咖啡樣品中歐盟優先規範之多環芳香族碳氫化合物的分析檢測和風險評估

Analytical determination and risk assessment of the EU priority polycyclic aromatic hydrocarbons (PAHs) in coffee samples

檔案

日期

2020

類型

語言

中文

摘要

多環芳香族碳氫化合物 (Polycyclic aromatic hydrocarbons, PAHs) 具致癌性和致突變性,在環境中廣泛分佈,也會於食品加工過程中產生。國人飲用咖啡族群龐大,但關於咖啡樣品中 PAHs 的組成和含量尚無完整之研究。本研究建立咖啡中歐盟優先規範的 PAHs 檢測條件,再針對烘焙程度 (淺焙、中焙與深焙) 對咖啡豆中 PAHs 生成的影響與不同沖泡方式 (濾掛 (常壓) 與機器 (高壓)) 對咖啡豆中 PAHs 溶出的影響進行探討,同時檢測市售樣品中 PAHs 含量,以進行台灣民眾飲用咖啡暴露於 PAHs 的健康風險評估。高效能液相層析儀-螢光檢測器 (HPLC-FLD) 對此些 PAHs 的檢測靈敏度高,並可於 18 分鐘內完成檢測 (但 cyclopenta[c,d]pyrene (CPP) 無螢光特性,無法被檢測) 。實驗以生咖啡豆與生咖啡豆沖泡液為背景基質,經 QuEChERS 處理,於優化條件下之回收率為 80 ~ 112% (生咖啡豆加 0.5、1和2 ng/g 之 PAHs) 與 90 ~ 103% (生咖啡豆沖泡液加 1、5和10 ng/mL 之PAHs),重複性及中間精密度之變異係數為 1 ~ 20% 與 7 ~ 32%,方法偵測極限為 0.002 ~ 0.1 ng/g (咖啡豆) 與 0.003 ~ 0.15 ng/mL (咖啡豆沖泡液),方法定量極限為 0.006 ~ 0.4 ng/g (咖啡豆) 與 0.008 ~ 0.5 ng/mL (咖啡豆沖泡液)。PAHs含量隨咖啡豆烘焙程度增加而增加,深焙咖啡豆中的 PAHs 含量為 923.66 ± 31.46 ng/g,淺焙咖啡豆中的 PAHs 含量為 69.35 ± 6 .77 ng/g;咖啡沖泡液中的 PAHs 亦以深焙咖啡沖泡液之含量較高 (濾掛:0.62 ± 0 .09 ng/mL; 機器:2.14 ± 0.11 ng/mL),淺焙咖啡沖泡液之含量較低 (濾掛:0.31 ± 0.02 ng/mL; 機器:0.40 ± 0.03 ng/mL);PAHs 從咖啡豆到其沖泡液之溶出率與沖泡方式 (壓力不同) 呈現正相關,以機器沖泡 (3.94 ~ 10.57%) 較濾掛 (1.14 ~ 7.76%) 為高;又以淺焙咖啡之溶出率 (7.76 ~ 9.84%) 高於深焙咖啡之溶出率 (1.14 ~ 3.94%),顯示 PAHs 從咖啡豆到其沖泡液之溶出率隨烘焙程度增加而有減少趨勢。市售咖啡樣品中 PAHs 含量為 0.23 ± 0.02 ~ 1.23 ± 0.29 ng/mL。本研究針對成年人與老年人兩族群攝食咖啡暴露於 PAHs之健康關注程度進行風險評估,在一般情境與嚴格情境下所有樣品之暴露限值 (Margin of exposure, MOE) 值均大於 10,000,屬於低度健康關注程度,顯示國人喝咖啡暴露於 PAHs 的風險不高。
Polycyclic aromatic hydrocarbons (PAHs) widely distributed in the environment are carcinogenic and mutagenic. PAHs would also be produced during food processing. European Food Safety Authority (EFSA) proposed the EU priority 15+1 PAHs based on 15 PAHs recommended by the Scientific Committee for Food (SCF) and the benzo[c]fluoride (BcL) recommended by the Joint FAO/WHO Expert Committee on Food Additives (JECFA). Coffee is very popular in Taiwan. However, there is no thorough study regarding the composition and content of PAHs in coffee samples. In this study, the determination conditions of the EU priority PAHs in coffee samples were established. Moreover, the effect of roasting degrees on the PAHs in coffee beans (light, medium and dark roast) and the effect of different brewing methods (drip bag brewing (normal pressure) and machine brewing (high pressure)) on the dissolution of the PAHs from coffee beans to their brewing solutions were studied. The levels of PAHs in commercial coffee samples were determined to assess the health risks of Taiwanese people regarding drinking coffee. High performance liquid chromatograph-fluorescence detector (HPLC-FLD) is simple and easy for operation, and has a high sensitivity and moderate operating cost. It was used to analyze the PAHs in coffee samples in 18 min although cyclopenta[c,d]pyrene (CPP) cannot be detected (no fluorescence absorption). The instrument detection limit (IDL) and the instrumental quantitation limit (IQL) values of the PAHs were 0.002-0.1 and 0.005-0.5 ng/mL, respectively. In the work, green coffee bean and green coffee bean brewing solution were used as the respective matrices, and QuEChERS method was used to extract the PAHs from coffee samples. The PAH recoveries were 80-112% (green coffee bean spiked 0.5, 1 and 2 ng/g of PAHs) and 90-103% (green coffee bean brewing solution spiked 1, 5 and 10 ng/mL of PAHs), respectively. The coefficient of variation (CV%) values of the repeatability and intermediate precision for analysis of the PAHs were 1-20% and 7-32%, respectively. The method detection limit (MDL) and the method quantification limit (MQL) values were 0.002-0.1 and 0.006-0.4 ng/g for the coffee bean, and 0.003-0.15 and 0.008-0.5 ng/mL for the coffee bean brewing solution, respectively. The highest and lowest contents of the PAHs in coffee beans were 923.66 ± 31.46 ng/g of the dark-roasted sample and 69.35 ± 6.77 ng/g of light-roasted sample, respectively. The PAH contents in the solutions of the dark-roasted coffee beans brewed by drip bag (0.62 ± 0.09 ng/mL) and machine (2.14 ± 0.11 ng/mL) were the highest; however, the PAH contents in the solution of the light-roasted coffee beans brewed by drip bag (0.31 ± 0.02 ng/mL) and machine (0.40 ± 0.03 ng/mL) were the opposite. PAH contents in coffee beans were increased with the roasting degree. Low dissolution of the PAHs from coffee beans to their brewing solutions were observed, and the dark-roasted coffee bean brewing solution had the highest levels of the PAHs. Besides, high pressure brewing (machine brewing) presented higher dissolution rate of the PAHs (from coffee beans to their brewing solutions) (3.94 ~ 10.57%) than normal pressure brewing (drip bag brewing) (1.14 ~ 7.76%). The dissolution rate of light- roasted coffee (7.76 ~ 9.84%) was higher than dark-roasted coffee (1.14 ~ 3.94%), which shows that the dissolution rate of PAHs from coffee beans to their brewing solution decreased with the roasting degree increasing. The amounts of PAHs in the commercial coffee samples were 0.23 ± 0.02 ~ 1.23 ± 0.29 ng/mL. This study conducted a risk assessment of the public health concerns of coffee exposure to PAHs in adults and elderly population. The margin of exposure (MOE) values caculated for all samples in average and high level consumers were higher than 10,000 (indicating a low concern for human health). Therefore, Taiwanese people were not at high risk of exposure to PAHs when drinking coffee.
顯示完整詮釋資料 統計資料

引用此條目

趙于萱 (2020). 咖啡樣品中歐盟優先規範之多環芳香族碳氫化合物的分析檢測和風險評估. https://thesis.lib.nycu.edu.tw/handle/20.500.14371/75307

BibTeX RIS

引用文字依 APA 第 7 版格式自動產生,使用前請再核對。

分享

永久網址:https://thesis.lib.nycu.edu.tw/handle/20.500.14371/75307