利用動態反應與識別模態建構建築結構勁度矩陣並進行損傷評估
Identification of stiffness matrix of a building via dynamic responses and modal parameters with application to building damage assessment
摘要
本研究利用貝氏機率推導所得結構地震歷時反應之相關目標函數配合模態目標函數,透過布穀鳥演算法與Interior-point演算法尋找造成目標函數極值的參數,進行結構模型更新,估算結構勁度矩陣。再依所得之勁度矩陣建立等價剪力屋架的損傷指標,確認損傷樓層及可能損傷程度。以ETABS商業套裝軟體建構一八層樓鋼構架,進行地震數值模擬反應,其中考慮第一或第三樓層柱的彈性係數有10%或20%的折減;探討10%雜訊及不完全量測反應資料對估算勁度矩陣的影響。結果顯示本研究分析流程能從含雜訊之不完全量測反應準確估算勁度矩陣;所得的等價剪力屋架損傷指標可準確反應損傷樓層,但稍微低估損傷程度。本研究所提之分析方法亦應用於分析國家地震工程研究中心(NCREE)所進行之兩組八層樓鋼構架振動台試驗,其中一組為鋼板柱構架,以一樓板柱切削模擬損傷;另一組則為H型鋼柱構架,改變三樓或六樓柱勁度模擬不同程度的損傷。分析結果顯示,比較損傷前後勁度矩陣的對角線分量,可判斷損傷樓層及概估損傷程度。而等價剪力屋架損傷指標於H型鋼柱構架雖能準確顯示損傷樓層,但嚴重低估損傷程度。
This study proposes a procedure to determine the stiffness matrix and modal damping ratios of a building from its dynamic responses under an earthquake. The procedure combines a time-domain objective function based on the dynamic responses of a building with contains based on modal parameters and a modal domain objective function based on its identified modal parameters. The Cuckoo search algorithm and the interior-point algorithm are employed to find the stiffness components and damping ratios minimizing the objective functions. The proposed constrains significantly save the computational cost, and the modal domain objective function is active when the stiffness components in the Cuckoo search process do not give the modal parameters satisfying the constrains. Based on the obtained stiffness matrix, a modified damage index for a shear building is applied to locate the damaged stories and estimate the severity of the damage. The validity of the proposed procedure is confirmed by processing numerical simulation responses of a set of eight-story buildings modelled by the commercial package for structural analysis ETABS. Different damage scenarios are considered by declining the Young’s modulus for the columns of the first and third stories by 10% or 20%. The stiffness components are accurately identified even when incompletely measured responses contain 10% noise are considered. The damaged stories are correctly located with accurate estimation of the damage severity. Then, to somewhat demonstrate the applicability of the procedure to a real building, the procedure is further employed to process the responses of eight-story steel frames under shaking table tests. These frames have different stiffness in the first, third, and sixth stories. The identified stiffness components accurately reflect the stories having different column stiffness.