A Measurement of Temperature Gradient of Flip-chip Bonding Structure Using in-situ Electrical Measurement System in Conjunction with Pt Thin-film Electrodes
摘要
This study utilizes an in-situ electrical measurement system containing the platinum (Pt) thin-film electrodes as the heater and temperature sensor to measure the temperature gradient (TG) values of flip-chip (FC) bonding structures. The threshold TG to ignite the thermomigration (TM) in FC structure was also evaluated by such a method. Since sample heating altered the resistance of Pt layer, consequently affecting the value of temperature coefficient of resistance (TCR) and the accuracy of temperature measurement. This study hence investigates the preparation of Pt layer with stable TCR property and finds that it can be accomplished via a 300C annealing for 20 hrs. Scanning electron microscopy (SEM) found insignificant change of the grain size of Pt layers, implying that the elimination of internal stresses and line defects provides the stable TCR property of Pt layers.
Afterward, the TG values of FC structures containing various solder bump arrays were measured. It was found that the TG value decreases dramatically with the increasing numbers of solder bumps. Previous studies often utilized the FC structure models containing single solder bump; however, in practice FC structures often contain arrays of solder bumps. Hence, the TG values of practical FC structures should be lower than that of FC structure with single solder bump. This study also found the insertion of underfill decreases the TG value of FC structure. This is ascribed to the change of heat transfer mode from radiation to conduction, which would further suppress the TG values.
The influence of thermal boundary resistance (RTBR) to TG values of FC structures with various solder bump densities and hights was also analyzed. The RTBR property exhibited insignficant effect on the TG values of FC structures with high solder bump densities. However, the influence of RTBR property on the TG values may be amplified with the decrease of hights.
Finally, the TM experiment at the TG of 600C/cm for 96 hrs was carried out in FC structure samples and composition changes of solder bumps were examined by SEM and energy-dispersive x-ray spectroscopy. Since no obvious composition and microstructure change was observed, the thershold TG value to ignite the TM failure in solder joints of FC structures hence should exceed 600C/cm.
Afterward, the TG values of FC structures containing various solder bump arrays were measured. It was found that the TG value decreases dramatically with the increasing numbers of solder bumps. Previous studies often utilized the FC structure models containing single solder bump; however, in practice FC structures often contain arrays of solder bumps. Hence, the TG values of practical FC structures should be lower than that of FC structure with single solder bump. This study also found the insertion of underfill decreases the TG value of FC structure. This is ascribed to the change of heat transfer mode from radiation to conduction, which would further suppress the TG values.
The influence of thermal boundary resistance (RTBR) to TG values of FC structures with various solder bump densities and hights was also analyzed. The RTBR property exhibited insignficant effect on the TG values of FC structures with high solder bump densities. However, the influence of RTBR property on the TG values may be amplified with the decrease of hights.
Finally, the TM experiment at the TG of 600C/cm for 96 hrs was carried out in FC structure samples and composition changes of solder bumps were examined by SEM and energy-dispersive x-ray spectroscopy. Since no obvious composition and microstructure change was observed, the thershold TG value to ignite the TM failure in solder joints of FC structures hence should exceed 600C/cm.
本研究以即時電性量測系統量測覆晶接合(Flip-chip Bonding,FC)結構之溫度梯度(Temperature gradient,TG),並使用此方法探討FC結構發生熱遷移(Thermomigration,TM)之臨界TG值。即時電性量測系統使用白金(Platinum,Pt)薄膜電極做為加熱器與測溫器,但加熱過程中的溫度變化影響Pt薄膜的電阻值,從而影響Pt薄膜之電阻溫度係數(Temperature Coefficient of Resistance,TCR)值,這會造成Pt薄膜電極溫度量測的誤差,故本研究首先尋找具備穩定TCR特性的Pt電極製作方法。實驗結果顯示,施予300C、20小時之熱處理可獲得相對穩定TCR特性的Pt電極。掃描式電子顯微鏡對Pt薄膜晶粒形貌的觀察顯示熱處理對晶粒尺寸影響甚微,推論熱處理主要消弭Pt薄膜之內應力與線缺陷而使TCR值趨於穩定。
本研究接著量測不同錫球密度的FC結構試片之TG值,實驗結果顯示,TG值隨著錫球密度增加而大幅下降,既往研究使用的FC試片模型大多僅含一個錫球,而實際FC試片皆含一定接合凸塊數量的錫球陣列,其TG值應低於既往研究報導之數值,高錫球密度的FC試片欲達成1000°C/cm的TG值應為難事。
本研究亦將TG量測結果與先期研究計算之結果比較,先期研究與本研究之計算結果均顯示TG值隨錫球陣列數之增加而降低。填入UF膠材的FC試片TG值較無填入UF膠材的試片更低,推論應為填入UF膠材會將熱傳導模式由輻射改變為傳導之故。UF膠材能將熱傳導模式從輻射轉為傳導使TG值降低,欲於含UF膠材的試片中建立高TG值環境更為不易。
本研究亦考慮界面熱阻(Thermal Boundary Resistance,RTBR)對於TG量測的影響,並比較RTBR對不同錫球密度與不同高度試片的TG值量測的影響。結果顯RTBR效應於對高Vf值的試片TG值的影響甚小,而RTBR效應對TG值的影響會因試片間隙高度減低而被放大。
本研究最後以600°C/cm之TG值對FC結構試片進行96小時之TM實驗,以能量分散X光光譜儀分析錫球之成分變化發現TM實驗並未明顯改變錫球之成份分布,對微觀結構變化亦不明顯,故推測發生TM破壞之臨界TG值應大於600°C/cm。
本研究接著量測不同錫球密度的FC結構試片之TG值,實驗結果顯示,TG值隨著錫球密度增加而大幅下降,既往研究使用的FC試片模型大多僅含一個錫球,而實際FC試片皆含一定接合凸塊數量的錫球陣列,其TG值應低於既往研究報導之數值,高錫球密度的FC試片欲達成1000°C/cm的TG值應為難事。
本研究亦將TG量測結果與先期研究計算之結果比較,先期研究與本研究之計算結果均顯示TG值隨錫球陣列數之增加而降低。填入UF膠材的FC試片TG值較無填入UF膠材的試片更低,推論應為填入UF膠材會將熱傳導模式由輻射改變為傳導之故。UF膠材能將熱傳導模式從輻射轉為傳導使TG值降低,欲於含UF膠材的試片中建立高TG值環境更為不易。
本研究亦考慮界面熱阻(Thermal Boundary Resistance,RTBR)對於TG量測的影響,並比較RTBR對不同錫球密度與不同高度試片的TG值量測的影響。結果顯RTBR效應於對高Vf值的試片TG值的影響甚小,而RTBR效應對TG值的影響會因試片間隙高度減低而被放大。
本研究最後以600°C/cm之TG值對FC結構試片進行96小時之TM實驗,以能量分散X光光譜儀分析錫球之成分變化發現TM實驗並未明顯改變錫球之成份分布,對微觀結構變化亦不明顯,故推測發生TM破壞之臨界TG值應大於600°C/cm。