利用三軸加速度計推測橋墩沖刷深度 -以白布帆大橋為例
Estimating the scouring depth of bridge piers by using a triaxial accelerometer-A case study of Baibufan bridge
摘要
近年台灣受到極端氣候的影響,降雨強度呈現上升的趨勢,強降雨的產生也加劇了洪水對於橋梁基礎的影響,而橋樑周圍基礎土石的沖刷,更是橋梁破壞的主因,因此即時的連續監測橋墩沖刷深度對於災害的預警十分的重要。而目前大部分的橋梁監測系統多以非接觸式之水位量測作為橋梁安全地判定基準,而傳統水下量測儀器又需安裝於橋墩周圍土石中,往往費時耗力,並容易在洪水事件中損壞,因此利用橋梁振動檢測方式估算沖刷深度,逐漸成為了近年研究的趨勢。本研究透過橋墩基礎遭受到沖刷時,其基礎承載力降低,致使結構勁度(stiffness)改變,進而影響結構系統之自然頻率的特性進行分析。首先本實驗室開發可連續監測之三軸加速度計量測設備,並將量測到之加速度轉換成頻率,接著導入本研究所回歸之公式即時換算橋墩基礎沖刷深度,並以實驗室水槽試驗與白布帆大橋現地沖刷監測驗證結果。
本研究首先進行十六組水槽實驗,結果顯示在平衡沖刷時,橋墩沿渠寬向與沿水流方向之振動訊號,其與覆土深度之相關係數皆有超過0.87,經由另外四組驗證結果發現平均誤差為9.7%,但其沿橋墩軸向振動頻率相關係數則不足0.20,顯示水平振動頻率與橋墩平衡時之覆土深度呈現高度相關,垂向則較無明顯關聯。另外本研究也以振動頻率、單寬流量、橋墩直徑、底床中值粒徑以及沖刷深度建立無因次公式,驗證結果發現水平振動訊號誤差平均誤差為8.4%,而沿橋墩軸向振動頻率誤差高達40.1%,其趨勢與上述實驗直接回歸結果相似,但精確度較佳,顯示無因次公式對於評估水槽平衡沖刷深度的掌握性高。在現地實驗的部分,本研究在現場橋墩自然頻率分析上,成功辨識出橋墩在洪峰受水流衝擊激發出5~8(Hz)的共振頻率,接著應用上述頻率-沖刷回歸公式與推導之無因次公式於現地沖刷研究上,誤差則較為顯著;為了修正估算結果,本研究以沖刷粒子(Float-out device)之沖刷資料進行頻率-沖刷回歸公式之重新建立,而頻率-覆土深度之回歸公式在橋墩水平方向(橋台車流向)振動頻率回歸相關性達0.86以上,平均誤差僅有19.3%,誤差可大幅改善;無因次公式則以沖刷粒子之沖刷資料、大尺度質點追蹤法(Large scale Particle Image Velocimetry, LSPIV)計算橋墩周圍流速之水理資料來進行無因次公式之校正,其平均誤差為16.2%,顯示能應用於現地量測上。
關鍵字:白布帆大橋、三軸加速度計、橋墩沖刷、橋墩振動
本研究首先進行十六組水槽實驗,結果顯示在平衡沖刷時,橋墩沿渠寬向與沿水流方向之振動訊號,其與覆土深度之相關係數皆有超過0.87,經由另外四組驗證結果發現平均誤差為9.7%,但其沿橋墩軸向振動頻率相關係數則不足0.20,顯示水平振動頻率與橋墩平衡時之覆土深度呈現高度相關,垂向則較無明顯關聯。另外本研究也以振動頻率、單寬流量、橋墩直徑、底床中值粒徑以及沖刷深度建立無因次公式,驗證結果發現水平振動訊號誤差平均誤差為8.4%,而沿橋墩軸向振動頻率誤差高達40.1%,其趨勢與上述實驗直接回歸結果相似,但精確度較佳,顯示無因次公式對於評估水槽平衡沖刷深度的掌握性高。在現地實驗的部分,本研究在現場橋墩自然頻率分析上,成功辨識出橋墩在洪峰受水流衝擊激發出5~8(Hz)的共振頻率,接著應用上述頻率-沖刷回歸公式與推導之無因次公式於現地沖刷研究上,誤差則較為顯著;為了修正估算結果,本研究以沖刷粒子(Float-out device)之沖刷資料進行頻率-沖刷回歸公式之重新建立,而頻率-覆土深度之回歸公式在橋墩水平方向(橋台車流向)振動頻率回歸相關性達0.86以上,平均誤差僅有19.3%,誤差可大幅改善;無因次公式則以沖刷粒子之沖刷資料、大尺度質點追蹤法(Large scale Particle Image Velocimetry, LSPIV)計算橋墩周圍流速之水理資料來進行無因次公式之校正,其平均誤差為16.2%,顯示能應用於現地量測上。
關鍵字:白布帆大橋、三軸加速度計、橋墩沖刷、橋墩振動
In recent years, Taiwan has suffered from extreme weather, and rainfall intensity is getting heavier. The consequences of heavy rainfall have also aggravated the impact of floods, particularly the scours on bridge foundations. That is the main reason for bridge damage. Continuous real-time monitoring of bridge piers is essential for early warning for preventing disasters. However, most of the present bridge monitoring systems use the non-contact water level approach as the benchmark for bridge safety determination. However, the traditional underwater measurement instruments need to be installed in the soil and rock around the pier, which often costs massive financial and labor. That is also prone to damage by floods. Therefore, the use of bridge vibration detection methods to estimate the scour depth has gradually become popular in recent years. This study measured the variations of the natural frequency of the structural system due to the pier foundation being scoured, which foundation bearing capacity is reduced, resulting in a change in the structural stiffness. First of all, our laboratory designed an instrument of triaxial accelerometer measuring device for continuously monitoring. Through signal conversion, the measured acceleration is converted into frequency. Then the regression formula provided by our laboratory is imported to convert the real-time scours from the bridge pier. Finally, the measurement from flume experiments and the in-situ scouring monitoring of the Baibufan Bridge are examined for validation.
This study conducted sixteen flume experiments to test our method. The results showed that the relations between the vibration signal along the direction of the channel width and along the direction of the water flow, compared to the scour depth of the pier, exceeded 0.87. However, the relation of the vibration frequency along the axial direction of the pier is less than 0.20. That indicated that the horizontal vibration frequency is highly correlated with pier scour to the balanced scours, but there is no apparent correlation in the vertical direction. Besides, this study also established a dimensionless formula based on the vibration frequency, flow rate, pier diameter, median particle size of the bed, and scour depth. The results of dimensionless formulae showed that the scour mean error estimated by the horizontal vibration signal was less than 8.4%. The errors along the axial direction of the bridge piers were 40.1%. This trend is similar to the direct regression results from the above experiments but performed with better accuracy than above. The comparison revealed that the dimensionless formula better evaluates the balanced scours in flume experiments. In situ monitoring, this study identified the resonance frequency of 5-8 (Hz) excited by the impact of the water flow on the bridge pier in the natural frequency analysis. And then, we applied the above frequency-scour regression and dimensionless formulas to the Baibufan Bridge scouring. The study obtained significant errors. This study used the in-situ scouring data from the float-out devices to re-establish the frequency-scour regression formula to improve the results. The results showed the relationship between vibration frequency and pier scour in the horizontal direction of the bridge pier (the flow direction of the bridge platform vehicle) excess 0.86, and the average error is 19.3%. The error is significantly reduced. The study also used the LSPIV (Large Scale Particle Image Velocimetry) to calculate the flow velocity around the pier. And, the average error is 16.2%, which shows that the corrected dimensionless formula can be well used in field application.
Keywords: Baibufan Bridge, triaxial accelerometer, pier scouring, pier vibration.
This study conducted sixteen flume experiments to test our method. The results showed that the relations between the vibration signal along the direction of the channel width and along the direction of the water flow, compared to the scour depth of the pier, exceeded 0.87. However, the relation of the vibration frequency along the axial direction of the pier is less than 0.20. That indicated that the horizontal vibration frequency is highly correlated with pier scour to the balanced scours, but there is no apparent correlation in the vertical direction. Besides, this study also established a dimensionless formula based on the vibration frequency, flow rate, pier diameter, median particle size of the bed, and scour depth. The results of dimensionless formulae showed that the scour mean error estimated by the horizontal vibration signal was less than 8.4%. The errors along the axial direction of the bridge piers were 40.1%. This trend is similar to the direct regression results from the above experiments but performed with better accuracy than above. The comparison revealed that the dimensionless formula better evaluates the balanced scours in flume experiments. In situ monitoring, this study identified the resonance frequency of 5-8 (Hz) excited by the impact of the water flow on the bridge pier in the natural frequency analysis. And then, we applied the above frequency-scour regression and dimensionless formulas to the Baibufan Bridge scouring. The study obtained significant errors. This study used the in-situ scouring data from the float-out devices to re-establish the frequency-scour regression formula to improve the results. The results showed the relationship between vibration frequency and pier scour in the horizontal direction of the bridge pier (the flow direction of the bridge platform vehicle) excess 0.86, and the average error is 19.3%. The error is significantly reduced. The study also used the LSPIV (Large Scale Particle Image Velocimetry) to calculate the flow velocity around the pier. And, the average error is 16.2%, which shows that the corrected dimensionless formula can be well used in field application.
Keywords: Baibufan Bridge, triaxial accelerometer, pier scouring, pier vibration.