開發新型電極搭載微流道用於細菌檢測和藥物遞送
顯示簡易詮釋資料 統計資料| 欄位 | 內容 | 語言 |
|---|---|---|
dc.contributor.advisor |
林子恩 | |
dc.contributor.advisor |
Lin, Tzu-En | |
dc.contributor.author |
林宜鴻 | |
dc.contributor.author |
Lin, Yi-Hong | |
dc.contributor.college |
電機學院 | |
dc.contributor.committee |
鄭兆珉 | |
dc.contributor.committee |
林頌然 | |
dc.contributor.committee |
Zheng, Chao-Min | |
dc.contributor.committee |
Lin, Sung-Jan | |
dc.contributor.department |
生醫工程研究所 | |
dc.contributor.studentid |
310515016 | |
dc.date.NCLavailable |
不公開 | |
dc.date.USTavailable |
不公開 | |
dc.date.etdavailablereason |
申請專利準備中 | |
dc.date.issued |
2023 | |
dc.date.issuedROC |
112 | |
dc.date.paperavailable |
2026/07/05 | |
dc.date.schoolyear |
111 | |
dc.description.abstract |
據報導,全球有近10億人患有急性和慢性傷口,這個龐大的病患量表示著巨大的財政支出。在發達國家,與慢性傷口管理相關的支出佔醫療保健總支出的比例高達3%。例如在美國,與慢性傷口相關的總費用約為每年500億美元。因此,需要更加有效的方法來提高皮膚傷口的治癒率,以降低相關費用支出。然而,慢性傷口感染的診斷並不是那麼簡單,尤其是壞死的軟組織容易感染,且進展為敗血症。更嚴重的是如果細菌經由血液循環散布到全身,造成全身性發炎反應,甚至可能會危及性命。因此,本研究的目的是希望在生物膜形成前,或是有肉眼還無法判斷的生物膜形成時,以掃描電化學顯微鏡(scanning electrochemical microscope, SECM)搭載微流道系統,利用實驗室開發的接觸式金軟電極結合微流道,作為一種具創新性且有效的檢測工具來精準的判斷是否有細菌汙染並給予藥物治療。首先我們先以二茂鐵甲醇(Ferrocenemethanol, FcMeOH)作氧化還原介質並掃描汙染了細菌的紗布並看其成像結果,也另外檢測了紗布和人造傷口上菌落的耗氧量,實驗結果顯示了乾淨的紗布和人造傷口對比受污染的紗布和人造傷口樣品電流值的差異。也因為確認是有差異,我們接續做了x line和成像的掃描。除了單純做檢測,我們也開發了微流道電極,目的是在SECM掃描後,可以即時的將藥物遞送至判定有細菌汙染的區域。微流道的製作是以PDMS為材料並以翻模的方式取得通道,並經過氧電漿的處理後使兩片PDMS完全接合,再與金軟電極做結合。以PDMS為材料去製作微流道是為了保留金軟電極其可彎曲且有彈性的特性。而在實際應用上,我們先是利用3D列印印製出架設微流道電極在SECM儀器上的裝置,接著使用微流道電極掃描判斷細菌存在的區域並去做藥物遞送,最後在藥物治療後再經由SECM掃描來判斷殺菌效果。根據實驗結果我們證實了微流道電極的可用性。 | |
dc.description.abstract |
The global prevalence of acute and chronic wounds is alarmingly high, affecting nearly 1 billion people and resulting in substantial financial burdens. In developed nations, expenses associated with the management of chronic wounds can account for up to 3% of total healthcare spending, with an estimated annual cost of approximately $50 billion in the United States alone. Consequently, there is an urgent demand for more efficient methods to improve skin wound healing rates and alleviate economic strain. However, diagnosing chronic wound infections is a complex task, particularly when necrotic soft tissues are susceptible to infection and can progress to sepsis. Furthermore, if bacteria spread throughout the body through the bloodstream, it can incite a systemic inflammatory response, posing a grave risk to the health and well-being of the patient. To address these challenges, this research endeavors to employ scanning electrochemical microscopy (SECM) in conjunction with a microfluidic system, incorporating a newly developed contact-mode soft gold electrode integrated within the microfluidic platform. This innovative and effective detection tool aims to accurately identify the presence of bacterial contamination and facilitate timely drug administration before biofilm formation or during the initial stages, which are imperceptible to the naked eye. Initially, ferrocenemethanol (FcMeOH) electrolyte was utilized to scan bacteria-contaminated gauze, enabling observation of the imaging results. In addition, the oxygen consumption of the bacterial colonies in the gauze and artificial wound samples was quantified. Experimental findings revealed distinguishable current discrepancies between uncontaminated samples and those contaminated with bacteria. Building upon this confirmed differentiation, further x-line and imaging scanning were conducted. In addition to enabling straightforward detection, microfluidic electrodes were developed to facilitate drug delivery to identified regions harboring bacterial contamination immediately after SECM scanning. The fabrication of microfluidics employed polydimethylsiloxane (PDMS) as the material, with channels accurately formed via molding. Oxygen plasma treatment facilitated seamless bonding of two PDMS components, which were subsequently integrated with the soft gold electrode. Employing PDMS in the microfluidic fabrication process was intended to preserve the flexible and elastic properties of the gold electrode. Practical implementation involved 3D printing a device capable of mounting the microfluidic electrode onto the SECM instrument. Subsequently, the microfluidic electrode was employed for scanning and identification of bacterial presence, followed by targeted drug delivery to these regions. Finally, SECM scanning was performed to assess the bactericidal efficacy after treatment. Based on the experimental outcomes, the feasibility of the microfluidic electrode was affirmed. | |
dc.description.abstractopendate |
2023/07/06 | |
dc.description.degree |
碩士 | |
dc.description.tableofcontents |
中文摘要i英文摘要ii圖目錄vi表目錄vii第一章 簡介11-1背景與動機11-2掃描式電化學顯微鏡的介紹11-2-1操作原理與組成元件31-2-2 SECM 操作模式41-2-3探針61-3文獻中SECM於細菌檢測之應用81-3-1細菌耗氧量測定91-3-2金屬離子與細菌相互作用的測量101-3-3過氧化氫的檢測111-3-4 pH值和ROS的檢測121-3-5群體感應的研究131-4 SECM的限制與展望141-5大腸桿菌介紹151-6綠膿桿菌介紹151-7金黃色葡萄球菌介紹161-8敷料介紹和選用紗布原由161-9急性和慢性傷口感染細菌181-10實驗大綱19第二章 材料與方法202.1化學藥品與材料202.2實驗設備及儀器202.3可撓式金軟電極212.4 微流道製作222.5微流道電極製作232.6實驗方法242-6-1細菌培養242-6-2紗布養菌252-6-3人造傷口處理252-6-4 FcMeOH電解液中掃描樣品表徵272-6-5細菌的耗氧檢測272-6-6綠膿素檢測272-6-7微流道藥物遞送28第三章 結果與討論293-1利用SECM檢測敷料與FcMeOH的氧化還原293-2利用SECM檢測敷料上細菌的呼吸作用313-3汙染細菌的敷料和乾淨敷料氧氣消耗的比較323-4利用SECM偵測在敷料上行呼吸作用的細菌353-5利用SECM檢測人造傷口上細菌之呼吸作用383-6汙染細菌的人造傷口和乾淨的豬皮氧氣消耗的比較393-7綠膿菌素的檢測413-8檢測病人傷口敷料上的細菌423-9微流道電極的製作453-10微流道電極的測試與耐受性463-11流速與擺放角度的選擇473-12架設微流道電極至SECM裝置493-13掃描汙染敷料後利用微流道遞送藥物493-14掃描豬眼球後利用微流道遞送藥物52第四章 結論與未來展望53參考資料54 | |
dc.identifier.citation |
1.Q. Yang et al., “Development of a novel ex vivo porcine skin explant model for the assessment of mature bacterial biofilms,” Wound Repair and Regeneration, vol. 21, no. 5, pp. 704–714, 2013, doi: 10.1111/wrr.12074.2.J. L. Connell, J. Kim, J. B. Shear, A. J. Bard, and M. Whiteley, “Real-time monitoring of quorum sensing in 3D-printed bacterial aggregates using scanning electrochemical microscopy,” Proceedings of the National Academy of Sciences, vol. 111, no. 51, pp. 18255–18260, Dec. 2014, doi: 10.1073/pnas.1421211111.3.G. Han and R. Ceilley, “Chronic Wound Healing: A Review of Current Management and Treatments,” Adv Ther, vol. 34, no. 3, pp. 599–610, Mar. 2017, doi: 10.1007/s12325-017-0478-y. | |
dc.identifier.uri |
https://hdl.handle.net/20.500.14371/82913 | |
dc.language.iso |
中文 | |
dc.relation.alma |
990053424570206772 | |
dc.relation.page |
66 | |
dc.subject.keyword |
掃描電化學顯微鏡 | |
dc.subject.keyword |
微流道 | |
dc.subject.keyword |
傷口敷料 | |
dc.subject.keyword |
人造傷口 | |
dc.subject.keyword |
SECM | |
dc.subject.keyword |
Microfluidic | |
dc.subject.keyword |
Wound Dressing | |
dc.subject.keyword |
Artificial Wound | |
dc.title |
開發新型電極搭載微流道用於細菌檢測和藥物遞送 | zh-TW |
dc.title |
Development of an Innovative Electrode-Microchannel Integration for Bacterial Detection and Drug Delivery | en |
dc.type |
Thesis | zh-TW |
檔案
全文未公開。
所屬典藏: 生醫工程研究所