鄰苯二甲酸二(2-乙基己基)酯量子點感測系統建立
Development of a quantum-dot sensing system for di(2-ethylhexyl)phthalate detection
摘要
本研究針對鄰苯二甲酸二(2-乙基己基)酯(di(2-ethylhexyl)phthalate, DEHP)結合分散型固相萃取與量子點探針發展快速簡便且具高靈敏度的DEHP感測系統。固相萃取中的高分子吸附材以甲基丙烯酸(Methacrylic acid, MAA)與苯乙烯(Styrene)為單體,乙二醇二甲基丙烯酸酯(Ethylene Glycol Dimethacrylate, EGDMA)為交聯劑製備之,高分子中自組裝形成的微網篩(micro-meshes)對DEHP有高吸附力,對DEHP之最大吸附量(qm)可高達36.8 mg/g,Langmuir吸附常數(KL)為0.171 L/mg。最佳化的固相萃取條件為10 mg吸附劑分散於10 ml水樣,吸附30分鐘後以6.0 ml甲苯為萃取溶劑脫附10分鐘,萃取回收率可達101.8%、RSD為4.9%,濃縮倍率為10倍。感測方面以硒化鎘量子點(CdSe quantum dots, CdSe QDs)為螢光探針,以苯甲酸作為DEHP的接受器(receptor),製備時在覆蓋劑苯甲酸:油酸為1.7:0.3 mmol比例下之CdSe QDs有最好的感測能力,其對DEHP的響應時間為10分鐘,且感測機制為光誘導電子轉移(photoinduced electron transfer, PET)造成螢光淬滅。分散型固相萃取結合CdSe QDs對DEHP的檢測範圍可廣及1.010-3 -3.0 mg/L,低濃度(1.010-3-1.010-2 mg/L)檢量線為y=1.2x0.63, R2=0.998,而高濃度(1.010-2-3.0 mg/L)檢量線為y=0.35x+0.077, R2=0.994,x與y分別為DEHP濃度(mg/L)與螢光淬滅程度(F0/F-1),偵測極限(limit of detection, LOD)為0.83 μg/L,於飲用水及瓶裝水分析的LOD與去離子水相當,於牛奶分析之LOD為1.19 μg/L,均低於美國國家環境保護局及歐盟限制之飲用水標準6 μg/L與1.3 μg/L。
In this study, a sensing system combining optimized dispersive solid-phase extraction (dSPE) and CdSe-quantum-dot (CdSe QDs) probes was developed for fast, highly sensitive, and selective detection of di(2-ethylhexyl)phthalate (DEHP). The polymeric adsorption material in dSPE was prepared with methacrylic acid (MAA) and styrene as monomers and ethylene glycol dimethacrylate (EGDMA) as a crosslinker. Micro-meshes formed in the crosslinked polymer contributed to a high and selective adsorption for DEHP with the maximum adsorption capacity (qm) of 36.8 mg/g and the Langmuir adsorption constant (KL) of 0.171 L/mg. The optimal dSPE conditions involved dispersing 10 mg adsorbent in 10 ml water sample. After 30 min adsorption, the adsorbed DEHP was eluted by 6.0 ml toluene for 10 min. The extraction recovery of 101.8% was achieved with an RSD of 4.9% and an enrichment factor of 10. The CdSe QDs prepared with benzoic acid and oleic acid as the receptor and the capping agent, respectively, at a molar ratio of 1.7-to-0.3, quickly responded to DEHP in 10 min via fluorescence quenching caused by photoinduced electron transfer (PET). The sensing system performed a wide dynamic range over 1.0×10-3 to 3.0 mg/L with two calibration dependencies. The calibration curve was expressed as y=1.2x0.63 with an R2 value of 0.998 over 1.0×10-3 to 1.0×10-2 mg/L, and it was y=0.35x+0.077 with an R2 value of 0.994 over 1.0×10-2 to 3.0 mg/L, where the x and y represent the DEHP concentration (mg/L) and the fluorescence quenching (F0/F-1), respectively. The limit of detection (LOD) in DI, drinking, and bottled waters was 0.83 μg/L, and it was 1.19 μg/L in milk samples. These values were below the water quality standards for DEHP set by USEPA (6 μg/L) and EU (1.3 μg/L).