摘要

隨著科技進步,疾病檢測的方式越來越多元,但檢測場所大多侷限於醫院及實驗室單位。因此,本研究的目標將開發具有低成本、快速、微型化且檢測精準的生物晶片。
本研究基於導模共振原理,開發出週期梯度導模共振(GGP-GMR)生物感測器。首先將會探討生物晶片的光學特性,並經由蔗糖溶液檢測與薄膜沉積實驗測試元件之共振半高寬與靈敏度,並以量化後的結果設計一種新型的微型化陣列式晶片。在蔗糖溶液檢測中,三種厚度分別為130、140和150 nm的GGP-GMR,模擬結果顯示半高寬在週期350 nm至400 nm間的值差異並不明顯,而厚度為130 nm的GGP-GMR,靈敏度大於其他兩者,在半高寬及靈敏度的實驗結果中也顯示了相同的趨勢。在薄膜沉積測試中,模擬與實驗結果的半高寬及靈敏度皆隨著共振波長呈上升趨勢。根據蔗糖溶液檢測與薄膜沉積實驗結果,計算定義為靈敏度與半高寬比值的品質因數(Figure of Merit, FOM),並確定了後續生物分子檢測的最佳入射波長與膜厚。
為了達到多重檢測的目標,本實驗設計一種雙通道微流道與陣列式晶片同時量測白蛋白與肌酸酐。陣列式週期梯度導模共振結構將週期範圍設計為370至390 nm,間隔2 nm,且同一週期重複100次,並選用671 nm (656 nm LED + 671 nm 窄頻帶通濾鏡)的光源做為入射光源。最後,白蛋白與肌酸酐的量測範圍分別為0.8 – 500 µg/ml與1 µg/ml – 10 mg/ml,且其檢測極限分別為17.78µg/ml與22.76µg/ml,成功在新型的陣列式週期梯度導模共振結構搭載雙通道微流道的情況下完成了多重檢測,不僅達成了低成本、微型化的架設系統,更具有快速與檢測精準的特色。
With the advancement of science and technology, there are many disease diagnostic methods, but the testing places are mostly limited to hospitals and laboratory units. Therefore, the goal of this research is to develop low-cost, fast, miniaturized and accurate biochips for potential point of care applications.
Based on the principle of guided-mode resonance, this research develops a gradient grating period guided-mode resonance (GGP-GMR) biosensor. First, the optical characteristics of GGP-GMR will be discussed, and the resonant linewidth and sensitivity will be studied through simulation calculation and experiments. A miniaturized GGP-GMR sensor array will then be designed accordingly.
Through detection of sucrose solutions, GGP-GMR with thicknesses of 130, 140 and 150 nm was investigated. The simulation results show no significant difference in linewidth in the period between 350 and 400 nm. By contrast, the thickness of 130 nm shows higher sensitivity. In the thin film deposition test, both the linewidth and sensitivity increase with wavelength in simulation and experiment. Based on sucrose solution measurement and thin film deposition experiments, figure of merit defined as the ratio of sensitivity to linewidth are calculated and the optimal incident wavelength and film thickness are determined for the subsequent biomolecule detection.
In order to achieve multiple detection, a dual-channel microfluidic channel and GGP-GMR array chip were designed to measure albumin and creatinine simultaneously. The sensor array was designed to have periods ranging from 370 to 390 nm in an increment of 2 nm and a 671 nm (656 nm LED + 671 nm narrowband filter) was used as the incident light source. Finally, the measurement ranges of albumin and creatinine are 0.8 – 500 µg/ml and 1 µg/ml – 10 mg/ml, and their detection limits are 17.78 µg/ml and 22.76 µg/ml, respectively. The proposed GGP-GMR with two-channel microfluidic chip are successfully used to achieve multiple detections simultaneously, which not only achieve a low-cost and miniaturized erection system, but also has the characteristics of rapid and accurate detection.

所屬典藏

機械工程學系
顯示完整詮釋資料 統計資料

引用此條目

楊念祖 (2020). 週期梯度導模共振感測器. https://thesis.lib.nycu.edu.tw/handle/20.500.14371/76144