超空間解析飛秒激發偵測顯微鏡與飛秒瞬態吸收顯微鏡技術研究
顯示簡易詮釋資料 統計資料| 欄位 | 內容 | 語言 |
|---|---|---|
dc.contributor.advisor |
刁維光 | |
dc.contributor.advisor |
Diau, Eric Wei Guang | |
dc.contributor.author |
費愛銘 | |
dc.contributor.author |
Amir Fathi | |
dc.contributor.college |
理學院 | |
dc.contributor.committee |
李遠鵬 | |
dc.contributor.committee |
None | |
dc.contributor.committee |
朱立岡 | |
dc.contributor.committee |
鍾昭宇 | |
dc.contributor.committee |
Lee, Yuan-Pern | |
dc.contributor.committee |
Nobuhiro Ohta | |
dc.contributor.committee |
Chu, Li-Kang | |
dc.contributor.committee |
Chung, Chao-Yu | |
dc.contributor.department |
應用化學系碩博士班 | |
dc.contributor.studentid |
0282516 | |
dc.date.NCLavailable |
2022/08/06 | |
dc.date.USTavailable |
2022/08/06 | |
dc.date.issued |
2020 | |
dc.date.issuedROC |
109 | |
dc.date.paperavailable |
立即公開 | |
dc.date.schoolyear |
108 | |
dc.description.abstract |
想要突破以飛秒雷射為光源之瞬時吸收顯微術的光學解析度上的限制, 過程中必定會面臨許多的挑戰和困難。而本論文將會詳述我們所面臨到的挑戰, 以及如何突破光學限制的方法和巧思來完成此一新型態顯微術。 此一新想法有別於一般的瞬時吸收顯微術之處在於我們使用了三道超快雷射光源。 第一道為雷射模態為TEM00之激發雷射,第二道為雷射模態為TEM01*的激發光源, 其相位與第一道雷射模態為TEM00之激發雷射的相位相差180度, 而第三道光源為雷射模態為TEM00之探測光源。我們將三道雷射光在時間及空間上重合後, 藉由偵測第三道探測光源受到激發光源影響後之探測光源強度的變化情形。 而我們利用此一新型顯微術可以觀測到光學解析度為36 nm之ZnO奈米粒子, 突破了繞射極限的限制(<100 nm)。 我們將此新型顯微術將應用在研究MAPbI3 中的超快電荷動力學上, 並探討目前仍具爭議的晶界與晶粒內部在電荷萃取中所扮演的角色。 為此,我們利用此瞬態吸收顯微鏡(TAM)研究在MAPbI3樣品中的不同地方觀察電荷傳遞隨時間的變化情形。 這裡的主要挑戰是,這種雷射掃描系統相較於掃描式電子顯微鏡(SEM)來說, 其光學解析度非常差,並且不能從光學圖像本身推斷出晶粒尺寸或形態。 而掃描式電子顯微鏡具有極佳的光學解析度,但無法做大範圍的掃描。因此, 如果可以同時重疊兩個影像,則在某些區域的形態和動力學之間的相關性就能被分析。 在這個系統中,我們使用高強度雷射,在膜上蝕刻了一些標記, 以用作TAM和SEM圖像的對齊的標準。最後,我們發現在晶界處的鬆弛現象較慢, 這可以相對應在晶粒邊緣處有較高的捕陷濃度。據推測,晶界充當電荷蓄積中心, 這可能降低電荷萃取效率。 | |
dc.description.abstract |
This dissertation was aimed to bring a brief introduction in various microscopy routine and provide a practical pathway to setup a highly modular and multi-purpose microscope. Building a pump-probe microscope based on a femtosecond laser source cannot be achieved in high sensitivity without facing multiple challenges and difficulties. Here, the effort has been put to address the challenges, difficulties and guidelines and provide solution, workarounds and practical information for a complete setup. After setting up a microscope, we improve the setup by bringing something new to the field in terms of enhancing the resolving power. In the first attempt, the layout was set up to enhance the optical resolution and be able to visualized nanoparticles below the diffraction limit. The main idea was to find a work around that can offer fast acquisition speed and higher resolving power when it comes to nanoparticles place close to each other within the point spread function of a confocal microscope. It was shown that by means of the second pump beam in TEM01* at an anti-phase channel the ZnO nanoparticles in order of 36 nm can be visualized well below the diffraction limit (<100). For another application, the main goal was to develop a system to study the charge dynamics in MAPbI3 spatially and elaborate on the ongoing debate of grain boundary versus the grain interior role in charge extraction. To do so, the system was developed for a transient absorption microscopy (TAM) to observe the temporal profile spatially. The challenge here is, the resolution of such a laser scanning system is very poor and from the optical image itself, one cannot infer the grain size or morphology. However, scanning electron microscope (SEM) is the right tool for imaging thin film with nm resolution. Consequently, if one can overlay both images, the correlation between the morphology and the dynamics for certain region is made possible. In this system, with high intensity laser some markings were etched on the film to be used as an alignment guideline for TAM and SEM images. By mapping the TAM and SEM images of high efficiency MAPbI3 film, it was found that relaxation at the boundaries are slower which corresponds to higher trap state densities at the grain edges. The results show that, the grain boundaries act as charge retards the recombination which might have a positive impact in charge extraction mechanism in contact with a hole or electron transfer layer. | |
dc.description.abstractopendate |
||
dc.description.degree |
博士 | |
dc.description.tableofcontents |
摘要 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iAbstract. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iiiAcknowledgement . . . . . . . . . . . . . . . . . . . . vTable of Contents . . . . . . . . . . . . . . . . . . . . . . . . . . viList of Figures . . . . . . . . . . . . . . . . . . . . . . . . . . . ixList of Tables. . . . . . . . . . . . . . . . . . . . . . . . . . . . xviiAcronyms. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xviiiI Introduction to Various Microscopy Techniquesand Applications . . . 11.1 Brief Introduction of Pump-Probe Microscope techniques . . . . . . 21.1.1 Multi-photon Microscopy . . . . . . . . . . . . . . . . . . . . 21.1.2 Self-phase Modulation . . . . . . . . . . . . . . . . . . . . . 21.1.3 Second and Third Harmonics Generation Microscopy . . . . . . . . 31.1.4 Coherent Anti-stoke Raman Scattering andStimulated Raman Scattering Microscopy. . . . . . . . . . . . . 31.1.5 Transient Absorption Microscopy . . . . . . . . . . . . . . . . 41.2 Respective on this Dissertation. . . . . . . . . . . . . . . . . . 4II Hardware and Software setup . . . . . . . . . . . . . . . . . . . 52.1 Experimental Setup. . . . . . . . . . . . . . . . . . . . . . . . 52.2 Detailed Alignment Procedures . . . . . . . . . . . . . . . . . 122.2.1 AOM Alignment and Optimization . . . . . . . . . . . . . . . . 122.2.2 DC Level Shifter and Synchronous Phase Control . . . . . . . . 182.2.3 Donut Mode generation and optimization . . . . . . . . . . . . 212.2.4 Telescope Alignment and Spatial Filter. . . . . . . . . . . . 272.2.5 Polarization Contrast Measurement and Correction . . . . . . . 302.2.6 Laser Sources . . . . . . . . . . . . . . . . . . . . . . . . 342.2.7 Galvo-Scanners vs Other Types of Scanners . . . . . . . . . . 352.3 Detection Scheme and Image Acquisition . . . . . . . . . . . . . 362.3.1 Detector Selection Guide. . . . . . . . . . . . . . . . . . . 372.3.2 Heterodyne and Homodyne detection scheme . . . . . . . . . . . 392.4 Pump-Probe Microscope Graphical User Interface . . . . . . . . . 41III Label-free Optical Microscope based on a Phase-modulatedFemtosecond Pump-probe Approach with Sub-diffractionResolution [37] . . . . . . . . . . . . . . . . . . . . . . . . 443.1 Introduction and Background . . . . . . . . . . . . . . . . . . 443.2 Experimental setup of the PM-FPPM. . . . . . . . . . . . . . . 533.3 Engineered Point Spread Function (ePSF) . . . . . . . . . . . . 543.4 Resolution Enhancement Demonstration on ZnO nanoparticles . . . 573.5 Potential application of PM-FPPM . . . . . . . . . . . . . . . . 603.6 Advantages and Limitations . . . . . . . . . . . . . . . . . . . 623.7 Future work for the Super-Resolution Project . . . . . . . . . . 643.7.1 Post-Processed Resolution Enhancement Through Phasor Approach . 64IV A Direct Mapping Approach to Understand CarrierRelaxation Dynamics in Varied Regions of aPolycrystalline Perovskite Film [14] . . . . . . . . . . . . . . . 694.1 Background and Introduction . . . . . . . . . . . . . . . . . . . 704.2 Experimental setup and Imaging Routine toMap TAM with SEM images . . . . . . . . . . . . . . . . . . . . . 734.3 Mapping and Analysis of Overlaid TAMand SEM images for MAPbI3 Film . . . . . . . . . . . . . . . . . . 824.4 Advantages and Limitations . . . . . . . . . . . . . . . . . . . . 914.5 Future works . . . . . . . . . . . . . . . . . . . . . . . . . . . 934.5.1 Dynamics at the presence of SnO2 as electron trans fer layer . . 944.5.2 Mapping of Power Dependence Images . . . . . . . . . . . . . . . 954.6 Imaging the Above and Below Band Gap States . . . . . . . . . . . . 97V Summary and conclusion . . . . . . . . . . . . . . . . . . . . . . . 99Bibliography . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 104Appendices. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 123Appendix I Tunable Amplifier . . . . . . . . . . . . . . . . . . . . . 123 | |
dc.identifier.citation |
[1] Maiman, T. H. “Stimulated Optical Radiation in Ruby”. Nature,187, pp. 493–494, aug 1960.[2] Pawley, J. B. (Editor). Handbook Of Biological Confocal Microscopy.Springer US, 2006.[3] Nichols, A. J. and Evans, C. L. “Video-rate Scanning Confocal Mi-croscopy and Microendoscopy”. Journal of Visualized Experiments,oct 2011.[4] Amos, W. B., White, J. G. and Fordham, M. “Use of confocal imag-ing in the study of biological structures”. Applied Optics, 26, p. 3239,aug 1987.[5] Denk, W., Strickler, J. and Webb, W. “Two-photon laser scanningfluorescence microscopy”. Science, 248, pp. 73–76, apr 1990.[6] Robles, F. E., Fischer, M. C. and Warren, W. S. “Femtosecond pulseshaping enables detection of optical Kerr-effect (OKE) dynamics formolecular imaging”. Optics Letters, 39, p. 4788, aug 2014.[7] Fischer, M. C., Wilson, J. W., Robles, F. E. and Warren, W. S. “In-vited Review Article: Pump-probe microscopy”. Review of ScientificInstruments, 87, p. 031101, mar 2016.[8] Squier, J. A., M¨uller, M., Brakenhoff, G. J. and Wilson, K. R. “Thirdharmonic generation microscopy”.Optics Express, 3, p. 315, oct1998.[9] Nucciotti, V., Stringari, C., Sacconi, L., Vanzi, F., Fusi, L., Linari,M., Piazzesi, G., Lombardi, V. and Pavone, F. S. “Probing myosinstructural conformation in vivo by second-harmonic generation mi-croscopy”. Proceedings of the National Academy of Sciences, 107,pp. 7763–7768, apr 2010.[10] Mahou, P., Olivier, N., Labroille, G., Duloquin, L., Sintes, J.-M.,Peyri´eras, N., Legouis, R., D´ebarre, D. and Beaurepaire, E. “Com-bined third-harmonic generation and four-wave mixing microscopyof tissues and embryos”. Biomedical Optics Express, 2, p. 2837, sep2011.[11] Hanninen, A., Shu, M. W. and Potma, E. O.“Hyperspectralimaging with laser-scanning sum-frequency generation microscopy”.Biomedical Optics Express, 8, p. 4230, aug 2017.[12] Zhang, C., Zhang, D. and Cheng, J.-X. “Coherent Raman ScatteringMicroscopy in Biology and Medicine”. Annual Review of BiomedicalEngineering, 17, pp. 415–445, dec 2015.[13] Cheng, J.-X. and Xie, X. S. “Coherent Anti-Stokes Raman Scatter-ing Microscopy:Instrumentation, Theory, and Applications”. TheJournal of Physical Chemistry B, 108, pp. 827–840, jan 2004.[14] Fathi, A., Jokar, E., Lee, Y.-P. and Diau, E. W.-G. “A Direct Map-ping Approach to Understand Carrier Relaxation Dynamics in VariedRegions of a Polycrystalline Perovskite Film”. Angewandte ChemieInternational Edition, jul 2020.[15] Chong, S., Min, W. and Xie, X. S. “Ground-State Depletion Mi-croscopy: Detection Sensitivity of Single-Molecule Optical Absorp-tion at Room Temperature”.The Journal of Physical ChemistryLetters, 1, pp. 3316–3322, nov 2010.[16] Davydova, D., de la Cadena, A., Akimov, D. and Dietzek, B. “Tran-sient absorption microscopy: advances in chemical imaging of pho-toinduced dynamics”. Laser & Photonics Reviews, 10, pp. 62–81, dec2015.[17] Squier, J. and M¨uller, M. “High resolution nonlinear microscopy:A review of sources and methods for achieving optimal imaging”.Review of Scientific Instruments, 72, pp. 2855–2867, jul 2001.[18] Entenberg, D., Wyckoff, J., Gligorijevic, B., Roussos, E. T.,Verkhusha, V. V., Pollard, J. W. and Condeelis, J. “Setup and use ofa two-laser multiphoton microscope for multichannel intravital fluo-rescence imaging”. Nature Protocols, 6, pp. 1500–1520, sep 2011.[19] “Thorlabs (Hallow Retroreflector) ”. “https://www.thorlabs.com/”.[20] “RP-Photonics (Retroreflector)”. “https://www.rp-photonics.com”.[21] “GandH (AOM)”. “https://gandh.com/product-categories/acousto-optic-modulators”.[22] “Thorlabs Vortex Phase Plate”. “https://www.thorlabs.com/”.[23] Galiani, S., Harke, B., Vicidomini, G., Lignani, G., Benfenati, F., Di-aspro, A. and Bianchini, P. “Strategies to maximize the performanceof a STED microscope”. Optics Express, 20, p. 7362, mar 2012.[24] “RPC (VPP1)”. “https://www.rpcphotonics.com/product/vpp-1a”.[25] “SVI (Aperture Overfill)”. “https://svi.nl/ExcitationFillFactor”.[26] “EdmundOptics(BeamExpander)”.“https://www.edmundoptics.com/knowledge-center/application-notes/”.[27] “Thorlabs (Pinhole)”. “https://www.thorlabs.com/newgrouppage9.cfm?objectgroup id=13052”.[28] “Thorlabs(FilmPolarizer)”.“https://www.thorlabs.com/newgrouppage9.cfm?objectgroup_id=4984”.[29] “Thorlabs (PBS)”. “https://www.thorlabs.com/newgrouppage9.cfm?objectgroup_id=739”.[30] “Thorlabs (GT)”.“https://www.thorlabs.com/newgrouppage9.cfm?objectgroup_id=816”.[31] Freudiger, C. W., Yang, W., Holtom, G. R., Peyghambarian, N., Xie,X. S. and Kieu, K. Q. “Stimulated Raman scattering microscopy witha robust fibre laser source”. Nature Photonics, 8, pp. 153–159, jan2014.[32] Gong, L., Wang, Y., Yang, Y., Li, X. and Chen, P. “Mode-lockedfemtosecond laser with a rotary Nd:glass disk”. Applied Optics, 58,p. 6618, aug 2019.[33] “Leica (Resonant Scanner)”. “https://www.leica-microsystems.com/science-lab/what-is-a-resonant-scanner/”.[34] “The WITS$ Guide to Selecting a Photodetector”.“https://hub.hamamatsu.com/jp/en/technical-note/WITS-guide-detector-selection/index.html”.[35] Zhang, D., Slipchenko, M. N., Leaird, D. E., Weiner, A. M. andCheng, J.-X. “Spectrally modulated stimulated Raman scatteringimaging with an angle-to-wavelength pulse shaper”. Optics Express,21, p. 13864, may 2013.[36] Cheng, J.-X. and Xie, X. S. (Editors). Coherent Raman ScatteringMicroscopy. CRC Press, apr 2016.[37] Fathi, A., Chung, C.-Y., Lee, Y.-P. and Diau, E. W.-G.“Label-Free Optical Microscope Based on a Phase-Modulated Femtosec-ond Pump–Probe Approach with Subdiffraction Resolution”. ACSPhotonics, 7, pp. 607–613, mar 2020.[38] Renz, M. “Fluorescence microscopy-A historical and technical per-spective”. Cytometry Part A, 83, pp. 767–779, apr 2013.[39] Abbe, E. “Beitr¨age z¨ur Theorie des Mikroskops und der mikroskopis-chen Wahrnehmung”. Archiv f¨ur Mikroskopische Anatomie, 9, pp.413–468, dec 1873.[40] Rust, M. J., Bates, M., Zhuang, X. and Michael J. Rust Mark Bates,X. Z. “Sub-diffraction-limit imaging by stochastic optical reconstruc-tion microscopy (STORM)”. Nature Methods, 3, pp. 793–796, oct2006.[41] Richardson, W. H.“Bayesian-Based Iterative Method of ImageRestoration”. Journal of the Optical Society of America, 62, p. 55,jan 1972.[42] Hell, S. W. and Wichmann, J. “Breaking the diffraction resolutionlimit by stimulated emission: stimulated-emission-depletion fluores-cence microscopy”. Optics Letters, 19, p. 780, jun 1994.[43] Klar, T. A., Jakobs, S., Dyba, M., Egner, A. and Hell, S. W. “Fluores-cence microscopy with diffraction resolution barrier broken by stim-ulated emission”. Proceedings of the National Academy of Sciences,97, pp. 8206–8210, jul 2000.[44] Kim, H., Bryant, G. W. and Stranick, S. J. “Superresolution four-wave mixing microscopy”. Optics Express, 20, p. 6042, feb 2012.[45] Liu, N., Kumbham, M., Pita, I., Guo, Y., Bianchini, P., Diaspro, A.,Tofail, S. A. M., Peremans, A. and Silien, C. “Far-Field Subdiffrac-tion Imaging of Semiconductors Using Nonlinear Transient Absorp-tion Differential Microscopy”. ACS Photonics, 3, pp. 478–485, feb2016.[46] Huang, B., Bates, M. and Zhuang, X. “Super-Resolution Fluores-cence Microscopy”. Annual Review of Biochemistry, 78, pp. 993–1016, jun 2009.[47] Huang, B., Babcock, H. and Zhuang, X. “Breaking the DiffractionBarrier: Super-Resolution Imaging of Cells”. Cell, 143, pp. 1047–1058, dec 2010.[48] Ash, E. A. and Nicholls, G. “Super-resolution Aperture ScanningMicroscope”. Nature, 237, pp. 510–512, jun 1972.[49] Pohl, D. W., Denk, W. and Lanz, M. “Optical stethoscopy: Imagerecording with resolution λ/20”. Applied Physics Letters, 44, pp.651–653, apr 1984.[50] D¨urig, U., Pohl, D. W. and Rohner, F. “Near-field optical-scanningmicroscopy”. Journal of Applied Physics, 59, pp. 3318–3327, may1986.[51] Betzig, E., Lewis, A., Harootunian, A., Isaacson, M. and Kratschmer,E. “Near Field Scanning Optical Microscopy (NSOM)”. BiophysicalJournal, 49, pp. 269–279, jan 1986.[52] Lewis, A., Isaacson, M., Harootunian, A. and Muray, A. “Develop-ment of a 500 ˚Aspatial resolution ight microscope”. Ultramicroscopy,13, pp. 227–231, jan 1984.[53] Betzig, E., Trautman, J. K., Harris, T. D., Weiner, J. S. and Koste-lak, R. L. “Breaking the Diffraction Barrier: Optical Microscopy ona Nanometric Scale”. Science, 251, pp. 1468–1470, mar 1991.[54] Hell, S. and Stelzer, E. H. K. “Fundamental improvement of reso-lution with a 4Pi-confocal fluorescence microscope using two-photonexcitation”. Optics Communications, 93, pp. 277–282, oct 1992.[55] Hell, S. W. “Far-Field Optical Nanoscopy”. Science, 316, pp. 1153–1158, may 2007.[56] Hell, S. W. and Kroug, M. “Ground-state-depletion fluorscence mi-croscopy: A concept for breaking the diffraction resolution limit”.Applied Physics B Lasers and Optics, 60, pp. 495–497, may 1995.[57] Bretschneider, S., Eggeling, C. and Hell, S. W.“Breaking theDiffraction Barrier in Fluorescence Microscopy by Optical Shelving”.Physical Review Letters, 98, may 2007.[58] Rittweger, E., Wildanger, D. and Hell, S. W. “Far-field fluorescencenanoscopy of diamond color centers by ground state depletion”. EPL(Europhysics Letters), 86, p. 14001, apr 2009.[59] Hofmann, M., Eggeling, C., Jakobs, S. and Hell, S. W. “Breaking thediffraction barrier in fluorescence microscopy at low light intensitiesby using reversibly photoswitchable proteins”. Proceedings of theNational Academy of Sciences, 102, pp. 17565–17569, nov 2005.[60] Gustafsson, M. G. L. “Surpassing the lateral resolution limit by afactor of two using structured illumination microscopy”. Journal ofMicroscopy, 198, pp. 82–87, may 2000.[61] Heintzmann, R. and Cremer, C. G. “Laterally modulated excitationmicroscopy: improvement of resolution by using a diffraction grat-ing”. In I. J. Bigio, H. Schneckenburger, J. Slavik, K. Svanberg andP. M. Viallet (Editors), Optical Biopsies and Microscopic TechniquesIII. SPIE, jan 1999.[62] Betzig, E., Patterson, G. H., Sougrat, R., Lindwasser, O. W.,Olenych, S., Bonifacino, J. S., Davidson, M. W., Lippincott-Schwartz, J. and Hess, H. F.“Imaging Intracellular FluorescentProteins at Nanometer Resolution”.Science, 313, pp. 1642–1645,sep 2006.[63] Chu, S.-W., Su, T.-Y., Oketani, R., Huang, Y.-T., Wu, H.-Y., Yone-maru, Y., Yamanaka, M., Lee, H., Zhuo, G.-Y., Lee, M.-Y., Kawata,S. and Fujita, K. “Measurement of a Saturated Emission of Opti-cal Radiation from Gold Nanoparticles: Application to an UltrahighResolution Microscope”. Physical Review Letters, 112, p. 017402,jan 2014.[64] Lee, H., Oketani, R., Huang, Y.-T., Li, K.-Y., Yonemaru, Y., Ya-manaka, M., Kawata, S., Fujita, K. and Chu, S.-W. “Point spreadfunction analysis with saturable and reverse saturable scattering”.Optics Express, 22, p. 26016, oct 2014.[65] Wang, P., Slipchenko, M. N., Mitchell, J., Yang, C., Potma, E. O.,Xu, X. and Cheng, J.-X. “Far-field imaging of non-fluorescent specieswith subdiffraction resolution”. Nature Photonics, 7, pp. 449–453,jun 2013.[66] Freudiger, C. W., Min, W., Saar, B. G., Lu, S., Holtom, G. R., He,C., Tsai, J. C., Kang, J. X. and Xie, X. S. “Label-Free Biomedi-cal Imaging with High Sensitivity by Stimulated Raman ScatteringMicroscopy”. Science, 322, pp. 1857–1861, dec 2008.[67] Zumbusch, A., Holtom, G. R. and Xie, X. S. “Three-DimensionalVibrational Imaging by Coherent Anti-Stokes Raman Scattering”.Physical Review Letters, 82, pp. 4142–4145, may 1999.[68] Duncan, M. D., Reintjes, J. and Manuccia, T. J. “Scanning coherentanti-Stokes Raman microscope”. Optics Letters, 7, p. 350, aug 1982.[69] Chen, X., Nadiarynkh, O., Plotnikov, S. and Campagnola, P. J. “Sec-ond harmonic generation microscopy for quantitative analysis of col-lagen fibrillar structure”.Nature Protocols, 7, pp. 654–669, mar2012.[70] D´ebarre, D., Supatto, W., Pena, A.-M., Fabre, A., Tordjmann, T.,Combettes, L., Schanne-Klein, M.-C. and Beaurepaire, E. “Imag-ing lipid bodies in cells and tissues using third-harmonic generationmicroscopy”. Nature Methods, 3, pp. 47–53, dec 2005.[71] Grancini, G., Polli, D., Fazzi, D., Cabanillas-Gonzalez, J., Cerullo,G. and Lanzani, G. “Transient Absorption Imaging of P3HT:PCBMPhotovoltaic Blend: Evidence For Interfacial Charge Transfer State”.The Journal of Physical Chemistry Letters, 2, pp. 1099–1105, apr2011.[72] Beeker, W. P., Groß, P., Lee, C. J., Cleff, C., Offerhaus, H. L., Fall-nich, C., Herek, J. L. and Boller, K.-J. “A route to sub-diffractionlimited CARS microscopy”. Optics Express, 17, p. 22632, November2009.[73] Beeker, W. P., Lee, C. J., Boller, K.-J., Groß, P., Cleff, C., Fallnich,C., Offerhaus, H. L. and Herek, J. L.“Spatially dependent Rabioscillations: An approach to sub-diffraction-limited coherent anti-Stokes Raman-scattering microscopy”. Physical Review A, 81, jan2010.[74] Raghunathan, V. and Potma, E. O. “Multiplicative and subtractivefocal volume engineering in coherent Raman microscopy”. Journal ofthe Optical Society of America A, 27, p. 2365, oct 2010.[75] Selmke, M., Braun, M. and Cichos, F. “Photothermal Single-ParticleMicroscopy: Detection of a Nanolens”. ACS Nano, 6, pp. 2741–2749,feb 2012.[76] Devadas, M. S., Devkota, T., Johns, P., Li, Z., Lo, S. S., Yu, K.,Huang, L. and Hartland, G. V. “Imaging nano-objects by linear andnonlinear optical absorption microscopies”. Nanotechnology, 26, p.354001, aug 2015.[77] Ramalingam,V.,Revathidevi,S.,Shanmuganayagam,T. S.,Muthulakshmi, L. and Rajaram, R.“Gold nanoparticle inducesmitochondria-mediated apoptosis and cell cycle arrest in nonsmallcell lung cancer cells”. Gold Bulletin, 50, pp. 177–189, apr 2017.[78] Ghosh, P., Han, G., De, M., Kim, C. K. and Rotello, V. M. “Goldnanoparticles in delivery applications”.Advanced Drug DeliveryReviews, 60, pp. 1307–1315, aug 2008.[79] Peer, D., Karp, J. M., Hong, S., Farokhzad, O. C., Margalit, R.and Langer, R. “Nanocarriers as an emerging platform for cancertherapy”. Nature Nanotechnology, 2, pp. 751–760, dec 2007.[80] Chithrani, D. B. “Intracellular uptake, transport, and processing ofgold nanostructures”. Molecular Membrane Biology, 27, pp. 299–311,oct 2010.[81] Sathuluri, R. R., Yoshikawa, H., Shimizu, E., Saito, M. and Tamiya,E. “Gold Nanoparticle-Based Surface-Enhanced Raman Scatteringfor Noninvasive Molecular Probing of Embryonic Stem Cell Differen-tiation”. PLoS ONE, 6, p. e22802, aug 2011.[82] Kneipp, J., Kneipp, H., McLaughlin, M., Brown, D. and Kneipp,K. “In Vivo Molecular Probing of Cellular Compartments with GoldNanoparticles and Nanoaggregates”. Nano Letters, 6, pp. 2225–2231,oct 2006.[83] Kim, T.-H., Lee, K.-B. and Choi, J.-W.“3D graphene oxide-encapsulated gold nanoparticles to detect neural stem cell differenti-ation”. Biomaterials, 34, pp. 8660–8670, nov 2013.[84] Huang, B., Yan, S., Xiao, L., Ji, R., Yang, L., Miao, A.-J. and Wang,P. “Label-Free Imaging of Nanoparticle Uptake Competition in SingleCells by Hyperspectral Stimulated Raman Scattering”. Small, 14, p.1703246, dec 2017.[85] Navas-Moreno, M., Mehrpouyan, M., Chernenko, T., Candas, D.,Fan, M., Li, J. J., Yan, M. and Chan, J. W. “Nanoparticles for livecell microscopy: A surface-enhanced Raman scattering perspective”.Scientific Reports, 7, jun 2017.[86] Zhang, D., Wang, P., Slipchenko, M. N., Ben-Amotz, D., Weiner,A. M. and Cheng, J.-X. “Quantitative vibrational imaging by hyper-spectral stimulated Raman scattering microscopy and multivariatecurve resolution analysis.”Analytical Chemistry, 85, pp. 98–106,2013.[87] Fereidouni, F., Bader, A. N. and Gerritsen, H. C. “Spectral phasoranalysis allows rapid and reliable unmixing of fluorescence microscopyspectral images”. Optics Express, 20, p. 12729, 2012.[88] Fereidouni, F., Reitsma, K. and Gerritsen, H. C. “High speed mul-tispectral fluorescence lifetime imaging.”Optics express, 21, pp.11769–11782, 2013.[89] Fereidouni, F., Blab, G. a. and Gerritsen, H. C. “Phasor based analy-sis of FRET images recorded using spectrally resolved lifetime imag-ing”. Methods and Applications in Fluorescence, 2, p. 35001, may2014.[90] Fu, D. and Xie, X. S. “Reliable cell segmentation based on spec-tral phasor analysis of hyperspectral stimulated Raman scatteringimaging data.” Analytical chemistry, 86, pp. 4115–4119, 2014.[91] Lanzan`o, L., Coto Hern´andez, I., Castello, M., Gratton, E., Diaspro,A. and Vicidomini, G. “Encoding and decoding spatio-temporal in-formation for super-resolution microscopy”. Nature Communications,6, p. 6701, 2015.[92] Digman, M. A., Caiolfa, V. R., Zamai, M. and Gratton, E.“The Phasor Approach to Fluorescence Lifetime Imaging Analysis”.Biophysical Journal, 94, pp. L14–L16, jan 2008.[93] Fereidouni, F., Esposito, a., Blab, G. a. and Gerritsen, H. C. “A mod-ified phasor approach for analyzing time-gated fluorescence lifetimeimages”. Journal of Microscopy, 244, pp. 248–258, 2011.[94] Robles, F. E., Wilson, J. W., Fischer, M. C. and Warren, W. S.“Adapting phasor analysis for nonlinear pump-probe microscopy”.Optics Express, 20, p. 17082, June 2013.[95] Robles, F. E., Wilson, J. W., Fischer, M. C. and Warren, W. S. “Pha-sor analysis for nonlinear pump-probe microscopy”. Optics Express,20, p. 17082, jul 2012.[96] Kim, H.-S., Lee, C.-R., Im, J.-H., Lee, K.-B., Moehl, T., Marchioro,A., Moon, S.-J., Humphry-Baker, R., Yum, J.-H., Moser, J. E.,Gr¨atzel, M. and Park, N.-G.“Lead Iodide Perovskite SensitizedAll-Solid-State Submicron Thin Film Mesoscopic Solar Cell with Ef-ficiency Exceeding 9%”. Scientific Reports, 2, aug 2012.[97] Lee, M. M., Teuscher, J., Miyasaka, T., Murakami, T. N. and Snaith,H. J. “Efficient Hybrid Solar Cells Based on Meso-SuperstructuredOrganometal Halide Perovskites”.Science, 338, pp. 643–647, oct2012.[98] Yang, D., Sano, T., Yaguchi, Y., Sun, H., Sasabe, H. and Kido,J.“Achieving 20% Efficiency for Low-Temperature-Processed In-verted Perovskite Solar Cells”. Advanced Functional Materials, 29,p. 1807556, dec 2018.[99] Matsui, T., Yamamoto, T., Nishihara, T., Morisawa, R., Yokoyama,T., Sekiguchi, T. and Negami, T. “Compositional Engineering forThermally Stable, Highly Efficient Perovskite Solar Cells Exceeding20% Power Conversion Efficiency with 85 °C/85% 1000 h Stability”.Advanced Materials, 31, p. 1806823, jan 2019.[100] Park, B.-w., Kedem, N., Kulbak, M., Lee, D. Y., Yang, W. S., Jeon,N. J., Seo, J., Kim, G., Kim, K. J., Shin, T. J., Hodes, G., Ca-hen, D. and Seok, S. I. “Understanding how excess lead iodide pre-cursor improves halide perovskite solar cell performance”. NatureCommunications, 9, aug 2018.[101] Tsai, H., Asadpour, R., Blancon, J.-C., Stoumpos, C. C., Durand, O.,Strzalka, J. W., Chen, B., Verduzco, R., Ajayan, P. M., Tretiak, S.,Even, J., Alam, M. A., Kanatzidis, M. G., Nie, W. and Mohite, A. D.“Light-induced lattice expansion leads to high-efficiency perovskitesolar cells”. Science, 360, pp. 67–70, apr 2018.[102] Lin, K., Xing, J., Quan, L. N., de Arquer, F. P. G., Gong, X., Lu,J., Xie, L., Zhao, W., Zhang, D., Yan, C., Li, W., Liu, X., Lu, Y.,Kirman, J., Sargent, E. H., Xiong, Q. and Wei, Z. “Perovskite light-emitting diodes with external quantum efficiency exceeding 20 percent”. Nature, 562, pp. 245–248, oct 2018.[103] Zhao, L., Lee, K. M., Roh, K., Khan, S. U. Z. and Rand, B. P.“Improved Outcoupling Efficiency and Stability of Perovskite Light-Emitting Diodes using Thin Emitting Layers”. Advanced Materials,31, p. 1805836, nov 2018.[104] Mikosch, A., Ciftci, S., Tainter, G., Shivanna, R., Haehnle, B., De-schler, F. and Kuehne, A. J. C. “Laser Emission from Self-AssembledColloidal Crystals of Conjugated Polymer Particles in a Metal-HalidePerovskite Matrix”. Chemistry of Materials, 31, pp. 2590–2596, mar2019.[105] Liu, Z., Hu, Z., Shi, T., Zhang, Z., Xing, X., Tang, X., Du, J. andLeng, Y. “Tunable Amplified Spontaneous Emission and Lasing fromAll-inorganic Perovskite Nanocube”. In CLEO Pacific Rim Confer-ence. OSA, 2018.[106] Yan, K., Peng, M., Yu, X., Cai, X., Chen, S., Hu, H., Chen, B., Gao,X., Dong, B. and Zou, D. “High-performance perovskite memris-tor based on methyl ammonium lead halides”. Journal of MaterialsChemistry C, 4, pp. 1375–1381, 2016.[107] Gu, C. and Lee, J.-S. “Flexible Hybrid Organic–Inorganic PerovskiteMemory”. ACS Nano, 10, pp. 5413–5418, apr 2016.[108] Vicente, N. and Garcia-Belmonte, G. “Methylammonium Lead Bro-mide Perovskite Battery Anodes Reversibly Host High Li-Ion Con-centrations”. The Journal of Physical Chemistry Letters, 8, pp. 1371–1374, mar 2017.[109] Ball, J. M. and Petrozza, A.“Defects In Perovskite-halides AndTheir Effects In Solar Cells”. Nature Energy, 1, oct 2016.[110] Chu, Z., Yang, M., Schulz, P., Wu, D., Ma, X., Seifert, E., Sun,L., Li, X., Zhu, K. and Lai, K.“Impact of grain boundaries onefficiency and stability of organic-inorganic trihalide perovskites”.Nature Communications, 8, dec 2017.[111] Kim, H. D. and Ohkita, H. “Charge traps in lead-halide perovskiteswith different grain sizes”. Japanese Journal of Applied Physics, 57,p. 08RE03, jul 2018.[112] Reid, O. G., Yang, M., Kopidakis, N., Zhu, K. and Rumbles, G.“Grain-Size-Limited Mobility in Methylammonium Lead Iodide Per-ovskite Thin Films”. ACS Energy Letters, 1, pp. 561–565, aug 2016.[113] Kim, H. D., Ohkita, H., Benten, H. and Ito, S.“PhotovoltaicPerformance of Perovskite Solar Cells with Different Grain Sizes”.Advanced Materials, 28, pp. 917–922, dec 2015.[114] Ma, Y., Liu, Y., Shin, I., Hwang, I.-W., Jung, Y. K., Jeong, J. H.,Park, S. H. and Kim, K. H. “Understanding and Tailoring GrainGrowth of Lead-Halide Perovskite for Solar Cell Application”. ACSApplied Materials & Interfaces, 9, pp. 33925–33933, sep 2017.[115] Son, D.-Y., Lee, J.-W., Choi, Y. J., Jang, I.-H., Lee, S., Yoo, P. J.,Shin, H., Ahn, N., Choi, M., Kim, D. and Park, N.-G. “Self-formedgrain boundary healing layer for highly efficient CH3NH3PbI3 per-ovskite solar cells”. Nature Energy, 1, jun 2016.[116] Shao, Y., Fang, Y., Li, T., Wang, Q., Dong, Q., Deng, Y., Yuan,Y., Wei, H., Wang, M., Gruverman, A., Shield, J. and Huang,J. “Grain boundary dominated ion migration in polycrystalline or-ganic–inorganic halide perovskite films”. Energy & EnvironmentalScience, 9, pp. 1752–1759, 2016.[117] Gabriel, M. M., Kirschbrown, J. R., Christesen, J. D., Pinion, C. W.,Zigler, D. F., Grumstrup, E. M., Mehl, B. P., Cating, E. E. M.,Cahoon, J. F. and Papanikolas, J. M. “Direct Imaging of Free Carrierand Trap Carrier Motion in Silicon Nanowires by Spatially-SeparatedFemtosecond Pump–Probe Microscopy”. Nano Letters, 13, pp. 1336–1340, feb 2013.[118] Murphy, S. and Huang, L. “Transient absorption microscopy studiesof energy relaxation in graphene oxide thin film”. Journal of Physics:Condensed Matter, 25, p. 144203, mar 2013.[119] Yuan, L., Chung, T.-F., Kuc, A., Wan, Y., Xu, Y., Chen, Y. P.,Heine, T. and Huang, L.“Photocarrier generation from inter-layer charge-transfer transitions in WS 2 -graphene heterostructures”.Science Advances, 4, p. e1700324, feb 2018.[120] Wen, X., Sheng, R., Ho-Baillie, A. W. Y., Benda, A., Woo, S., Ma,Q., Huang, S. and Green, M. A. “Morphology and Carrier Extrac-tion Study of Organic-Inorganic Metal Halide Perovskite by One-and Two-Photon Fluorescence Microscopy”. The Journal of PhysicalChemistry Letters, 5, pp. 3849–3853, 2014.[121] Watson, B. R., Yang, B., Xiao, K., Ma, Y.-Z., Doughty, B. andCalhoun, T. R. “Elucidation of Perovskite Film Micro-OrientationsUsing Two-Photon Total Internal Reflectance Fluorescence Mi-croscopy”. The Journal of Physical Chemistry Letters, 6, pp. 3283–3288, aug 2015.[122] de Quilettes, D. W., Vorpahl, S. M., Stranks, S. D., Nagaoka, H.,Eperon, G. E., Ziffer, M. E., Snaith, H. J. and Ginger, D. S. “Impactof microstructure on local carrier lifetime in perovskite solar cells”.Science, 348, pp. 683–686, may 2015.[123] Simpson, M. J., Doughty, B., Yang, B., Xiao, K. and Ma, Y.-Z.“Spatial Localization of Excitons and Charge Carriers in Hybrid Per-ovskite Thin Films”. The Journal of Physical Chemistry Letters, 6,pp. 3041–3047, aug 2015.[124] Simpson, M. J., Doughty, B., Yang, B., Xiao, K. and Ma, Y.-Z. “Sep-aration of Distinct Photoexcitation Species in Femtosecond TransientAbsorption Microscopy”. ACS Photonics, 3, pp. 434–442, feb 2016.[125] Doughty, B., Simpson, M. J., Yang, B., Xiao, K. and Ma, Y.-Z. “Sim-plification of femtosecond transient absorption microscopy data fromCH3NH3PbI3 perovskite thin films into decay associated amplitudemaps”. Nanotechnology, 27, p. 114002, feb 2016.[126] Snaider, J. M., Guo, Z., Wang, T., Yang, M., Yuan, L., Zhu, K.and Huang, L. “Ultrafast Imaging of Carrier Transport across GrainBoundaries in Hybrid Perovskite Thin Films”. ACS Energy Letters,3, pp. 1402–1408, may 2018.[127] Guo, Z., Manser, J. S., Wan, Y., Kamat, P. V. and Huang, L. “Spatialand temporal imaging of long-range charge transport in perovskitethin films by ultrafast microscopy”. Nature Communications, 6, p.7471, jun 2015.[128] Vru´cini´c, M., Matthiesen, C., Sadhanala, A., Divitini, G., Cacovich,S., Dutton, S. E., Ducati, C., Atat¨ure, M., Snaith, H., Friend, R. H.,Sirringhaus, H. and Deschler, F. “Local Versus Long-Range Diffu-sion Effects of Photoexcited States on Radiative Recombination inOrganic-Inorganic Lead Halide Perovskites”. Advanced Science, 2,p. 1500136, jul 2015.[129] Simpson, M. J., Doughty, B., Yang, B., Xiao, K. and Ma, Y.-Z. “Imaging Electronic Trap States in Perovskite Thin Films withCombined Fluorescence and Femtosecond Transient Absorption Mi-croscopy”. The Journal of Physical Chemistry Letters, 7, pp. 1725–1731, apr 2016.[130] Nah, S., Spokoyny, B., Stoumpos, C., Soe, C. M. M., Kanatzidis, M.and Harel, E. “Spatially segregated free-carrier and exciton popula-tions in individual lead halide perovskite grains”. Nature Photonics,11, pp. 285–288, mar 2017.[131] Nah, S., Spokoyny, B., Jiang, X., Stoumpos, C., Soe, C. M. M.,Kanatzidis, M. G. and Harel, E. “Transient Sub-bandgap States inHalide Perovskite Thin Films”. Nano Letters, 18, pp. 827–831, feb2018.[132] Grancini, G., Viola, D., Gandini, M., Altamura, D., Pogna, E.A. A., D’Innocenzo, V., Bargigia, I., Giannini, C., Cerullo, G.and Petrozza, A. “Lattice Distortions Drive Electron–Hole Correla-tion within Micrometer-Size Lead-Iodide Perovskite Crystals”. ACSEnergy Letters, 2, pp. 265–269, jan 2017.[133] Benetti, D., Jokar, E., Yu, C.-H., Fathi, A., Zhao, H., Vomiero, A.,Diau, E. W.-G. and Rosei, F. “Hole-extraction and photostabilityenhancement in highly efficient inverted perovskite solar cells throughcarbon dot-based hybrid material”. Nano Energy, 62, pp. 781–790,aug 2019.[134] Stranks, S. D., Eperon, G. E., Grancini, G., Menelaou, C., Alco-cer, M. J. P., Leijtens, T., Herz, L. M., Petrozza, A. and Snaith,H. J. “Electron-Hole Diffusion Lengths Exceeding 1 Micrometer inan Organometal Trihalide Perovskite Absorber”. Science, 342, pp.341–344, oct 2013.[135] Yun, J. S., Ho-Baillie, A., Huang, S., Woo, S. H., Heo, Y., Seidel, J.,Huang, F., Cheng, Y.-B. and Green, M. A. “Benefit of Grain Bound-aries in Organic–Inorganic Halide Planar Perovskite Solar Cells”. TheJournal of Physical Chemistry Letters, 6, pp. 875–880, feb 2015.[136] Yang, M., Zeng, Y., Li, Z., Kim, D. H., Jiang, C.-S., van de Lagemaat,J. and Zhu, K. “Do grain boundaries dominate non-radiative recom-bination in CH3NH3PbI3 perovskite thin films?” Physical ChemistryChemical Physics, 19, pp. 5043–5050, 2017.[137] Wang, Y., Fang, W.-H., Long, R. and Prezhdo, O. V. “SymmetryBreaking at MAPbI3 Perovskite Grain Boundaries Suppresses ChargeRecombination: Time-Domain ab Initio Analysis”. The Journal ofPhysical Chemistry Letters, 10, pp. 1617–1623, mar 2019.[138] Jiang, X., Hoffman, J., Stoumpos, C. C., Kanatzidis, M. G. andHarel, E. “Transient Sub-Band-Gap States at Grain Boundaries ofCH3NH3PbI3 Perovskite Act as Fast Temperature Relaxation Cen-ters”. ACS Energy Letters, 4, pp. 1741–1747, jun 2019.[139] Jiang, Q., Zhang, X. and You, J. “SnO2 : A Wonderful ElectronTransport Layer for Perovskite Solar Cells”. Small, 14, p. 1801154,jun 2018.[140] Manser, J. S. and Kamat, P. V. “Band filling with free charge carriersin organometal halide perovskites”. Nature Photonics, 8, pp. 737–743, aug 2014.[141] Savikhin, S.“Shot-noise-limited detection of absorbance changesinduced by subpicojoule laser pulses in optical pump-probe exper-iments”. Review of Scientific Instruments, 66, pp. 4470–4474, sep1995. | |
dc.identifier.uri |
https://hdl.handle.net/20.500.14371/75729 | |
dc.language.iso |
英文 | |
dc.relation.alma |
990057788440206772 | |
dc.relation.page |
125 | |
dc.subject.keyword |
空間解析 | |
dc.subject.keyword |
飛秒激發 | |
dc.subject.keyword |
顯微鏡 | |
dc.subject.keyword |
飛秒瞬態吸收顯微鏡 | |
dc.subject.keyword |
Ultrafast Microscopy | |
dc.subject.keyword |
Super-resolution | |
dc.subject.keyword |
Pump-Probe Microscopy | |
dc.subject.keyword |
Perovskite Photovoltaic | |
dc.subject.keyword |
Transient Absorption Microscopy | |
dc.title |
超空間解析飛秒激發偵測顯微鏡與飛秒瞬態吸收顯微鏡技術研究 | zh-TW |
dc.title |
Ultrafast Pump-Probe Microscope with Super-resolution and Transient Absorption Microscope Image Mapping With SEM | en |
dc.type |
Thesis | zh-TW |
檔案
- 01.pdf (4.10 MB, Adobe PDF)
所屬典藏: 應用化學系
引用此條目
Amir Fathi (2020). Ultrafast Pump-Probe Microscope with Super-resolution and Transient Absorption Microscope Image Mapping With SEM. https://thesis.lib.nycu.edu.tw/handle/20.500.14371/75729
引用文字依 APA 第 7 版格式自動產生,使用前請再核對。
分享
永久網址:https://thesis.lib.nycu.edu.tw/handle/20.500.14371/75729