環境因子對有機無機複合拓印高分子吸附與固相萃取雙酚A能力之影響
Influences of Environmental Factors on Adsorption and Solid-Phase Extraction Ability of Imprinted Organic-Inorganic Hybrids for Bisphenol A
摘要
本研究使用以雙酚A (bisphenol A, BPA) 作為模板的有機無機複合分子拓印高分子 (molecularly imprinted hybrids, MIH) 作為吸附材料,探討不同的環境因子包括pH值、離子強度及天然有機物質對其吸附能力的影響,並將MIH與固相萃取 (solid phase extraction, SPE) 技術結合,應用於環境水樣中,瞭解MIH萃取BPA的能力。研究結果顯示MIH在20分鐘即可達吸附平衡,最大吸附量為40.4 mg/g,當存有結構類似物雙酚F (2,2’-bisphenol F ,BPF) 及Phenol時,MIH仍對BPA具有選擇及辨識的能力。MIH對BPA的吸附能力在pH 2.0-9.0時不受pH影響,pH大於10.0時,由於解離的BPA分子會與表面電荷為負電的MIH產生靜電排斥力,MIH吸附量由25.2下降至15.2 mg/g;此外鹽析效應使得BPA在3000 mM NaCl存在下吸附量提升1.5倍,而MIH表面的負電性則抑制腐植酸 (humic acid, HA) 對BPA吸附的干擾。最後以MIH作為SPE材料,在高效液相層析儀 (high performance liquid chromatography-photodiode array detectors, HPLC-PDA) 分析BPA方法中,其方法偵測極限 (method detection limit, MDL) 可低至16.77 ng/mL,為商用BPA-MIP SPE與C18 SPE的0.2-0.6倍,且將MIH-SPE應用於環境樣品包含河水、湖水及海水中,回收率皆在80.9-115.5%範圍內,相對標準偏差 (relative standard deviations, RSD%, n=3) 都在7.9%以下,顯示MIH具有高度SPE應用潛力。
In this study, an organic-inorganic molecularly imprinted hybrid (MIH) was synthesized as adsorbent for bisphenol A (BPA) adsorption, and its adsorption ability under different pH, ionic strength, and in the presence of natural organic matters were examined in detail. Moreover, the MIH was used as content for solid phase extraction (SPE) and its extraction ability to recover BPA from field water samples was evaluated. Adsorption results showed that the MIH had a short adsorption equilibrium time of 20 min, maximum adsorption capacity of 40.4 mg/g, and highly selective to BPA in the presence of analogs. The MIH maintained its BPA adsorption ability over pH 2.0-9.0 and decreased from 25.2 to 15.2 mg/g when pH was higher than 10.0 as the consequence of electrostatic repulsion between the negatively charged surface and BPA anions. The adsorption increased by 1.5 times in the presence of NaCl (3000 mM) due to salting-out effect. Moreover, humic acid had little influence on the BPA adsorption because the negatively charged MIH surface suppressed HA adhesion. The detection limit of high performance liquid chromatography-photodiode array detectors (HPLC-PDA) coupled with MIH-SPE for BPA-analysis were 16.77 ng/L, respectively, which were 0.2-0.6 times lower than those with the commercial BPA-MIP SPE and C18 SPE cartridges. In addition, the MIH-SPE exhibited 80.9-115.5% recovery with RSD% value (n=3) below 7.9% for BPA extraction from river water, lake water, and seawater. These results clearly demonstrated that the MIH has high potential for SPE application.