應用功能性近紅外光光譜術於歷史科教學法評估:互動式響應系統輔助教學法與傳統講述教學法之比較

Applying functional near-infrared spectroscopy in history class for the course instruction evaluation: comparison between interactive response system- assisted instruction and traditional didactic instruction

檔案

日期

2021

類型

語言

中文

摘要

近年來隨著科技的日新月異,透過行動載具進行互動式教學的即時反饋機制可改善傳統授課中以講述為主的困境;目前多數研究中比較教學方式的優異時都是透過測驗成績、量表或問卷以及行為觀察等方式來進行評估,但隨著多元評量的興起以及考量到前述方法中衍生的社會期許偏誤和個人主觀評斷可能會降低研究的信度,為了避免前列問題,我們期望能夠應用功能性近紅外光光譜術來評估不同教學法於歷史課堂中的影響差異,以從生理角度來進行觀測並提供客觀且量化的評估依據。
鑒於前述,本研究基於非侵入式功能性近紅外光光譜術來同步量測課堂中學生的前額葉血氧濃度變化,總計共採集10筆傳統講述教學法與12筆互動式響應系統輔助教學法的血氧數據進行分析。首先,在個案探討方面將課堂事件記錄與血氧濃度變化趨勢進行對照後,從中發現到了與各項理論背景相應的生理實證;接著,在T檢定的統計結果中也確實能夠找到兩種教學法間具有顯著性差異的腦血氧資訊,並與認知負荷理論概念具有關聯性;最後,我們將經過處理的血氧特徵匯入不同的機器學習演算法來辨識教學法組別,而根據結果顯示,被選中的最佳特徵與認知負荷的影響有關,且從支援向量機、線性區別分析與二次區別分析三種分類器所得到的測試準確率分別可達85.7 %、71.4 %以及85.7 %的水準。
綜合前述結果證明藉由功能性近紅外光光譜術來評估教學法的可行性,並能夠進一步為相關理論提供神經科學上的實證。
With the rapid development of science and technology for the past few years, instant feedback of interactive instruction by mobile devices can improve the problems of traditional didactic instruction. Most studies compare the pros and cons of teaching methods by exam scores, scales or questionnaires, and behavioral observations. However, with the rise of multiple assessments, social desirability bias and subjective judgment of those approaches may reduce the reliability of results. To avoid these problems mentioned above, we expected to apply functional near-infrared spectroscopy (fNIRS) to evaluate teaching methods from the physiological point of view and provide an objective and quantitative basis of evaluation.
In this research, based on non-invasive fNIRS, we synchronously measured the changes in cerebral oxygen concentration in the prefrontal cortex during class. Furthermore, we acquired 10 data with traditional didactic instruction and 12 data with interactive response system-assisted instruction in total. First, in the case studies, we checked the real-time recordings during the lecture against the trend of changes in hemoglobin concentration. Through the results, we find empirically physiological evidence corresponding to several theoretical backgrounds. And then, T-test results also can indeed find significant differences between two instructions from cerebral oxygen information and be related to cognitive load theory. Finally, we fed the processed cerebral oxygen features into different machine learning algorithms to distinguish two instructions. Through the results, the best-selected features are relative to the effect of cognitive load, and the testing accuracy obtained by support vector machine (SVM), linear discriminant analysis (LDA), and quadratic discriminant analysis (QDA) classifiers can reach 85.7 percent, 71.4 percent, and 85.7 percent, respectively.
As mentioned above, the results prove the feasibility of instruction evaluation through fNIRS and can provide neuroscience evidence for the relevant theory.

所屬典藏

光電工程學系
顯示完整詮釋資料 統計資料

引用此條目

陳婉誼 (2021). 應用功能性近紅外光光譜術於歷史科教學法評估:互動式響應系統輔助教學法與傳統講述教學法之比較. https://thesis.lib.nycu.edu.tw/handle/20.500.14371/79098

BibTeX RIS

引用文字依 APA 第 7 版格式自動產生,使用前請再核對。

分享

永久網址:https://thesis.lib.nycu.edu.tw/handle/20.500.14371/79098