研發氧化鎵鋅之一氧化氮氣體感測器特性研究與其電路模組之開發
Study on the Performance of NO Gas Sensor Made of ZnGa2O4 and Relative Circuit Module Development
摘要
本研究利用有機金屬化學氣相沉積法成功於藍寶石基板上成長ZnGa2O4(ZGO)與ZnO薄膜,將其製作氣體感測器並探討其可能之感測模型。
第一部分為比較ZGO與ZnO於感測器量測裝置以及Wi-Fi電路板系統,並間接驗證Wi-Fi電路板系統之可行性。經由測試ZnO可以整合至Wi-Fi電路板系統上但ZGO受限於氣體響應度過小而無法整合。當氣體響應度於感測器量測裝置上低於15%,到電路板上時會無法量測,而在電路板上量測結果計算出之氣體響應度約為感測器量測裝置之2至2.6倍,依據5、2.5、1以及0.5 ppm排序為70%、188.08%、93.92%以及57.35%,線性度達0.9525。
第二部分對ZGO進行Si離子佈植處理,Si離子佈植1015之氣體響應度依據5、2.5、1以及0.5 ppm排序與未處理之相比,分別提昇364.77%、277.72%、185.7%以及121.9%,線性度達0.9272。而於材料分析之結果推測出其基礎電阻值變大為氣體響應度提昇之主要原因,而晶粒尺寸縮小與氧空缺比例上升為可能之原因。
第一部分為比較ZGO與ZnO於感測器量測裝置以及Wi-Fi電路板系統,並間接驗證Wi-Fi電路板系統之可行性。經由測試ZnO可以整合至Wi-Fi電路板系統上但ZGO受限於氣體響應度過小而無法整合。當氣體響應度於感測器量測裝置上低於15%,到電路板上時會無法量測,而在電路板上量測結果計算出之氣體響應度約為感測器量測裝置之2至2.6倍,依據5、2.5、1以及0.5 ppm排序為70%、188.08%、93.92%以及57.35%,線性度達0.9525。
第二部分對ZGO進行Si離子佈植處理,Si離子佈植1015之氣體響應度依據5、2.5、1以及0.5 ppm排序與未處理之相比,分別提昇364.77%、277.72%、185.7%以及121.9%,線性度達0.9272。而於材料分析之結果推測出其基礎電阻值變大為氣體響應度提昇之主要原因,而晶粒尺寸縮小與氧空缺比例上升為可能之原因。
In this study, ZnGa2O4 (ZGO) and ZnO thin films were successfully grown on sapphire substrates by Metal Oxide Chemical Vapor Deposition (MOCVD) to fabricate gas sensors and explore the possible sensing models.
The first section compares ZGO and ZnO in sensor measurement devices and Wi-Fi board systems, and indirectly verifies the feasibility of Wi-Fi board systems. The gas responsivity calculated from the measurement results on the board is about 2 to 2.6 times of that on the sensor measurement device, with 70%, 188.08%, 93.92%, and 57.35% based on 5, 2.5, 1, and 0.5 ppm, with a linearity of 0.9525.
In the second part, ZGO was treated with Si ion implantation, and the gaseous responsivity of Si ion implantation 1015 was increased by 364.77%, 277.72%, 185.7%, and 121.9% in the order of 5, 2.5, 1, and 0.5 ppm, respectively, compared with that of untreated ZGO, with a linearity of 0.9272.
The first section compares ZGO and ZnO in sensor measurement devices and Wi-Fi board systems, and indirectly verifies the feasibility of Wi-Fi board systems. The gas responsivity calculated from the measurement results on the board is about 2 to 2.6 times of that on the sensor measurement device, with 70%, 188.08%, 93.92%, and 57.35% based on 5, 2.5, 1, and 0.5 ppm, with a linearity of 0.9525.
In the second part, ZGO was treated with Si ion implantation, and the gaseous responsivity of Si ion implantation 1015 was increased by 364.77%, 277.72%, 185.7%, and 121.9% in the order of 5, 2.5, 1, and 0.5 ppm, respectively, compared with that of untreated ZGO, with a linearity of 0.9272.