基於慣性測量單元的即時三維足軌跡重建與電路設計
IMU-based Real-time 3D Foot Trajectory Reconstruction and Chip Implementation
摘要
近年來,足軌跡重建已在許多應用中受到重視,例如輔助疾病診斷和醫療、辨識多類別的運動動作。以慣性測量單元(IMU)進行足軌跡重建,有成本低,體積小的優點,非常適合穿戴式的應用。
本論文提出了一種可即時運算、計算複雜度低且保持高精確度的足部軌跡重建方法。所提出的演算法中由快速互補濾波器估計方向,然後對加速度進行二次積分,並採用零速度更新方法抑制積分漂移。軌跡重建的結果與動作捕捉系統Vicon交互驗證。實驗結果表明,該方法的平均誤差在X軸可達2.04±1.56 cm,在Y軸可達1.30±1.17 cm,在Z軸可達 1.43±0.95 cm。
為了實現邊緣計算,本論文以所提出的演算法設計晶片。晶片的設計遵循Cell-Based設計流程,並採用TSMC 0.18 um製程製作晶片。完成的晶片面積為2.571 x 2.575 mm2,在操作電壓1.8V、時脈170kHz的情況下功耗為0.35 mW。
本論文提出了一種可即時運算、計算複雜度低且保持高精確度的足部軌跡重建方法。所提出的演算法中由快速互補濾波器估計方向,然後對加速度進行二次積分,並採用零速度更新方法抑制積分漂移。軌跡重建的結果與動作捕捉系統Vicon交互驗證。實驗結果表明,該方法的平均誤差在X軸可達2.04±1.56 cm,在Y軸可達1.30±1.17 cm,在Z軸可達 1.43±0.95 cm。
為了實現邊緣計算,本論文以所提出的演算法設計晶片。晶片的設計遵循Cell-Based設計流程,並採用TSMC 0.18 um製程製作晶片。完成的晶片面積為2.571 x 2.575 mm2,在操作電壓1.8V、時脈170kHz的情況下功耗為0.35 mW。
In recent years, foot trajectory reconstruction has been valued in many applications, such as assisting disease diagnosis and medical treatment and recognizing multi-classes sports motion. The foot trajectory reconstruction with an inertial measurement unit (IMU) has the advantages of low cost and small size, which is very suitable for wearable applications.
This thesis proposes a foot trajectory reconstruction method that can be operated in real-time and has low computational complexity while keeping low error rate. The orientation is estimated by Fast Complementary Filter (FCF). Then the acceleration is integrated twice, and the zero velocity update (ZUPT) method is used to suppress the integral drift. The trajectory reconstruction result is verified with the motion capture system Vicon. Experimental results show that the error of the proposed method can achieve an average error of 2.04±1.56 cm on the x-axis, 1.30±1.17 cm on the y-axis, and 1.43±0.95 cm on the z-axis.
For edge computing, this thesis designed the chip with the proposed algorithm. Design of the chip follows the Cell-Based design flow and is implemented with TSMC 0.18 μm CMOS Process. The performance of the chip achieves an area of 2.571 x 2.575 mm2, the power consumption of 0.35 mW at an operating voltage of 1.8V, and a clock rate of 170kHz.
This thesis proposes a foot trajectory reconstruction method that can be operated in real-time and has low computational complexity while keeping low error rate. The orientation is estimated by Fast Complementary Filter (FCF). Then the acceleration is integrated twice, and the zero velocity update (ZUPT) method is used to suppress the integral drift. The trajectory reconstruction result is verified with the motion capture system Vicon. Experimental results show that the error of the proposed method can achieve an average error of 2.04±1.56 cm on the x-axis, 1.30±1.17 cm on the y-axis, and 1.43±0.95 cm on the z-axis.
For edge computing, this thesis designed the chip with the proposed algorithm. Design of the chip follows the Cell-Based design flow and is implemented with TSMC 0.18 μm CMOS Process. The performance of the chip achieves an area of 2.571 x 2.575 mm2, the power consumption of 0.35 mW at an operating voltage of 1.8V, and a clock rate of 170kHz.