心電訊號雜訊抑制演算法於物聯網平台之應用
顯示簡易詮釋資料 統計資料| 欄位 | 內容 | 語言 |
|---|---|---|
dc.contributor.advisor |
伍紹勳 | |
dc.contributor.advisor |
Wu, Sau-Hsuan | |
dc.contributor.author |
林昱彣 | |
dc.contributor.author |
Lin, Yu-Wen | |
dc.contributor.college |
電機學院 | |
dc.contributor.committee |
趙禧綠 | |
dc.contributor.committee |
劉秉彥 | |
dc.contributor.committee |
莊正彥 | |
dc.contributor.committee |
李柏增 | |
dc.contributor.committee |
黃鼎鈞 | |
dc.contributor.committee |
Chao, Hsi-Lu | |
dc.contributor.committee |
Liu, Ping-Yen | |
dc.contributor.committee |
Chuang, Cheng-Yen | |
dc.contributor.committee |
Lee, Po-Tseng | |
dc.contributor.committee |
Huang, Ting-Chun | |
dc.contributor.department |
生醫工程研究所 | |
dc.contributor.studentid |
0860429 | |
dc.date.NCLavailable |
2027/03/07 | |
dc.date.USTavailable |
2025/03/07 | |
dc.date.issued |
2022 | |
dc.date.issuedROC |
111 | |
dc.date.paperavailable |
立即公開 | |
dc.date.schoolyear |
110 | |
dc.description.abstract |
根據我國衛生福利部於2019年統計,心血管疾病高居國人十大死因排名第二名,其中又以45歲以上之族群為大宗。診斷心血管疾病的其中一種方式是檢查心電圖,心臟透過心肌的收縮及舒張運送血液至全身各處,運送中所產生的微弱電流變化經由黏貼於皮膚上的電極量測而得,經記錄及分析後輸出即為心電圖。心臟專科醫師透過各種檢驗方式來檢測患者心臟狀況,而心電圖是其中最廣泛被應用的方式之一。 隨著全球進入高齡化社會,心血管疾病患者又以中高齡為大宗,患者在進行心導管手術、血管繞道手術後,無論住院或返家,皆需要持續進行術後的監測,而醫院內傳統的標準十二導極心電圖儀,體積龐大且導線纏身,不利於長時間監測患者心臟狀況。隨著醫療器材的發展,無線心電圖儀具備攜帶性高、不受導線限制、較不影響患者行動等優點,能協助醫師透過雲端平台隨時掌握患者心電圖狀況,有助於做出更即時的診斷或治療。然而,隨著配戴時間的增加,心電訊號的量測難免因患者走路、運動、或進行復健等因素而受到雜訊干擾,進而影響醫師對心電圖的判讀。 常見的雜訊來源可分為三種,分別是:Baseline wander(基準線飄移),是由呼吸、充電電極或是目標物移動造成的雜訊;Muscle artifact(肌電雜訊),來自當電極貼在皮膚上時,同時測到的肌肉運動訊號;以及electrode motion artifact(動作假影),是由電極及皮膚間阻抗改變造成的雜訊。這三種雜訊當中,動作假影雜訊造成的波形改變幅度較大,頻率與靜態心電訊號較相近,因此較難處理。 本研究利用類神經網路建立之深度學習模型,針對動作假影雜訊進行雜訊抑制,對深度學習模型進行訓練時,需要有相對應可被判讀的心電訊號做為模型的訓練目標,但真實情況下,我們無法得知受雜訊干擾的心電訊號,其同一時間下可判讀的心電訊號,因此本研究使用來自PhysioBank提供的PTB-XL資料庫[1],做為靜態可判讀的心電訊號來源。 本研究中使用由MITBIH提供的Noise Stress Test Database (NSTDB)[2],並選擇被標記為Electrode motion artifact (EM)的資料作為一部分雜訊來源,另外亦使用到由新光吳火獅紀念醫院心臟內科門診收集之ECG訊號,其中包含上肢復健運動、走路等運動中所收集的資料,使雜訊來源更為多元,並分別針對不同動作分析此模型架構對於各動作所產生雜訊的抑制效果。 | |
dc.description.abstract |
According to the Ministry of Health and Welfare of Taiwan, cardiovascular diseases (CVDs) ranked in second place of the top ten leading causes of death. Patients over 45 years old accounted for the majority. One of the methods for diagnosing heart diseases is monitoring the electrocardiogram (ECG). By the contraction and relaxation of cardiac muscle, blood travels through the whole body. Small electrical changes generated during the transportation are measured using the electrodes attached to the body surface. After recordings and analyses, an electrocardiogram is then produced with the electrical potential. Cardiologists or clinicians examine conditions of patients’ heart, and electrocardiograms are among the most widely used measurements. With the globally societal aging and the wide population of aged patients suffering from CVDs, every postoperative patient done with a cardiac catheterization or a bypass surgery needs to be closely monitored. Nevertheless, the bulkiness of the conventional 12-lead ECG monitors is unfavorable for long-term monitoring. With the development of medical equipment, the mobility and convenience of wireless ECG devices help physicians to monitor patients’ real-time ECG through the cloud platform. Immediate diagnosis or further treatment can thus be done by the assistant of the platform. However, due to the growth of wearing time, the ECG waveforms are easily contaminated by noises while walking, exercising, or rehabilitation, and this might mislead the physicians while diagnosing. There are three kinds of noises commonly seen in ECG, including muscle artifact (MA), baseline wander (BW), and electrode motion artifact (EM). For instance, baseline wander is a kind of artifact of low frequency generated due to subject movement, showing an undulating baseline on ECG signals. Muscle artifacts are produced by activations of skeletal muscle, presenting signals with high frequency on ECG. Electrode motion artifact noises result from motion of the electrodes placed on patients’ skin, and may present signals with large amplitude and deformed morphology. These noisy ECG waveforms might result in misdiagnosis by the clinicians or automated systems. The propose approach is a deep learning-based model specified for noise reduction of motion artifact noises. ECG data from PTB-XL database are used as clean inputs, while data from Noise Stress Test Database (NSTDB) are used as source of noisy inputs. Noisy ECG signals are also collected from outpatients from a cooperative hospital, so as to enrich the diversity of noisy inputs. The results of the proposed method show the capability of deep learning-based model for reducing noises from noisy ECG waveforms. | |
dc.description.abstractopendate |
2022/03/10 | |
dc.description.degree |
碩士 | |
dc.description.tableofcontents |
摘 要 iAbstract ii誌謝 ivContent vList of Tables viList of Figures viiChapter 1 Introduction 11.1 Motivation and Background 11.2 Related Work 41.3 Contribution 5Chapter 2 System 62.1 Traditional ECG Monitors 62.2 Wireless ECG-based Healthcare IoT System 7Chapter 3 Algorithms 103.1 Problem Formulation 103.2 Denoising Auto-Encoder 103.3 Variational Auto-Encoder 133.4 Long Short-Term Memory 153.5 Generative-Adversarial Network 18Chapter 4 Experimental Results 214.1 Experimental Designs 214.2 Database Source 254.3 Data-Preprocessing 294.4 Results 304.5 Comparison between different Models 31Chapter 5 Applications on ECG System 365.1 AF Detection Results with Clean ECG 365.2 AF detection results with Reconstructed ECG 425.3 Synthesis of Conventional 12-lead ECG 43Chapter 6 Discussion 466.1 Wrong detection cases of AF using reconstructed ECG 46Chapter 7 Conclusion 48Reference 49 | |
dc.identifier.citation |
[1] P. Wagner, N. Strodthoff, R. Bousseljot, W. Samek, T. Schaeffter, “PTB-XL, a large publicly available electrocardiography dataset,” Sci Data 7, 154 (2020). https://doi.org/10.1038/s41597-020-0495-6[2] G. B. Moody, W. E. Muldrow, R. G. Mark, “A noise stress test for arrhythmia detectors,” Computers in Cardiology. 1984; 11:381-384.[3] N. E. Huang et al., ‘‘The empirical mode decomposition and the Hilbert spectrum for nonlinear and non-stationary time series analysis,’’ Proc. Roy. Soc. London Ser. A, Math., Phys. Eng. Sci., vol. 454, no. 1971, pp. 903–995, Mar. 1998[4] B. Manuel, B. W. Weng, B. Kenneth, “ECG signal denoising and baseline wander correction based on the empirical mode decomposition,” Computers in biology and medicine. 38. 1-13. 10.1016/j.compbiomed.2007.06.003.[5] H. Y. Lin, S. Y. Liang, Y. L. Ho, Y. H. Lin and H. P. Ma, “Discrete-wavelet-transform-based noise removal and feature extraction for ECG signals,” IRBM. 35. 10.1016/j.irbm.2014.10.004.[6] G. H. Lu et al. “Removing ECG noise from surface EMG signals using adaptive filtering.” Neuroscience letters vol. 462,1 (2009): 14-9. doi:10.1016/j.neulet.2009.06.063[7] X. Peng, H. R. Wang, M. Liu, S. P. Zhou, Z. G. Hou and X. L. Liu, “ECG signal enhancement based on improved denoising auto-encoder,” Engineering Applications of Artificial Intelligence. 52. 194-202. 10.1016/j.engappai.2016.02.015.[8] H. T. Chiang, Y. Y. Hsieh, S. W. Fu, K. H. Hung, Y. Tsao and S. Y. Chien, "Noise Reduction in ECG Signals Using Fully Convolutional Denoising Autoencoders," in IEEE Access, vol. 7, pp. 60806-60813, 2019, doi: 10.1109/ACCESS.2019.2912036.[9] K. Antczak, "Deep recurrent neural networks for ECG signal denoising." arXiv preprint arXiv:1807.11551 (2018).[10] P. Vincent, H. Larochelle, Y. Bengio and P. A. Manzagol, “Extracting and composing robust features with denoising autoencoders,” Proceedings of the 25th International Conference on Machine Learning. 1096-1103. 10.1145/1390156.1390294 (2008).[11] J. Pan and W. J. Tompkins, “A Real-Time QRS Detection Algorithm,” in IEEE Transactions on Biomedical Engineering, vol. BME-32, no. 3, pp. 230-236, March 1985, doi: 10.1109/TBME.1985.325532.[12] M. Abadi, P. Barham, J. M. Chen, Z. F. Chen, A. Davis, J. Dean, M. Devin, S.Ghemawat, G. Irving, M. Isard and et al, “TensorFlow: A System for Large-ScaleMachine Learning,” in Proceedings of 12th USENIX Symposium on. OperatingSystems Design and Implementation, 2016.[13] Y. C. Chang, S. H. Wu, L. M. Tseng, H. L. Chao and C. H. Ko, “AF Detection by Exploiting the Spectral and Temporal Characteristics of ECG Signals with the LSTM Model,” Computing in Cardiology Conference, CinC 2018. IEEE Computer Society.[14] G. B. Moody and R. G. Mark, “A new method for detecting atrial fibrillation using R-R intervals,” Computers in Cardiology. 10:227-230 (1983).[15] S. Petrutiu, A. V. Sahakian and S. Swiryn, “Abrupt changes in fibrillatory wave characteristics at the termination of paroxysmal atrial fibrillation in humans,” Europace 9:466-470 (2007).[16] F. M. Nolle, F. K. Badura, J. M. Catlett, R. W. Bowser and M. H. Sketch, “CREI-GARD, a new concept in computerized arrhythmia monitoring systems,” Computers in Cardiology 13:515-518 (1986).[17] A. Goldberger, L. Amaral, L. Glass, J. Hausdorff, P. C. Ivanov, R. Mark, H. E. Stanley, “PhysioBank, PhysioToolkit, and PhysioNet: Components of a new research resource for complex physiologic signals,” Circulation, 101 (23), pp. e215–e220 (2000).[18] A. Taddei, G. Distante, M. Emdin, P. Pisani, G. B. Moody, C. Zeelenberg and C.Marchesi, “The European ST-T Database: Standard for Evaluating Systems forthe Analysis of ST-T Changes in Ambulatory Electrocardiography,” EuropeanHeart Journal, vol. 13, no. 9, p. 1164–1172, Sep. 1992.[19] D. P. Kingma, M. Welling, “Auto-Encoding Variational Bayes,” 2nd International Conference on Learning Representations, ICLR 2014, Banff, AB, Canada, April 14-16, 2014, Conference Track Proceedings.[20] S. Hochreiter, J. Schmidhuber, “Long Short-term Memory,” Neural computation, 9. 1735-80. 10.1162/neco.1997.9.8.1735.[21] I. J. Goodfellow, J. Pouget-Abadie, M. Mirza, B. Xu, D. Warde-Farley, S. Ozair, A. Courville, Y. Bengio, “Generative Adversarial Networks”, Advances in Neural Information Processing Systems, 3. 10.1145/3422622 (2014).[22] G. B. Moody, W. E. Muldrow, R. G. Mark, “A noise stress test for arrhythmia detectors,” Computers in Cardiology, 11:381-384 (1984). | |
dc.identifier.uri |
https://hdl.handle.net/20.500.14371/79639 | |
dc.language.iso |
英文 | |
dc.relation.alma |
991003697594906772 | |
dc.relation.page |
50 | |
dc.subject.keyword |
心電圖 | |
dc.subject.keyword |
心電訊號 | |
dc.subject.keyword |
雜訊抑制 | |
dc.subject.keyword |
動作假影 | |
dc.subject.keyword |
穿戴式裝置 | |
dc.subject.keyword |
ECG | |
dc.subject.keyword |
EKG | |
dc.subject.keyword |
Noise Suppression | |
dc.subject.keyword |
Motion artifact | |
dc.subject.keyword |
NSTDB | |
dc.subject.keyword |
Wearable device | |
dc.title |
心電訊號雜訊抑制演算法於物聯網平台之應用 | zh-TW |
dc.title |
Implementation of ECG Noise Suppression Methods on IoT Platform | en |
dc.type |
Thesis | zh-TW |
檔案
全文將於 2027年3月7日 起公開。
所屬典藏: 生醫工程研究所