摘要

抽除處理法是地下水污染現地整治技術之一,利用抽水井針對地下水污染源進行抽除,並輸送到地面的處理設施進行廢水處理,具有設置簡單且快速、維護成本及操作經驗需求較低等優點。本研究選定某地下水污染控制場址,其地下水受環丁碸及微量之揮發性有機物污染,因整治工法有規畫使用抽除處理技術,但抽出受污染地下無法符合該區域廢水處理場之進流標準(pH 6-9、環丁碸<5 mg/L、化學需氧量<80 mg/L),故需於廢水處理場進流端前建置一套廢水處理系統,考量到現地建置範圍及經費限制,比較溼式空氣氧化法、臭氧氧化法、芬頓化學氧化法、類芬頓化學氧化法後,本研究選定類芬頓化學氧化法,並以環丁碸(sulfolane)及化學需氧量(COD)去除率評估處理系統效能。研究顯示類芬頓化學氧化程序可有效礦化環丁碸及微量之揮發性有機物,惟處理後水樣COD仍介於100-200 mg/L,藉由增設一套活性炭吸附系統後,COD已符合廢水處理場進流標準。
於類芬頓化學氧化程序實驗中,最佳操作條件為過氧化氫濃度2%;三價鐵離子5 mM;螯合劑5 mM;反應時間24小時;操作容積10噸,再藉由搭配之活性炭吸附程序,去除殘留之過氧化氫後,出流水pH6-9,環丁碸去除率為99.8% (<5 mg/L),COD去除率為93.7%(<80 mg/L),已符合廢水處理場之進流標準,顯示此處理程序組合具有可行性。在成本分析方面,每噸廢水處理成本約3016元。
The multi-phase extraction is one of the groundwater pollution in-situ remediation technology. Using the pumping wells, we extract polluted groundwater and transport it to the treatment facilities. The advantages of multi-phase extraction are easy to install, low maintenance costs, and low operating experience requirements. A petrochemical-contaminated site in a petrochemical plant is chosen as the groundwater pollution control site. The groundwater was contaminated by sulfolane and traces of volatile organic compounds. The extraction technology was utilized in the original remediation project. However, the result cannot meet the required standards of the wastewater treatment plant (pH 6-9, sulfolane <5 mg/L, chemical oxygen demand <80 mg/L). Therefore, it is necessary to build another wastewater treatment system before the wastewater treatment plant's feeding flow. The Fenton-like chemical oxidation method is chosen as the remediation method. Sulfolane concentration and chemical oxygen demand(COD) removal rate are utilized to evaluate the efficiency of the treatment system. The research result shows that the Fenton-like chemical oxidation process can effectively mineralize sulfolane and trace volatile organic compounds. However, the COD after treatment is still in the range of 100-200 mg/L. The other activated carbon adsorption system connects behind the Fenton-like process. The COD finally meets the required standards of the wastewater treatment plant.
The optimum operating conditions of Fenton-like process in this study are listed as follows: [H2O2]=2%, [Fe2+]=5 mM, [chelating agent]=5 mM, reaction time= 24 hrs, reaction tank volume=10 ton. The activated carbon adsorption system installs behind the Fenton-like reaction tank. After removing the residual [H2O2], the effluent conditions lists as follows: pH6-9, sulfolane removal rate 99.8% (<5 mg/L), and COD removal rate 93.7% (<80 mg/L), which meets the feeding standard of the wastewater treatment plant. As a result, this combined treatment process is feasible. In terms of cost analysis, the operating cost of wastewater treatment per ton is about NT$3016.
顯示完整詮釋資料 統計資料

引用此條目

蔡旻庭 (2021). 使用類芬頓程序處理受污染之地下水 以某石化業污染場址為例. https://thesis.lib.nycu.edu.tw/handle/20.500.14371/76705

BibTeX RIS

引用文字依 APA 第 7 版格式自動產生,使用前請再核對。

分享

永久網址:https://thesis.lib.nycu.edu.tw/handle/20.500.14371/76705