摘要
隨著電晶體尺寸縮小,負責傳遞訊號的銅導線線寬及線距亦逐漸縮小,屆時將承受超過106A/cm2的電流密度,將會發生電遷移和應力遷移造成微結構上的破壞之可靠度問題。在過去的研究中銅微結構對於直接影響電遷移壽命的研究甚少,且由於製備電遷移試片過程中所造成的缺陷以及氧化所造成的影響,導致實驗結果通常伴隨著許多非微結構造成之因素,因此在本研究中結合雷射彎曲束系統(Bending Beam system)觀察不同微結構銅膜的應力鬆弛情形,不僅減少傳統電遷移測試耗時長的問題,也能直接推測微結構造成之影響。本研究透過在200oC持溫10小時觀察不同微結構的柱狀雙晶銅薄膜的熱應力鬆弛情形以預測電遷移壽命,實驗結果發現具有(111)優選方向和大晶粒雙晶銅會有較緩慢的應力鬆弛速率,但是由於雙晶銅強度高因此會擁有比一般銅更大的熱應力,為了釋放應力,雙晶銅表面會有突起(Protrusion)出現,此缺陷可能會穿透介電材料鈍化層使導線短路,因此透過蓋鈷金屬作為表面阻障層減緩該情形發生,提供銅在導線重佈層中一可行的解決方案。為了研究微結構對應力鬆弛的影響將透過FIB、SEM、EBSD、XRD等分析技術觀察微結構變化及可能擴散路徑影響應力鬆弛速率的原因,並透過不同預退火溫度調節整體薄膜應力以降低薄膜在應力鬆弛時應力梯度所造成之影響;此外由於過大的熱應力可能會使銅導線毀壞,透過奈米雙晶銅在一臨界溫度後,將會發生異常晶粒成長,且由於微結構改變,熱應力大幅下降,將減少可能的機械損壞,本研究也會探討其相關應力行為。
As the size of the transistor shrinks, the line width and line spacing of the copper wires responsible for transmitting signals are gradually shrinking. At that time, it will withstand a current density of more than 106A/cm2, and electromigration and stress migration will occur, which will cause the reliability problem. In the past studies, there are few studies on the copper microstructure directly affecting the electromigration life, and due to the defects caused by the process of preparing the electromigration test piece and the influence caused by oxidation, the experimental results are usually accompanied by many non-microstructures. Therefore, in this study, combined with the Bending Beam system to observe the stress relaxation of copper films with different microstructures, it not only reduces the time-consuming problem of traditional electromigration testing, but also directly infers the influences caused by microstructure. In this study, the thermal stress relaxation of columnar nanotwinned copper films with different microstructures was observed at 200oC for 10 hours to predict the electromigration lifetime. The experimental results found that the (111) preferred orientation and large-grain nanotwinned copper will have a slower stress relaxation rate, but due to the high strength of nanotwinned copper, it has greater thermal stress than random copper. In order to relieve the stress, there will be protrusion on the surface of nanotwinned copper. This defect may penetrate the dielectric material passivation layer result in short-circuits. Therefore, the cobalt can be used as a surface barrier layer to slow down this situation and provide a feasible solution for copper in the wire redistribution layer. In order to study the effect of microstructure on stress relaxation, FIB, SEM, EBSD, XRD and other analytical techniques will be used to observe the changes in microstructure. The overall film stress will be adjusted through different pre-annealing temperatures to reduce the film’s stress due to effect of the stress gradient during stress relaxation; in addition, because excessive thermal stress may destroy the copper wire, abnormal grain growth will occur after a critical temperature of nanotwinned copper, and due to the change of the microstructure, resulting in thermal stress significantly reduction and cut down the possible mechanical damage.