摘要

生物感測器(Biosensor)是用來檢驗生物要素與物理化學要素的重要感測器,在各式生物感測晶片設計中,利用微懸臂樑來當作訊號轉換器是主要作法之一,其作法是藉由量測懸臂樑吸附特定生化物質後的自然頻率變化來推估生化物質的濃度。本研究採用實驗室先前設計之壓阻式電熱驅動振盪器[1],結合鎖相迴路(Phase Lock Loop, PLL)自動追蹤振盪器的自然頻率。
電熱驅動振盪器的實驗結果顯示該元件存在feedthrough現象,且內部惠斯同電橋中電阻值無法完全匹配,此二現象造成的干擾訊號大小比振盪器位移訊號大60 dB,且不易藉由濾波器直接濾除。本研究針對上述情形設計一個數位控制器,透過Simulink模擬驗證此控制架構的穩定性與可行性。最終利用一塊數位開發板來模擬電熱驅動氣的動態響應,以另一塊數位開發板來實現控制流程,完成控制電路的Hardware-in-the-Loop測試。
實驗結果顯示,在上述干擾訊號存在的情形下,當振盪器的自然頻率分別為92kHz、95kHz和98kHz時,所設計的頻率自動追蹤電路分別鎖定在90.3kHz、93.7kHz和96.5kHz。所設計的頻率自動追蹤電路可在大干擾訊號存在的狀況下成功鎖定振盪器的自然頻率。
Biosensor is an important sensor used in measuring the biological and/ or chemical reactions. One major approach for designing such sensors is to use the microcantilevers as a signal converter. The concentration of biochemical substances is estimated by measuring the shift of the resonance frequency of the cantilever beam after the cantilever beam adopting specific biochemical substances.
In this study, we aim to design a natural frequency tracking algorithm for the electrothermal actuated micro-resonator developed in our laboratory before. According to the experimental results, the developed resonator not only exhibited feedthrough phenomenon, but also the resistors inside the Wheatstone bridge cannot be fully matched. Those two imperfections lead to interference signals that are 60 dB larger than the resonator displacement signal. Furthermore, they are difficult to filter out by conventional filtering techniques in this frequency-tracking application. In this study, we proposed a natural frequency tracking algorithm to solve above problems. We first verify the stability and feasibility of the algorithm using Matlab/ Simulink. And then, we use one development board to emulate the dynamics of the resonator with imperfections, and one development board to realize the frequency tracking algorithms. Finally, we use this two development boards to complete the Hardware-in-the-Loop test for the proposed algorithm.
The experimental data indicates that the proposed method can successfully track the natural frequency of the system when large disturbance signals exist. When the natural frequency of the resonator is set for 92 kHz, 95 kHz, and 98 kHz, the proposed method can lock on to the frequency at 90.3kHz, 93.7kHz, and 96.5kHz, respectively.