生,使用前請再核對。
分享
永久網址:https://thesis.lib.nycu.edu.tw/handle/20.500.14371/74697