用於奈米微粒分徑的慣性衝擊器
Inertial impactor as a nanoparticle classifier
摘要
隨著奈米科技的快速發展,奈米粉體被廣泛的應用在醫藥、電子及半導體產業等。然而,由於奈米微粒易受膠結作用的影響,因此市面上並未有合適的奈米微粒分徑器能夠將奈米微粒從粉體中均勻且準確的分離出來。本研究主要目的為開發一個用於奈米微粒分徑的慣性衝擊器 (Nanoparticle Inertial Classifier, NIC),以得到粒徑分佈較狹窄的奈米微粒且可長時間使用而不受微粒負荷的影響。NIC主要由一個多微孔噴孔片 (含163個直徑為70微米的孔洞) 及一個可注水清洗的衝擊板所組成,以潮濕的玻璃纖維濾紙作為衝擊基質,連續注水將累積在衝擊板表面的微粒清洗乾淨以解決為粒過度負荷的問題。由衝擊器校正結果顯示,當S/W (S:噴孔至衝擊板的距離; W:噴孔孔徑) 為5.86時,NIC的截取氣動直徑 (dpa50) 為100.61 nm且收集效率曲線的陡峭度 () 為1.55。當微粒負荷量由0增加至3.533 mg時,NIC的dpa50變化介於100.00至102.20 nm間,顯示該衝擊器無微粒負荷影響。由微粒分徑表現結果可知,當微粒質量濃度 (CM) 為18 mg/m3時,可從數目中位粒徑 (NMD) 為210.48 nm、幾何標準差 (GSD) 為1.91的奈米二氧化鈦粉體中分離出NMD為81.04 nm、GSD為1.57的微粒。由於奈米微粒會受膠結作用影響,因此將SMPS數據換算成微粒質量濃度時需考慮微粒之形狀因子及總體密度,其換算結果與以MOUDI直接量測之結果相符。另外,當CM為18 mg/m3時,NIC連續操作60分鐘後其dpa50不會改變; 當CM增加至4.26 及 16.28 mg/m3時,微粒負荷影響仍不顯著,但是所分離出來的微粒之NMD會增大為121.44及137.19 nm,其原因為奈米微粒之膠結作用在微粒質量濃度較高時影響更甚。該NIC可用來評估勞工在高奈米微粒濃度的作業場所之奈米微粒曝露量,也可將其規模化後用來分離出高濃度的奈米粉體,以得到準確及狹窄之粒徑分佈的微粒。
With the rapid development of nanotechnology around the world, nano-powders are widely used in many industries, including medicine, electronics and semiconductors. However, current available classifiers are hard to achieve the classification of dispersed nano-powders, which are normally in agglomerate forms and larger than 1.0 micrometer in diameter, into the nano-sized range. In this study, a nanoparticle inertial classifier (NIC) is developed to classify dispersed nanopowder with a narrow distribution in nano-sized range. The NIC consists of the micro-orifice plate with 163 nozzles (70 μm in the inner diameter), and the wetted glass fiber filter substrate on which water is injected to wash off the deposited powder continuously to eliminate the particle overloading effect. The cut-size (dpa50) of the NIC is around 100 nm at the S/W ratio (S: jet-to-plate distance; W: nozzle diameter) of 5.86 and the sharpness of 1.55. The results show that the NIC has no particle loading effect with the dpa50 varying from 100.00 to 102.20 nm as the nano-TiO2 loaded mass is increased from 0 to 3.533 mg. The test results show that the NIC achieves a narrow nano-size distribution with number mean diameter (NMD) of 81.04 nm and geometric standard deviation (GSD) of 1.57 after classifying disperse nano-TiO2 powders with the NMD of 210.48 nm and GSD of 1.91 when the particle mass concentration (CM) is 18 mg/m3. The particle mass distribution converted from SMPS is consistent with that measured by MOUDI when taking into account the shape factor and the bulk density of the nano-TiO2 agglomerated particles. Additionally, the dpa50 of the NIC is not shifted when it is operated 60 minutes at the CM of 18 mg/m3 due to the continuously washing. At the higher CM of 4.26 and 16.28 mg/m3, the particle loading effect is still negligible but the NMD of classified particles is increased to larger values of 121.44 and 137.19 nm, respectively, due to particle agglomeration effect during the impaction process. The current NIC can be used for personal nanoparticle sampling at workplaces with high particle concentrations and can be scaled up to classify nanopowders to achieve smaller and narrower distribution without particle loading effect for long-term operation.