電場下液滴動力學之研究與控制
Control and Investigation of Droplet Dynamics under Electrical Field
摘要
本次研究將以探討基礎電濕潤現象為出發點,了解其原理並觀察水滴於不同的電場分布狀態時的運動方式;之後,也進行了數顆水滴於具有網格的電極的試片上隨機生長並施加電壓產生電濕潤效果的實驗。首先,我們發現具有正負電壓交錯的正弦波對於單一水滴具有較高的移動能力,另外,若施加直流電且讓水滴置於一個電場分布極不平均的狀態,水滴也不會進行移動。對於多顆水滴的實驗則發現,水滴在成長並相互結合的同時也會逐漸朝向網格中心集中,而這個現象在低頻正弦波的施加下最為明顯。另外,本文討論了在低(1Hz,5Hz)和高(500Hz,1000Hz)AC-EWOD頻率下多層結構網格電極線圖案EWOD樣品的不同冷凝液滴分佈模式。在低頻下,冷凝液滴停留在網格內;在高頻下,冷凝液滴附著在網格線上。通過發現接觸角完全恢復和接觸角部分恢復振盪模式來研究單一液滴 (1μL) 動力學。這兩種模式導致不同的液滴聚結機制和分佈方式,對此,引入自然響應頻率來驗證這兩種模式。在 2Hz、50Hz、100Hz 和 200Hz 下對 0.5mm、1mm 和 2mm 網格樣品進行了冷凝液滴分佈的可視化實驗。同時,收集冷凝水以研究網格尺寸(0.5mm、1mm、2mm)在頻率(1Hz、100Hz、200Hz)對冷凝率的影響。較高的頻率比較低的頻率顯示出更大的冷凝率;與 0.5mm 和 2mm 網格樣品相比,1mm 網格樣品顯示出更好的結果。EWOD提供了一種主動和可逆的方式來干擾液滴動力學,促進冷凝液滴的生長和聚結,這在液滴控制和冷凝增強方面的未來應用中顯示出巨大的潛力。
This study started from the exploring the electrowetting phenomenon, understanding its principle, and analyzing the movement of droplets in various electric field, followed by setting up experiments to investigate droplets randomly grown on the samples of grid-type electrodes with various voltages. We found that a sine wave alternating voltage produced a higher mobility of a single droplet. Conversely, the droplet did not move when a DC power was applied even if it was placed in an extremely nonuniform electric field. For the experiments with multiple droplets, as the droplets grew and merged together, they gradually concentrated toward the center of the grid. This phenomenon was obvious when a sine wave alternating voltage was applied. Furthermore, distinct droplet distribution patterns of multi-layer open-plate grid-wire-patterned EWOD devices under low (1Hz, 5Hz) and high (500Hz, 1000Hz) frequencies of AC-EWOD were examined in this study. Under low frequencies, droplets stayed inside the grid; under high frequencies, droplets adhered to the grid wires. Single droplet (1μL) dynamics were studied with a discovery of contact-angle-fully-recover and contact-angle-partially-recover oscillation modes. These two modes induced distinct droplet coalescence mechanisms and distribution patterns. The natural response frequency was introduced to validate these two modes. Visualization experiments of droplet distribution were carried out on 0.5mm, 1mm, and 2mm grid samples under 2Hz, 50Hz, 100Hz, and 200Hz. Condensate was collected to investigate the grid size (0.5mm, 1mm, 2mm) and frequency effect (1Hz, 100Hz, 200Hz) on condensation rate. Higher frequency demonstrated a larger condensation rate than the lower ones; the 1mm grid samples showed more inspiring results compared with the 0.5mm and 2mm grid samples. EWOD provided an active and reversible way to interfere with droplet dynamics, and promote droplet growth and coalescence, which demonstrated great potential for applications in droplet control and condensation enhancement.