長照機構環境感染管制實例研究

The Case Study of Environmental Infection Control in Long-Term Care Facilities

檔案

日期

2020

類型

語言

中文

摘要

目的:本研究以花蓮地區某公立醫院附設護理之家及某私立老人長期照護中心為研究對象,以機構環境感染管制措施執行現況進行評估,並回饋合適改善建議。
方法:本研究為實例研究,研究期間自109年3月至5月止,以問卷調查、人員訪談、實地訪查及ATP生物冷光檢測法(adenosine triphosphate bioluminescence assay)等,評估機構環境清潔品質,並採用描述性統計及paired t-test做資料分析。結果:本研究共訪問30位機構工作人員,在問卷調查結果中,員工對機構環境整潔的平均滿意度落在3.78~3.98分之間,影響機構環境整潔因素最高分的項目分別為清潔教育訓練(4.0分)、設備清潔容易度(4.0分)、清潔紀錄(3.86分)及清潔工具(3.86分)等。兩機構共同面臨設備老舊、人力不足及資源缺乏的問題,結構性上的阻礙使機構無法符合環境感染管制措施的要求。ATP生物冷光檢測結果顯示手部高接觸的環境表面其受汙染的機會也高,清潔後檢測值(relative light unit, RLU)最高的區域有寢室的床欄(6,412~8,211RLU) 、床旁桌把手(3,134RLU) 、電燈開關(1,827~11,599RLU) 及換藥車把手(8,775RLU),表示機構環境清潔流程有不適當的作業程序,導致清潔後的環境表面汙染更嚴重。
結論:在執行照護工作時,確實的遵從手部衛生及高接觸表面的清潔可有效預防及控制感染事件的發生。針對環境清潔管理,本研究製作了合適長照機構的環境清潔稽核表,期盼未來能運用至其他長照機構,幫助建立稽核制度,促進機構提升環境清潔管理效能。
Purpose: This study investigated a nursing home from the public hospital and a private long-term care facility in Hualien, and evaluated the implementation of environmental infection prevention and control practices, and gave improvement suggestions.
Methods: A case study from March to May in 2020, by using survery, personnel interview, field research and adenosine triphosphate (ATP) bioluminescence assay, to evaluate the quality of environmental cleaning in facilities. The statistical methods were used descriptive statistics and paired-t test for data analysis.
Results: Total 30 of staffs were interviewed, and the result showed that the averages of satisfaction for facillity’s environmental cleanliness were between 3.78 to 3.98 points. The factors which influencing environmental cleanliness were cleaning education and training (4.0 points), equipment cleanliness (4.0 points), cleaning records (3.86 points) and cleaning tools (3.86 points). These two facilities were facing worn-out of equipment, and lack of resources and manpower. Structural barrier restrict the facilities can’t meet the environmental of infection prevention and control practices. The results in ATP bioluminescence assay showed that the high-contact environmental surfaces were most likely to be contaminated. After cleaning procedures, the areas with the highest relative light unit (RLU) were at bed rails (6,412~8,211RLU), handles of bedside table (3,134RLU), light switches (1,827~11,599RLU) in the dormitory and handles of dressing change cart (8,775RLU). The result indicates that the environmental cleaning process had improperated procedures were lead to more surface contamination after cleaning.
Conclusion: The hand hygiene and cleaning of high-contact surfaces are the most important things in facility when staffs doing their care work. In this study, we create an environmental cleaning check list for environmental cleaning management. We hope these check list can be applied to other long-term care facilities; it may help them to establish an audit system and improve the efficiency of environmental cleanliness management.
顯示完整詮釋資料 統計資料

引用此條目

林育楨 (2020). 長照機構環境感染管制實例研究. https://thesis.lib.nycu.edu.tw/handle/20.500.14371/75477

BibTeX RIS

引用文字依 APA 第 7 版格式自動產生,使用前請再核對。

分享

永久網址:https://thesis.lib.nycu.edu.tw/handle/20.500.14371/75477