銀膠接合矽晶片與銅基板之微觀結構、剪應力強度 及熱傳導研究
Microstructure, Shear Strength, and Thermal Conductivity of Si Die Attach on Cu Substrate with Silver Paste
摘要
本研究利用不同顆粒大小銀膠接合矽(Si)晶片於銅(Cu)基板上,成功地克服兩者熱膨脹係數差異造成接合失效現象,試片接合是利用兩種不同大小銀顆粒(0.6、8 μm)銀膠,於150、250及350℃持溫15分鐘分別接合Si晶片與Cu基板。並進行Si晶片或Cu基板進行金屬化過程評估接合效果,金屬化鍍層為鈦(Ti)/鎳(Ni)/銀(Ag),將比較有無金屬化差異。實驗結果發現最佳接合試片為Si有金屬化層與Cu無金屬化層接合於250℃。Si晶片金屬化有助於銀膠與銀接合,故接合強度達到約21 MPa,接著使用此一參數於250℃大氣氣氛中進行500小時等溫時效試驗。等溫時效試驗後,銀膠中銀顆粒燒結良好,環氧樹脂散佈於燒結銀層中,而Cu基板上則出現薄且分布廣的Cu2O層,進而降低時效後接合強度,強度降至約15 MPa,且斷裂面多沿Cu2O層延伸;透過超音波掃描檢測(SAT)可以發現接合比率由時效前87%,經時效500小時後,顯著提高至97%;熱傳導性質方面,因樹脂熱傳導較差,0.6 μm小顆粒銀膠因銀顆粒/樹脂間界面較多,樹脂大量阻擋金屬顆粒間之熱傳導,具有較低之熱傳導係數(6.5~18.8 W/m∙K),反之,8 μm大顆粒之銀膠則有較高熱傳導係數(54.4~148 W/m∙K),比較傳統銀膠此銀膠具有更優異的散熱表現。
Two types of silver (Ag) pastes were used to bond silicon the (Si) chip and the copper (Cu) substrate and successfully overcomes the bonding failure between Si and Cu due to coefficient of thermal expansion (CTE) mismatch. The bonding samples were prepared by using the Ag pastes with two particle sizes of 0.6 and 8 μm, and then annealed at 150, 250 and 350℃ with 15 minutes. The Si chip and Cu substrate with or without metallization (Ti/Ni/Ag) will be evaluated in the study. The best bonding sample is that the Si chip with metallization bonded with the Cu substrate without metallization after annealing at 250℃. The bonding strength was measured as 21 MPa because the Ag metallization of Si chip will bond with the Ag paste. After the isothermal aging test in 250 and 500 hours in air, the Ag particles of the paste were completely changed into a dense Ag layer. But, the epoxy still existed in the Ag layer and a thin Cu2O layer spread in the pastes due to the reaction of Cu and oxygen (O). The Cu2O layer will reduce the bonding strength to 15 MPa after aging and the fracture surface mostly happened at the brittle Cu2O layer. By contrast, the bonding ratio has increased from 87% to 97% after aging for 500 hours performed by SAT analysis. As for the thermal conductivity, there are more epoxy existed around the small Ag particle and easily blocked the connection between Ag particles. The thermal conductivity of Si chip (metallization)/Cu substrate with 0.6 μm Ag paste after aging is 6.5~18.8 W/mK. On the contrary, the large particles of Ag paste has higher thermal conductivity (54.4 ~148 W/mK). Both kinds of bonding pastes have better thermal conductivity than traditional Ag paste.