飛時測距儀之精密度與多通道雷射驅動器
Precision and Multi-Channel Laser Driver For a Time-Of-Flight Range Finder
摘要
為了朝向無動件式線性掃描光達邁進,本論文中設計了一種應用於線性掃描光達的四通道雷射驅動器,在開啟單一通道時最窄可以提供雷射 2 ns 的電流脈衝寬度、峰值電流可達 5 A、頻率可達 50 MHz,並產生最高 2 W 的雷射峰值功率與 5 mW 的平均功率。四個通道可以輪流進行開關,通道開啟以及關閉的切換時間分別約為 2 μs 與小於 1 μs,此設計提供了未來更多通道的雷射光源驅動器設計參考。
本研究將單光子雪崩二極體光達搭配直接飛行時間法應用進行高精密度量測,針對積分時間、直方圖半高寬、物體的反射率與雷射頻率等參數進行調變,再從中找到精密度與各參數間的關聯。最終在特定條件下達到了 15.6 μm 的測距精密度。同時我們也用數學模型去預測測距之精密度,並驗證了此模型準確度,最終得出在特定條件下可以符合實際測距的精密度。
本研究將單光子雪崩二極體光達搭配直接飛行時間法應用進行高精密度量測,針對積分時間、直方圖半高寬、物體的反射率與雷射頻率等參數進行調變,再從中找到精密度與各參數間的關聯。最終在特定條件下達到了 15.6 μm 的測距精密度。同時我們也用數學模型去預測測距之精密度,並驗證了此模型準確度,最終得出在特定條件下可以符合實際測距的精密度。
To move forward to a linear scanning LiDAR without any moving parts, we designed a multi-channel laser driver to drive the emitter of it. This multi-channel driver can provide 2-ns width pulse current for each laser, and its peak current can reach 5 A、frequency can reach 50 MHz, and the laser power is 2 W in the peak、5 mW in the average. The four channels of this driver can be turn on and off in turn, the turn on time is 2 μs、turn off time is 1μs. This design provided a reference for laser driver with more channel.
In the addition to self-driving applications, we tried to apply our single-photon avalanche diode LiDAR system on high precision measurement with direct time-of-flight method because there are few people work on it. We adjust several parameters such as integration time、full width half maximum of the histogram、reflectivity of the target and laser frequency to found how they affect precision. Finally, a ranging precision of 15.6 μm under certain condition was achieved. What’s more, we tried to build a mathematical model to derive a formula for predicting the precision of multiple ranging results by a single ranging histogram, and we also verified it. Finally, it was concluded that this formula can be very effective under certain conditions.
In the addition to self-driving applications, we tried to apply our single-photon avalanche diode LiDAR system on high precision measurement with direct time-of-flight method because there are few people work on it. We adjust several parameters such as integration time、full width half maximum of the histogram、reflectivity of the target and laser frequency to found how they affect precision. Finally, a ranging precision of 15.6 μm under certain condition was achieved. What’s more, we tried to build a mathematical model to derive a formula for predicting the precision of multiple ranging results by a single ranging histogram, and we also verified it. Finally, it was concluded that this formula can be very effective under certain conditions.