使用微波退火氧銦鎵鋅薄膜應用於一氧化碳氣體感測之研究

Study of carbon monoxide gas sensor based on IGZO films by microwave annealing

檔案

全文未公開。

日期

2021

類型

語言

英文

摘要

銦鎵鋅氧化物(IGZO)是一種 n-type 金屬氧化物半導體材料,有對於環境中的光線及周遭氣體敏感的特性。這種材料通常被用於製作薄膜電晶體,由於具備上述特性,將銦鎵鋅氧化物用於製備氣體感測器的感測層,可以利用其對光線敏感的特性,以紫外光照射表面取代傳統加熱的方式,使銦鎵鋅氧化物表面產生光電子,並促使氧氣分子吸附在材料表面,進而提升氣體感測器的靈敏度。
本研究採用大氣電漿輔助化學氣相沉積(AP-PECVD)技術,將非晶態氧銦鎵鋅薄膜沉積於矽基板上,做為氣體感測器的感測層。大氣壓電漿輔助化學氣相沉積的優點是可在大氣環境下直接操作,不需要使用真空系統,不僅能夠降低製造及時間成本,更可以有效提高生產量。本研究將分為三個部分,第一部分為探討微波退火功率對於氣體感測之靈敏度,以測試出最適合的退火條件;第二部分為探討氣體感測器能夠量測到的最低濃度;第三部分為考量到現實環境中的實用性,量測氣體感測器的感測連續性與再現性。此實驗將最低濃度結合再現性,並比較量測結果。
本研究所使用的材料分析儀器有四種。第一種為熱場發射掃描式電子顯微鏡(SEM),第二種為場發射穿透式電子顯微鏡(TEM),第三種為多模式原子力顯微鏡(AFM),第四種為X光光電子能譜儀(XPS)。利用這些儀器分析的結果並搭配實際量測的靈敏度,來證明在功率550W,氧氣環境中進行100秒的微波退火條件下,使用紫外光驅動銦鎵鋅氧化物氣體感測器,對於一氧化碳感測能力的提升有顯著的效果,且成功量測出最低濃度並呈現再現性。 
Indium gallium zinc oxide (IGZO) is an n-type metal oxide semiconductor material, which is sensitive to light in the environment and surrounding gases. This material is usually used for thin film transistors (TFT). Because of the above-mentioned characteristics, indium gallium zinc oxide is used to prepare the sensing layer of gas sensors. Its light-sensitive characteristics can be used to irradiate the surface with ultraviolet light to replace the traditional heating method generating photoelectrons on the surface of indium gallium zinc oxide, and promotes the adsorption of oxygen molecules on the surface of the material, thereby enhancing the sensitivity of the gas sensor.
In this study, atmospheric plasma enhanced chemical vapor deposition (AP-PECVD) technology is used to deposit an amorphous oxide indium gallium zinc film (a-IGZO) on the silicon substrate as the sensing layer of the gas sensor. The advantage of atmospheric plasma enhanced chemical vapor deposition is that it can be directly operated in an atmospheric environment without the vacuum system, which can not only reduce manufacturing and time costs, but also effectively increase production. This study will be divided into three parts. The first part is discussing the sensitivity of microwave annealing power to gas sensing, so that we can get the most suitable microwave annealing conditions. The second part is measuring the lowest concentration of gases which the gas sensor can measure. The third part is considering the practicality in the real environment, measuring the sensing continuity and reproducibility of the gas sensor. This experiment combines the lowest concentration and the continuous measurement, and compares the results of experiment.
There are four kinds of material analysis instruments used in this research. The first one is Scanning Electron Microscope (SEM), the second one is Transmission Electron Microscope (TEM), the third one is Atomic Force Microscope (AFM), the fourth one is X-ray Photoelectron Spectroscopy (XPS). The results of these material analysis instruments and the sensitivity of the measurement show that under the power of 550 W microwave annealing in O2 environment for 100 seconds, the UV-light driven indium gallium zinc oxide gas sensor improves the sensing ability of carbon monoxide, so that we successfully measure the minimum concentration and represent the reproducibility.
顯示完整詮釋資料 統計資料

引用此條目

Yeh, H.-T. (2021). Study of carbon monoxide gas sensor based on IGZO films by microwave annealing. https://thesis.lib.nycu.edu.tw/handle/20.500.14371/77037

BibTeX RIS

引用文字依 APA 第 7 版格式自動產生,使用前請再核對。

分享

永久網址:https://thesis.lib.nycu.edu.tw/handle/20.500.14371/77037