自古以來,許多科學家致力於發展電化學領域。電化學可以被應用於許多方面,例如常看到的電池、電鍍方法、水質淨化以及感測器的應用,這些與我們生活息息相關的事物,都運用到了電化學原理。在生醫應用上,電化學更是不可或缺的一環,許多非常低濃度的檢測都需要仰賴電化學的高靈敏度才有辦法測試得到。
現今社會由於醫療的進步,人們的壽命越來越長,當然與年紀增長相關的疾病也就不能輕易忽視。根據2019年世界阿茲海默症協會的研究報告指出,超過62%的健康照護者認為失智症為正常老化並非疾病。事實上失智症是一種最常見的神經退化性疾病,而大部分為阿茲海默症患者。照顧阿茲海默症患者不僅僅需要高額的醫療支出,也需要家人精神上的高度付出,這些不但會造成社會的負擔成本上升,同時也有造成家庭失和的可能。如果能在早期就將阿茲海默症患者檢測出來,除了能有效控制病情也能減輕家庭的照護壓力。目前最主要認為造成阿茲海默症的成因為乙型類澱粉蛋白的堆積,並且科學界認為或許透過Aβ40和Aβ42的比例就能預測阿茲海默症的嚴重程度。
在這篇研究當中,我透過收集健康女性的淚液及血液檢體,分析Aβ40以及Aβ42的含量,除了探討比例上的差別,也發現了關於淚液檢體的新突破。為了達到早期診斷以及臨床照護,我也開發了一套可攜式的系統,除了能夠降低測量成本外,也能達到如實驗室儀器的精準程度,這或許是一個將阿茲海默症的居家檢驗實現的方案。
Historically, many scientists strive on electrochemistry field. Electrochemistry can be applied on many fields, like battery, plating, water purification, electric titration, and sensors, etc. For biomedical application, the most important is electrochemistry can assist sensors development, high sensitivity can utilize on low concentration measuring.
Time past and people getting elder and elder. In World Alzheimer report 2019: Attitudes to dementia analyses finding that almost 62% of healthcare providers worldwide think dementia is part of normal aging. In fact, dementia is the most common neurodegenerative disorder, and Alzheimer’s Disease (AD) is the majority. Taking care for AD patient cost a lot, not only medical cost but also family’s effort. If AD patients can be diagnosed in early stage, it can ease the stress from caring. The most general theory of AD pathogen is amyloid cascade. Aβ has occupied a considerable argument in AD pathophysiology, and the ratio of Aβ40 and Aβ42 might predict the severity of AD.
In this research, I will reveal the ratio of Aβ40 and Aβ42 in heathy female, and the breakthrough of new specimen - tears. For the point of care development, I design a portable device to measure the chemical chip of detecting Aβ40 and Aβ42. This portable device is small and have high accuracy as CHI920D do, this might be a milestone for AD point of care revolution.