三氧化硫相轉換行為研究及其在準確採樣上的應用
Study on the Phase Transition Behavior of Sulfur Trioxide and Its Application in Accurate Sampling.
摘要
本研究旨在探討三氧化硫於中低濃度(1–3 ppmv)及不同水氣條件(2–8 %v/v)下之氣液相轉化行為,評估其對煙道腐蝕與污染控制設備穩定性的潛在影響。雖SO₃於煙道中的濃度不高,但與水氣反應生成氣態硫酸,在煙氣冷卻至低於酸露點(Acid Dew Point, ADP)時即會凝結為液態硫酸,造成煙道內部腐蝕、孔蝕及下游觸媒中毒等問題。
本研究架設可穩定產生SO₃並控制水氣與溫度的實驗設備,搭配多孔金屬片採樣器(PDS)與離子層析儀(IC)進行SO₃氣液相分離與定量分析,並結合Verhoff & Brancher酸露點預測模型,探討各條件下之相轉化行為。結果顯示,在濕度2.06 %、3.34 %、4.01 %、6.27 %與8.06 %v/v下,SO₃實測氣液態比例在低於ADP時完全轉化為液態,高於ADP時誤差小於4 %,與ADP相近時預測值誤差約為10 %,顯示模型具良好準確性。
此外,研究中發現,若採樣時採樣器中部分溫度低於ADP,氣態SO₃可能在通過採樣器過程中凝結為液態硫酸,導致誤判相態與低估氣態濃度。為降低此誤差,建議採樣時應確認金屬片前實際溫度至少高於ADP 10 °C以上。另以乾燥氣體(0.00001 %v/v)作為背景時,ADP可降至6–19 °C,可避免氣液轉化,提升SO₃氣態穩定性與測定準確度。
本研究提出一套可用於中低濃度SO₃氣液行為評估與採樣條件設計的方法學,對於未來煙道腐蝕預測、環保採樣技術與污染控制系統優化,具有重要應用價值。
本研究架設可穩定產生SO₃並控制水氣與溫度的實驗設備,搭配多孔金屬片採樣器(PDS)與離子層析儀(IC)進行SO₃氣液相分離與定量分析,並結合Verhoff & Brancher酸露點預測模型,探討各條件下之相轉化行為。結果顯示,在濕度2.06 %、3.34 %、4.01 %、6.27 %與8.06 %v/v下,SO₃實測氣液態比例在低於ADP時完全轉化為液態,高於ADP時誤差小於4 %,與ADP相近時預測值誤差約為10 %,顯示模型具良好準確性。
此外,研究中發現,若採樣時採樣器中部分溫度低於ADP,氣態SO₃可能在通過採樣器過程中凝結為液態硫酸,導致誤判相態與低估氣態濃度。為降低此誤差,建議採樣時應確認金屬片前實際溫度至少高於ADP 10 °C以上。另以乾燥氣體(0.00001 %v/v)作為背景時,ADP可降至6–19 °C,可避免氣液轉化,提升SO₃氣態穩定性與測定準確度。
本研究提出一套可用於中低濃度SO₃氣液行為評估與採樣條件設計的方法學,對於未來煙道腐蝕預測、環保採樣技術與污染控制系統優化,具有重要應用價值。
The objective of this study is to investigate the gas-liquid phase transformation behavior of sulfur trioxide (SO₃) at low to medium concentrations (1–3 ppmv) and under varying humidity conditions (2–8 %v/v). This research aims to assess the potential impact of SO₃ on flue gas corrosion and the stability of pollution control devices.
A specialized experimental setup was established to consistently generate SO₃ while controlling humidity and temperature. Gas-liquid separation and quantitative analysis were conducted using a porous metal plate sampler and ion chromatography (IC). Additionally, we applied the Verhoff & Brancher acid dew point prediction model to analyze phase transformation behavior under the specified conditions. The results showed that at humidity levels between 2.06 % and 8.06 %v/v, the measured gas-liquid ratio of SO₃ transitioned to the liquid phase below the Acid Dew Point (ADP). Above the ADP, measurement errors remained under 4 %, with predicted values showing a deviation of approximately 10 % near the ADP.
Notably, it was found that if any component of the PDS is located below the ADP during sampling, gaseous SO₃ may condense into liquid sulfuric acid, leading to misrepresentation of its phase state. To minimize this error, it is suggested that the sampling temperature must be maintained at least 10 °C above the ADP. Furthermore, using dry gas (0.00001 %v/v) can reduce the ADP to 6-19 °C, helping to prevent gas-liquid transformation and enhance the accuracy of SO₃ gas measurements.
This study offers a framework for evaluating the gas-liquid behavior of SO₃ and optimizing sampling conditions for future assessments of flue gas corrosion and environmental monitoring.
A specialized experimental setup was established to consistently generate SO₃ while controlling humidity and temperature. Gas-liquid separation and quantitative analysis were conducted using a porous metal plate sampler and ion chromatography (IC). Additionally, we applied the Verhoff & Brancher acid dew point prediction model to analyze phase transformation behavior under the specified conditions. The results showed that at humidity levels between 2.06 % and 8.06 %v/v, the measured gas-liquid ratio of SO₃ transitioned to the liquid phase below the Acid Dew Point (ADP). Above the ADP, measurement errors remained under 4 %, with predicted values showing a deviation of approximately 10 % near the ADP.
Notably, it was found that if any component of the PDS is located below the ADP during sampling, gaseous SO₃ may condense into liquid sulfuric acid, leading to misrepresentation of its phase state. To minimize this error, it is suggested that the sampling temperature must be maintained at least 10 °C above the ADP. Furthermore, using dry gas (0.00001 %v/v) can reduce the ADP to 6-19 °C, helping to prevent gas-liquid transformation and enhance the accuracy of SO₃ gas measurements.
This study offers a framework for evaluating the gas-liquid behavior of SO₃ and optimizing sampling conditions for future assessments of flue gas corrosion and environmental monitoring.